JBC P305 Pedal Kit for Control Units Instruction Manual

June 5, 2024
JBC

JBC LOGOwww.jbctools.com
INSTRUCTION MANUALJBC P305 Pedal Kit for Control
Units P305
Pedal Kit for Control Units

This manual corresponds to the following references:
P-305

Packing List

The following items are included:

| |
---|---|---
Pedal …………………………………………………….1 unit| Adapter …………………………………………………1 unit| Manual ……………………………………………. 1 unit
Ref. 0028918

Connection Example
Connect the tool stand and the pedal to the adapter. Then connect the adapter to the station port.JBC P305 Pedal Kit for Control Units - Connection
Examp

Pedal Compatibility

P305 is compatible with JBC devices as shown in the table in the highlighted column.
P405 and P005 is also shown in the table below.
Marked with means pedal P405/P005 cannot be connected directly to JBCs control unit. A module (MSE, MVE, MNE) must be used (See next page “Pedal Set Up”).

| Pedals
---|---
| P405| P305| P005
| DIU| | |
| DDU| | |
| DMU| | |
Control Unit| HDU| | |
JANU| | |
JTA| | |
WSU| | |
ALU| | |
NAU| | |
Station| AL| | |
Module| MSE| | |
MOVE| | |
MNE| | |
Preheater| PINK| | |
PHIL| | |
PHBK| | |
PHXK| | |
Fume
Extractor| FAE1| | |
FAE2| | |

Pedal Set Up for
130 mm
– DIU (Control Unit)
– WSU (Wire Stipper Station)
In order for the tool not to heat up the component before the pedal is pressed, the station’s Sleep
Delay and Hibernation Delay function must be set to 0 min.
Pedal Set Up P305

  1. Enter the Main Menu and select Tool Settings
  2. Change Sleep Delay and Hibernation Delay to 0 min.

Pedal Set Up for:
– DDU, HDU (Control Units)

Note: Peripheral module – MSE, MVE or MNE – are needed to connect the pedal to DDU y HDU.

  1. Enter the Peripherals Menu and select the port which you want to join to the pedal.JBC P305 Pedal Kit for Control Units - Select port

  2. Select the pedal from the list.
    JBC P305 Pedal Kit for Control Units - pedal

  3. Set the pedal function according to your work needs:JBC P305 Pedal Kit for Control Units - module

*NB: The same can be applied inversely by continually pressing the pedal and releasing to activate.

Pedal Set Up for DMU (Control Unit)

Note: Peripheral moduls – MSE, MVE or MNE – are needed to connect the pedal to DMU.
After connecting one of the mentioned moduls to the station a popup window opens.

  1. To configure the module MSE/MVE/MNE press Setup in the popup window.
    JBC P305 Pedal Kit for Control Units - window

  2. Select the module from the list of peripheral connections. Remember your first connection is denoted as “a”, the second being “b”, etc. (e.g. MS_a, MS_b,…). Do the same with the pedal (e.g.PD_a,…)

  3. Select the port of the tool you want to link to the peripheral.JBC P305 Pedal Kit for Control Units - peripheral

  4. Press Menu or Back to save changes.
    Once set up, the module settings can be changed by entering the Peripherals Menu.

Example:
Chip Components Rework Process using Tweezers and Pedal
The Pedal is frequently used to rework components with tweezers.
AN115 JBCs adjustable nano tweezers is the most effective tool for desoldering chip components but also it facilitates its rapid placement and soldering by using P405 pedal connected to JBC´s NAS station.JBC P305 Pedal Kit for
Control Units - Connections

Connections

Connect pedal P305 to its adapter and then the adapter to the control unit port. The tool must be connected to its sand and the stand to the pedal adapter.
In the peripherals menu for the “Pedal Activation Mode” choose between “pressed” and “released”.
Note: If working with P305 and its adapter, choose the pedal functionality at the adapter switch like shown beside.

  • “Press Mode” previously selected

**Desoldering***
Lift the tool from the holder, press and hold the pedal to activate the tool and desolder the component.
Once the pedal is released the tool enters in hibernation mode and cools down.JBC P305 Pedal Kit for Control Units - Pad
Cleaning

Pad Cleaning
Clean the pads with JBC´s desoldering tool DS360.
For this operation JBC´s desoldering station DSS is needed.

Solder Paste Dispensing
Apply the solder paste amount needed to solder the new chip component.
The use of JBC´s DPM solder paste dispenser is recommended.

JBC P305 Pedal Kit for Control Units - Placing| JBC P305 Pedal Kit for Control Units - pedal 1
---|---

Placing
Do not press the pedal.
Use the tool to position the component on the previously tinned pad.
Note: The inactive tool prevents the component from heating up prematurely.

JBC P305 Pedal Kit for Control Units - Soldering| JBC P305 Pedal Kit for Control Units - position
---|---

Soldering
Once in position press and hold the pedal to activate the tool and perform the soldering.

Notes

Specifications

P305
Pedal Kit for Control Units
Ref. P-305

– Pedal Cable Length: 1.9 m / 74.80 in
– Total Net Weight: 513 g / 1.13 lb
– Total Package Dimension / Weigt: 342 x 155 x 120 mm / 783 g
 (L x W x H) 13.46 x 6.10 x 4.72 in / 1.73 lb

Complies with CE standards ESD safe

JBC LOGO

Warranty
JBC’s 2-year warranty covers this equipment against all manufacturing defects, including the replacement of defective parts and labor.
The warranty does not cover product wear or misuse.
In order for the warranty to be valid, equipment must be returned, postage paid, to the dealer where it was purchased.

This product should not be thrown in the garbage.
In accordance with the European directive 2012/19/EU, electronic equipment at the end of its life must be collected and returned to an authorized recycling facility.

0028918-0522
www.jbctools.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals