HAVIT Lighting Maxi 600 Bollard Light Instruction Manual
- June 4, 2024
- Havit Lighting
Table of Contents
HAVIT Lighting Maxi 600 Bollard Light
Product Specifications
Model No.| HV1606T-BLK-12V| HV1606T-SS316-12V| HV1616T-BLK-12V| HV1616T-
SS316-12V
---|---|---|---|---
Name| Maxi 600
Material| 316 Stainless Steel
Colour| Black| Stainless Steel| Black| Stainless Steel
IP Rating| IP54
Input Voltage| 12v DC
Lamp Base| MR16
Lamp Wattage| 1x 5w
Colour Temp| TRI Colour – 3000k, 4000k, 5500k
Lumens| 270lm, 285lm, 300lm
CRI| > 80
Wiring| Parallel
Dimmable| No
Warranty| 2 Years Replacement*
Mounting Base
Important Safety Issues
- This product must be installed by a qualified electrician according to AS/NZS 3000.
- Ensure all electrical mains are disconnected before any installation.
- Do not exceed maximum wattage restrictions for globes: 240V GU10 = 35w / 12V MR16 = 20w
- Modification of this product will void any warranty.
- Havit Lighting does not take responsibility for wrong installation, incorrect use, or use of installation material that does not belong to the system.
- When installing low voltage fittings, Voltage to fitting must be within +or- 5% of voltage required and cannot be installed more than 25m from LED Driver, if not within this allowance warranty will be voided.
- Aluminium and 304SS fittings must not be installed within 2km of any salt water environments.
- When installing copper fittings, gloves must be worn to avoid any oils transferring to fitting.
- All 316 stainless steel fittings must have regular cleaning maintenance to avoid any tea staining from forming on fitting. (Warranty does not cover Tea Staining)
- When installing surface-mounted bollards, base plate must be installed on concrete or concrete pad, Fitting should not be installed underground level, all holes including cable entry must be silliconed to prevent any water pentration into fitting, silicon must also be applied around fitting at ground level. Failure to do this will void the warranty.
- All o-rings and seals must be in place correctly to maintain warranty.
- These instructions may be updated at any time due to product improvements, Please visit the website for most current installation instructions.
Dimensions
Steps for Installation
- Make sure that the electrical circuit is free of voltage (master switch off).
- Remove 4x allen screws from side of fitting and put aside
- Install baseplate in desired location using apropriate screws for application. The screws supplied are mild steel which must be replaced with higher grade if there is any chance of them being affected by water. The location of baseplate must be installed on either concrete or concrete base and cannot be installed underground level.
- Locate IP rated junction box within the fitting. Undo the screws from the junction box and remove cover.
- Insert cable through cable gland on junction box. If your cable is not circular you must fix entry of your cable to maintain IP rating. Failure to do so will void the warranty.
- Using an appropriate 12V DC LED driver – DO NOT CONNECT FITTING DIRECTLY TO 240V
- Connect live and neutral wires. If more than one fitting is installed, wiring must be done in parallel.
- Reattach cover to IP rated junction box making sure screws are tight and seals are still in place.
- Silicon all cable entry holes and fixing points on the baseplate to avoid moisture penetration into fitting.
- Place bollard onto base plate and reattach 4x allen screws set aside earlier
- Colour temperature is set to 3000K. To change, remove cover from fitting by twisting anti-clockwise. for HV1606 models, remove the 2x nuts and washers and put aside Remove the globe by also twisting anti clockwise and select desired colour temperature by moving switch on side of globe and then reinserting globe.
- Reattach cover by turning clockwise or for HV1606 Models, reattach the 2x nuts first, making sure the seals are still in place and cover is tight to avoid any water penetration.
- All connections must be carried out carefully, inspect all contacts before switching back on the electric circuit.
Steps for Changing Globe
- Remove cover from fitting by twisting anti clockwise. for HV1606 models, remove the 2x nuts and washers and put aside Remove globe by also twisting anti clockwise.
- Re-insert the appropriate globe by twisting clockwise into the lamp holder (Make sure not to exceed max wattage, see product label for correct info)
- Reattach cover by turning clockwise or for HV1606 Models, reattach the 2x nuts first, making sure the seals are still in place and the cover is tight to avoid any water penetration.
Must be installed by a licensed electrician
Contact Details
- ADDRESS: 143 Beauchamp Road Matraville NSW 2036 Australia
- Tel: 02 9381 8300
- Fax: 02 9666 8881
- Email: sales@havit.com.au
- Web: www.havit.com.au
Warranty Terms & Conditions
Additional Information
Documents / Resources
|
HAVIT Lighting Maxi 600 Bollard
Light
[pdf] Instruction Manual
Maxi 600 Bollard Light, Maxi 600, Bollard Light, Maxi 600 Light, Light, Maxi
Light, 600 Light
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>