Havit Lighting HV1847 Split Inground Light Installation Guide
- June 5, 2024
- Havit Lighting
Table of Contents
**Split Inground Light Installation Instructions**
Product Specifications
Model No.| HV1847W| I HV1847C
Name| Split
Material| 316 Stainless Steel Cover + Aluminium Body
Colour| Cover – Stainless Steel I Body – Black
IP Rating| IP67
Input Voltage| 12v DC
Protection Class| (Low Voltage)
Lamp Base| Built In LED
Lamp Wattage| 1 x 24w
Colour Temp| 3000k| 5500k
Lumens| 16001m| 19001m
CRI| > 80
Wiring| Parallel
Dimmable| No
Warranty| 3 Years Replacement*
Dimensions| Adequate Drainage
---|---
|
Important Safety Issues:
- This product must be installed by a qualified electrician according to AS/NZS 3000.
- Ensure all electrical mains are disconnected before any installation.
- Modification of this product will void any warranty.
- Havit Lighting does not take responsibility for wrong installation, incorrect use, or use of installation material that does not belong to the system.
- When installing low voltage fittings, the Voltage to fitting must be within +or- 5% of the voltage required, if not within this allowance warranty will be voided.
- Aluminum and 304SS fittings must not be installed within 5km of any saltwater environments.
- All 316 stainless steel fittings must have regular cleaning maintenance to avoid any tea staining from forming on the fitting. (Warranty does not cover Tea Staining)
- All o-rings and seals must be in place correctly to maintain a warranty
- When installing inground light fittings, Adequate drainage must be allowed to prevent fittings from sitting in water for a long period of time, if no drainage is allowed, the Warranty will be voided, See sample adequate drainage diagram for correct installation method.
- This form may be updated at any time due to product improvements, please check the online installation form for the most current version.
Steps for Installation:
- Make sure that the electrical circuit is free of voltage (master switch off)
- Make a hole where the fitting is to be placed using dimensions provided on line drawings, making sure adequate drainage is allowed.
- Insert the canister, and ensure that the top is level with the ground or floor. Failure to do so will void the warranty.
- Using an appropriate 12v DC LED Driver – DO NOT CONNECT LIGHT FITTING DIRECTLY TO 240V
- Connect the cable – If more than one fitting is installed, wiring must be done in parallel.
- Strip back the cable on both fitting and cable run and twist the positive cables together. Then connect neutral cables together
- Solder all joins using solder and either a heat gun or butane gas torch.
- Cover connections using an adhesive-lined heat shrink or gel cap to make the connection watertight. Failure to do this will void the warranty.
- Heat the heat shrink or crimp the gel cap making sure all connections are covered.
- Make sure the seals are still in place and screws are tight to avoid any water penetration.
- Insert fitting into the canister.
- Apply silicon around edge of the fitting to prevent any water from getting inside to electrical connections.
- All connections must be carried out carefully, inspect all contacts before switching back on the electric circuit.
Steps for Installation: HV1847-F-SH
- Remove nuts on the back of fitting and set aside
- Remove cover and replace with security face
- Reattach nuts and tighten making sure seals are still in place
- Insert fitting into the canister
- Insert screws and tighten
**Warranty Terms & Conditions*** | Additional Information |
---|---|
![Havit Lighting HV1847 Split Inground Light - qr 1](https://manuals.plus |
/wp-content/uploads/2022/07/Havit-Lighting-HV1847-Split-Inground-Light-
qr-1.png)
https://havit.com.au/pages/warranty-terms-and-conditions|
https://havit.com.au/
Must be installed by a licensed electrician
Contact Details:
143 Beauchamp Road Matraville NSW 2036 Australia
Tel: 02 9381 8300
Fax: 02 9666 8881
Email: sales@havit.com.au
Web: www.havit.com.au
Read User Manual Online (PDF format)