GUDE GS1102PI DIRTY-WATER SUBMERSIBLE PUMP Instructions
- June 5, 2024
- Gude
Table of Contents
GS1102PI DIRTY-WATER SUBMERSIBLE PUMP
Instructions
GS 1102 PI
**# 94634
**
Translation of original operating instructions
DIRTY-WATER SUBMERSIBLE PUMP
Please read carefully the following Operating Instructions before putting the
appliance into operation
A.V. 2 Any reprints, even partial, are subject to approval. Technical changes
reserved. Illustrative pictures! Translation of original operating
instructions.
Marking:
Product safety:
|
---|---
The product corresponds to appropriate norms of the European Community|
Prohibitions:
|
---|---
Staying in the transportation medium prohibited| Access to children prohibited
|
Cable pulling/transport prohibited| Transportation medium of max. 35 °C
Warning:
|
---|---
Warning against dangerous electric voltage| Warning against automatic starting
Commands:
****|
---|---
Read the Operating Instructions|
Environment protection:
|
---|---
Dispose of the waste professionally in order not to pollute the environment.|
Packing cardboard material may be delivered to collecting centers for
recycling.
|
Any damaged or disposed of electric or electronic devices must be delivered to
appropriate collection centers.|
Package:
|
---|---
Protect against humidity| This side up
Disposal
Disposal instructions are illustrated in the form of pictograms on the device
or packaging. A description of the pictograms is given in the “Identification”
chapter.
Disposal of transport packaging Packaging protects the device against damage
during transport. Packaging materials are usually selected according to their
effect on the environment and disposal methods and can therefore be recycled.
Returning the packaging back to circulation saves resources and costs for
packaging disposal. Parts of the packaging (e.g. foil, styropor) may be
dangerous for children. Risk of suffocation! Keep these parts of the packaging
out of reach of children and dispose of them as soon as possible.
Appliance
GS 1102 PI
Permanent use. Cable RNF 10 m long. Float automatics
Areas of Use: To pump/pump out water – clean and dirt – from sewers, tanks,
etc.
Supply includes (pic. A)
- Carrying handle
- Pump connection
- Electric cable
- Foot
- The connecting neck of the pump
- Floating switch
- Pump cover/body
Warranty
A warranty period of 12 months applies to commercial use and 24 months apply
to private use and commences on the day of purchase of the device.
Warranty applies exclusively to failures due to defective material or
workmanship. An original sale slip with an indication of the date of sale must
be presented in case of claiming the warranty rights.
The warranty does not cover unprofessional use such as device overload,
violent use, damage caused by a third party or foreign materials, failure to
comply with operations and assembly manual, and normal wear and tear.
General safety instructions
The Operating Instructions need to be read thoroughly before the first use of
the appliance. If there are any doubts concerning appliance connection and
handling, please contact the producer (service department).
TO ENSURE A HIGH SAFETY LEVEL, FOLLOW CAREFULLY THE FOLLOWING INSTRUCTIONS:
Attention: Operation is only allowed with a safety switch against stray
current (max. stray current of 30mA according to VDE regulation, part 702).
Please ask your electrician.
Attention: The pump must not in any case run without fillings. The pump must
work fully plunged in liquid.
- The user is responsible to third parties if a pump (dumping stations, etc.) is used.
- Operate it only on connections with a safety switch against stray current (FI)!
- Before putting it into operation, a qualified electrician must check whether the electric safety measures required are in place.
- Electric connection to a socket.
- Check the voltage. Technical data given on the type label must correspond with electric network voltage.
- If the pump is used in ponds, wells, etc., and appropriate pumping stations, standards valid for pumps in the given country must unconditionally be observed.
- Pumps used outdoors (e.g. in ponds, etc.) must be equipped with an H07RNF type rubber connecting cable, according to DIN 57282 or DIN 57245 standards.
- If the pump is in operation, neither people nor animals can be present or plunged in the pumped liquid (e.g. pools, cellars, etc.).
- The temperature of the drained liquid must not exceed +35 °C. If an extension cable is used, it must solely be out of rubber, H07RNF type, according to DIN 57282 or DIN 57245 standards. Never touch, lift or carry with a cable or a pump connected to the network. It is necessary to make sure the connecting socket was not near water and humidity and the plug was protected against humidity.
- Before putting the pump into operation, check whether the electric cable and/or socket are not damaged.
- Before any work on the pump, pull the plug out of the socket.
- If the pump is inbuilt in a floor outlet, the floor outlet must subsequently be covered to ensure the inviolability of passers-by.
- The connection of the discharge pipe needs to be ensured with a hose clip (pic. F).
- Keep the max. plunge depth (see the technical data). To prevent damage (such as flooded rooms, etc.) as a result of faulty pump operation (failure or fault) the owner (user)′s obliged to take reasonable safety measures (alarm assembly, spare pump, etc.).In sandy or muddy soils, it is necessary to let the pump run hanging on a rope or chains or at the pump on reasonable support to prevent the suction part from falling.
- If the pump is faulty, the repair needs to be solely executed by an authorized service center. Only original spare parts can be used.
- Let us refer to the fact we do not assume any responsibility – according to standards in force – for damage eventually caused by our appliances in the below-mentioned cases:
- Unprofessional repairs executed by unauthorized service centers;
- Use in conflict with the designed purpose, or failure to observe the use as designed;
- Pump overload with a continuous run;
- Damage as a result of icing or any other fault caused by climatic influences;
Identical regulations apply for accessory parts.
- At any damage to the power supply cable of the appliance, please unconditionally contact the electrician. Under no circumstances, execute any repair with your hands.
- This appliance is not designed to be used by persons (including children) with any bodily, sensory, or mental restriction. Also, persons with a lack of experience or knowledge of the appliance are not allowed to work with the appliance.
- Never let unauthorized and unattended persons, especially children, get near the appliance. Always keep children and unauthorized persons out of reach of the appliance.
The pump is not suitable for long-term operation (e.g. as a circulation pump
in ponds or brooks). The service life gets shorter accordingly if the pump is
used in this manner. In such a case, use a switching clock and ensure
sufficiently long breaks between the operating cycles.
The pump must not be connected to the existing water supply system as
equipment increases the pressure.
The pump is not suitable as a long-term, automatic safety against overflow of
tanks and wells or for control of underground water in cellars.
Do not leave the pump unattended to prevent damage as a result of any faulty
function. Always disconnect the pump from the network if not used.
The producer does not guarantee any damage caused by the unqualified
installation or unprofessional operation of the pump.
The equipment must be regularly inspected and its faultless condition needs to
be checked.
Before each putting into operation, the pump must be visually inspected for
any damage (especially on the power supply cable and plug). Using a damaged
pump is strictly prohibited.
Connecting cable for drowned pumps
The drowned pumps are equipped with a 10-m H07RNF cable, depending on the
type.
According to the valid regulation, drowned pumps with a connecting cable
length of fewer than 10 m can only be used indoors for water drainage from
cellars.
Therefore the cable length and type need to be considered at purchasing.
Thermal fuse
A probe automatically switches the pump off when a specific temperature is
exceeded and on when the pump has cooled down is assembled inside the electric
motor. That manifold increases the pump service life and prevents electric
motor burn-out.
Procedure:
The pump is put into operation when the plug is inserted in the appropriate
socket and the floating switch is in the required position (see the
Instructions). If the pump is lifted or transported, it is done with an
assembled handle and not with the connecting cable. If the pump is being
plunged, a rope, chain, etc. fastened to the handle needs to be used if
necessary.
In muddy, sandy, or siliceous soil the pump must be hung on a rope or chain or
put on a suitable wide baseplate to be able to work plunged. Sand and other
abrasive solids reduce the service life of hydraulic parts and the seal of the
pump and therefore they need to be prevented. In frost conditions, the pump
must be removed from the pumped liquid. It is necessary to absolutely make
sure the pump is not exposed to a risk of frost. The pump must be emptied and
stored at a place protected against frost.
Attention! Important information for the customer It is recommended to
plunge or put the pump sideways in the liquid. The body air cushion can thus
be released and the pump starts immediately working. The pump can subsequently
be stood straight.
Attention! Important information for the customer To ensure the long
service life of the pump seal, we recommend rinsing the pump with clean water
at regular intervals.
Automatic float
The float will automatically put the pump into operation when the liquid
level goes up or down. If the float cable is extended or shortened, based on
its support point, it will switch the pump on or off due to the minimum or
maximum height required. The floating cable is fixed to the pump handle with a
suitable pressure holder. Please check whether the float is moving freely at
pump operation. The pump must always be rinsed with clean water when used in
very dirty water. The switching on and off heights can differ.
Thermal fuse/engine protection circuit-breaker
The drowned pump is equipped with an engine protection circuit-breaker. If
the engine is overheated, the engine protection circuit-breaker will
automatically switch the pump off. Cooling time is app. 25 minutes, the pump
subsequently switches on. If the engine protection circuit-breaker switches
on, it is absolutely necessary to identify the cause and remove it (see also
the “Failure searching“). The given data cannot be used for “family style“
repairs as it requires specific professional knowledge. You must contact the
customer service department at any failures.
Residual risks and protective measures
Electric residual risks:
Threat | Description | Protective measure(s) |
---|---|---|
Direct electric contact | Electric shock | Safety switch against FI stray |
current
Indirect electric contact| Electric shock through the medium| Safety switch
against FI stray current
Requirements for operating staff
The operating staff must carefully read the Operating Instructions before
using the appliance.
Qualification
Apart from the detailed instructions by a professional, no special
qualification is necessary for appliance use.
Minimum age
Persons over 16 years of age can only work on the appliance.
An exception includes youngsters trained in order to reach knowledge under the
supervision of the trainer during occupational education.
Training
Using the appliance only requires corresponding training by a professional
or the Operating Instructions. No special training is necessary.
Technical data
| GS 1102 PI
---|---
Voltage/Frequency| 230 V / 50 Hz
Motor capacity P1| 1100 W
Maximum delivered quantity| 20000 l/h
Maximum head of delivery| 8 m
Maximum immersion| 7 m
Hose connection| 1 ½ ’’
Protection class| IPX8
Water temperature| 35 °C
Granulation| 35 mm
Max. suction| 6,4 kg
Weight ca| 94634
**Transport and storage
**
**** During winter storing, it is necessary to make sure there is no water in the appliance as the frost could damage the appliance.
Safety instructions for first putting into operation
Attention: The pump must not run without fillings.
The user is responsible to third parties if the pump (pumping station, etc.)
is used.
To be operated on connections with a safety switch against the stray
current (RCD) only!
Before putting it into operation, a competent electrician must check whether
electric safety devices are in place.
Electric connection to a socket.
Check the voltage. Technical data given on the type label must correspond with
electric network voltage.
If the pump is used in ponds, wells, etc., and appropriate pumping stations,
standards valid for pumps in the given country must unconditionally be
observed.
Electric pumps used outdoors (e.g. in ponds, etc.) must be equipped with an
H07RNF type rubber connecting cable, according to DIN 57282 or DIN 57245
standards.
- If the pump is in operation, neither people nor animals can be present or plunged in the pumped liquid (e.g. pools, cellars, etc.).
The temperature of the drained liquid must not exceed +35 °C. If an extension cable is used, it must solely be out of rubber, H07RNF type, according to DIN 57282 or DIN 57245 standards.
Never touch, lift or carry with a cable a pump connected to the network
(pic. E)
It is necessary to make sure the connecting socket was not near water and
humidity and the plug was protected against humidity.
Before putting the pump into operation, check whether the electric cable
and/or socket are not damaged.
Before any work on the pump, pull the plug out of the socket.
Emergency Action
Apply the first aid adequate to the injury and get qualified medical
assistance as quickly as possible. Protect the injured person from more
accidents and calm him/her down.
For the sake of eventual accident, in accordance with DIN 13164, a workplace
has to be fitted with a first-aid kit. It is essential to replace any used
material in the
first-aid kit immediately after it has been used. If you seek help, state the
following pieces of information:
- Accident site
- Accident type
- Number of injured persons
- Injury type(s)
Instructions step by step
- Connect the water hose to the appropriate pump outlet (see the Assembly and first put into operation).
- Fix the rope, chain, etc. to the pump handle and place it in the right place.
- Put the pump “sideways“ ( pic. D ) to the pumped medium. Make sure the floating switch is in the operating position.
- Plug in the pump.
- Rinse the pump with clean water after work finishing.
Floating switch positions (pic. B + C)
The operating or shutdown point of the pump can be set with various
floating switch positions. In pic. B you can see the float cable without any
fixation change with a full switch radius. Figure 1 is the working position
and figure 0 is the shutdown position.
Due to appropriate fixation of the float cable, possibly on the pump handle,
the switch radius can be reduced when there is no sufficient space or at a
corresponding level control. Figure 1 in the pic. C is the working position
and figure 0 is the shutdown position.
Failures – caused – removal
(problem): | The engine does not start |
---|---|
(cause): | 1. No system voltage |
2. Blocked pump wheel
3. Floating switch in shutdown position
(measures):| 1. Check the voltage
2. Inspect the pump wheel for foreign objects
3. Check the water level (pic. B/C)
(problem):| The pump does not suck
(cause):| 1. Pump without water
2. Water level too low
3. Blocked pump wheel
(measures):| 1. Let the air bubbles release (pic. D)
2. Switch the pump off, the water level must go up.
3. Remove the obstruction
(problem):| Insufficient amount of water pumped
(cause):| 1. Dirty tube filter
2. Water level quickly going down
3. Maximum head of delivery exceeded
4. Transport guide broken
(measures):| 1. Clean the tube filter
2. Ensure sufficient inflow
3. Check the transport path length
4. Check the transport guide
(problem):| Thermal detector switching the pump off
(cause):| 1. Dirty tube filter
2. Water temperature too high
3. Pump running continuously at
maximum pressure.
(measures):| 1. Clean the tube filter and let the
pump cool down
2. Reduce the water temperature
3. Make more breaks
**Inspections and maintenance
**
Except for the below-described cases, the pump must be delivered to the
customer service department for any repairs. Sand and other abrasive solids
cause premature wear and pump power reduction. Works on the pump electric
equipment can explicitly be executed by the customer service department only
(that also applies to the electric cable and float). The drowned sludge pumps
are virtually maintenance-free. Oilless bearings. Occasional filter support
cleaning is enough, no other maintenance is necessary. Original spare parts
must only be used in any case.
To ensure the long service life of the pump seal, we recommend rinsing the
pump with clean water at regular intervals.
Safety instructions for inspections and maintenance
It is always necessary to interrupt feeding (plug pulled out of the socket)
and make sure the pump is not going to start before any pump maintenance. Only
a regularly maintained and treated appliance can serve as a satisfactory aid.
Insufficient maintenance and care can lead to unforeseen accidents and
injuries.
Inspection and maintenance plan
Time interval | Description | Any other details |
---|---|---|
As needed | Cleaning and rinsing out |
Service
Any technical questions? Complaint? Do you need spare parts or an operation
manual?
Go to our website www.guede.com and the section
Service will help you quickly and without bureaucracy. Please, help us to help
you. In order to identify your device in case of
a complaint, please indicate the serial number, order number, and year of
manufacture. All information is available on the product label. To have all
information always at hand, put them down.
Serial number:……………..
Order number:…………….
Year of manufacture:…….
Phone: +49 (0) 79 04 / 700-360
Fax: +49 (0) 79 04 / 700-51999
E-Mail:support@ts.guede.com
Important information for the customer
Please be sure to know that returning the product in or after the warranty
period must be made in the original packaging.
Translation of the EC-Declaration of Conformity
We, hereby declare the conception and construction of the below-mentioned
appliances correspond – at the type of construction being launched – to the
appropriate basic safety and hygienic requirements of EC Directives. In case
of any change to the appliance not discussed with us, the Declaration expires.
Appropriate EU Directives 2006/95/EC
2006/95/EC
2009/105/EC
2011/65/EC ROHS
89/686/EEC (PPE)
2006/42/EC
– Annex IV
Notified Body
No: 0197
Name: TUV Rheinland LGA Products GmbH
Address: Tillystrasse 2
90431 Nürnberg Germany
Type Ex. Cert.-No.:
**97/68/EC_
Emission No.:
2000/14/EC_2005/88/EC| 2004/108/EC
1907/2006/EC
2009/142/EC
1935/2004/EC
**
---|---
Method of compliance assessment
Annex V
Harmonized standards used
EN 60335-1:2012
EN 60225-2-41:2003+A1+A2
EN 62233:2008; ZEK 01.4-08/11.11
EN 55014-1:2006+A1+A2
EN 55014-2:1997+A1+A2
EN 61000-3-2:2006+A1+A2
EN 61000-3-3:2013
Guaranteed sound power level
LWA dB(A)
Measured sound power level
LWA dB(A)
Wolpertshausen,
23.07.2015 Helmut Arnold
Managing Director
Joachim Bürkle
GÜDE GmbH & Co. KG, Birkichstraße 6, 74549 Wolpertshausen, Germany
Authorized to compile the technical file
GÜDE GmbH & Co. KG
Birkichstrasse 6
74549 Wolpertshausen
Deutschland
Tel.: +49-(0)7904/700-0
Fax.: +49-(0)7904/700-250
eMail: info@guede.com
www.guede.com
Documents / Resources
| GUDE
GS1102PI DIRTY-WATER SUBMERSIBLE
PUMP
[pdf] Instructions
GS1102PI DIRTY-WATER SUBMERSIBLE PUMP, DIRTY-WATER SUBMERSIBLE PUMP,
SUBMERSIBLE PUMP
---|---
| Gude
GS1102PI DIRTY-WATER SUBMERSIBLE
PUMP
[pdf] Instructions
GS1102PI DIRTY-WATER SUBMERSIBLE PUMP, DIRTY-WATER SUBMERSIBLE PUMP,
SUBMERSIBLE PUMP
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>