SEALEY VEN200 Portable Ventilators Instructions
- June 5, 2024
- SEALEY
Table of Contents
SEALEY VEN200 Portable Ventilators
Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS, AND CAUTIONS. USE THIS PRODUCT CORRECTLY, AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY.
SAFETY INSTRUCTIONS
ELECTRICAL SAFETY
WARNING! It is the responsibility of the owner and the operator to read,
understand and comply with the following:
You must check all electrical products, before use, to ensure that they are
safe. You must inspect power cables, plugs, sockets and any other connectors
for wear or damage. You must ensure that the risk of electric shock is
minimised by the installation of appropriate safety devices. A Residual
Current Circuit Breaker (RCCB) should be incorporated in the main distribution
board. We also recommend that a Residual Current Device (RCD) is used. It is
particularly important to use an RCD with portable products that are plugged
into a supply which is not protected by an RCCB. If in any doubt consult a
qualified electrician. You may obtain a Residual Current Device by contacting
your Sealey dealer.
You must also read and understand the following instructions concerning
electrical safety.
-
The Electricity at Work Act 1989 requires that all portable electrical appliances, if used on business premises, are tested by a qualified electrician, using a Portable Appliance Tester (PAT), at least once a year.
-
The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances and the safety of the appliance operators. If in any doubt about electrical safety, contact a qualified electrician.
-
Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. See 1.1.1 and 1.1.2 and use a Portable Appliance Tester.
-
Ensure that cables are always protected against short circuit and overload.
-
Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that none is loose.
-
Important: Ensure that the voltage marked on the appliance matches the power supply to be used and that the plug is fitted with the correct fuse – see fuse rating at right.
-
DO NOT pull or carry the appliance by the power cable.
-
DO NOT pull the plug from the socket by the cable.
-
DO NOT use worn or damaged cables, plugs or connectors. Immediately have any faulty item repaired or replaced by a qualified electrician. When a BS 1363/A UK 3 pin plug is damaged, cut the cable just above the plug and dispose of the plug safely.
Fit a new plug according to the following instructions (UK only). -
Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.
-
Connect the BROWN live wire to the live terminal ‘L’.
-
Connect the BLUE neutral wire to the neutral terminal ‘N’.
-
After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer insulation extends beyond the cable restraint and that the restraint is tight. Double insulated products, which are always marked with this symbol , are fitted with live (brown) and neutral (blue) wires only. To rewire, connect the wires as indicated above – DO NOT connect either wire to the earth terminal.
-
Products which require more than 13 amps are supplied without a plug. In this case you must contact a qualified electrician to ensure that a suitably rated supply is available. We recommend that you discuss the installation of an industrial round pin plug and socket with your electrician.
-
If an extension reel is used it should be fully unwound before connection. A reel with an RCD fitted is preferred since any appliance plugged into it will be protected. The cable core section is important and should be at least 1.5mm², but to be absolutely sure that the capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the use of 2.5mm² section cable.
GENERAL SAFETY
- Disconnect the ventilator from the mains power when not in use, and before servicing or performing any maintenance.
- Use the fan in dry areas only. Do not use in wet or high condensation locations such as bathrooms, showers, or pools.
- WARNING! If a ventilator falls into water, immediately switch off at the mains and disconnect from the mains power supply. DO NOT touch the ventilator until the mains power supply has been disconnected.
- Always disconnect the ventilator from the power supply when moving it from one location to another.
- Keep the ventilator clean and maintain in good condition (use an authorised service agent).
- Use recommended parts only (un authorised parts may be dangerous, and will invalidate your warranty).
- DO NOT stand the ventilator where it may be knocked over or off a surface, or where the lead may cause a person to trip.
- DO NOT use an extension cord unless it has been approved by an electrical authority.
- DO NOT insert any objects through the fan guard.
- DO NOT allow children to operate the ventilator.
- DO NOT immerse the ventilator in water or any other liquid.
- DO NOT use the ventilator outdoors.
- When not in use store in a safe, dry, childproof location.
- DO NOT cover the ventilator.
INTRODUCTION & SPECIFICATIONS
Ideal for use where high volume air delivery is required. Especially suitable for ventilating confined, hot or fume laden work sites, typically as found in boats, cable/pipe ducts, roof spaces etc. Light weight and robust construction give the portability and durability necessary in the work place. Fitted with carry handle, 2.4mtr cable and ASTA/BS approved plug. Supplied with 5mtr ducting.
Model No:…………………………………… EN200
Supply:…………………………………… 230V 1ph
Motor:………………………………………….. 180W
Fan Diameter:…………………………….. 200mm
| Fan Speed:………………………………. 2800rpm
Air Flow:………………………………….. 25m³/min
Static Pressure:…………………………. 2.4mbar
Weight (without ducting):…………………. 7.4kg
| Additional Ducting (5mtr):……….. EN200AK1
Additional Ducting (10mtr):………. EN200AK2
Note: Maximum length 10mtr
---|---|---
Model No:…………………………………… EN300
Supply:…………………………………… 230V 1ph
Motor:………………………………………….. 520W
Fan Diameter:…………………………….. 300mm
| Fan Speed:………………………………. 2800rpm
Air Flow:………………………………….. 60m³/min
Static Pressure:…………………………. 3.4mbar
Weight (without ducting):……………….. 11.7kg
| Additional Ducting (5mtr):……….. EN300AK1
Additional Ducting (10mtr):………. EN300AK2
Note: Maximum length 10mtr
ASSEMBLY
AIR DUCTING
- The ducting can be used to either suck the air from an area or blow air into an area.
- To extract air from an area attach the ducting (fig 1) to the inlet. Place the other end of the ducting into the desired area.
- To blow air into an area, attach the ducting to the opposite end of the unit and locate the ducting in the area you wish to ventilate.
Note: The ducting has suspension eyes attached. These can be used to suspend the ducting if elevation is necessary to carry out the required ventilation
OPERATION
OPERATING THE UNIT
- Plug the mains socket into an adequate power supply.
- Use the toggle switch (fig 2) to start/stop the unit.
Declaration of Conformity
NOTE: It is our policy to continually improve products and as such we
reserve the right to alter data, specifications and component parts without
prior notice. IMPORTANT: No liability is accepted for incorrect use of
this equipment.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will
be required for any claim. INFORMATION: For a copy of our latest catalogue and
promotions call us on 01284 757525 and leave your full name and address,
including postcode
ABOUT COMPANY
- Sole UK Distributor, Sealey Group, Bury St. Edmunds, Suffolk
- TEL: 01284 757500
- FAX: 01284 703534
- WEB: www.sealey.co.uk
- E MAIL : sales@sealey.co.uk
Get In Touch
- Call: 0845 6880112
- Email: info@adremit.co.uk
Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard, Settle, North Yorkshire, BD24 9RH
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>