KES XB6300-BK Black Shower Faucet Set Shower System with Tub Spout Installation Guide
- June 15, 2024
- KES
Table of Contents
KES XB6300-BK Black Shower Faucet Set Shower System with Tub Spout Installation Guide
WARNING
This shower system is NOT designed for outdoor use.
To reduce the risk of injury or property damage, read all instructions before
installing the product. Wear safety goggles. The product must be installed in
accordance with all state & local plumbing & building codes. Call a
professional if you are uncertain about installing this product.
ILLUSTRATED PARTS
WORKING CONDITIONS
Environment Temperature: S°C-49°C (41 °F-120°F)
In let Water Temperature: S°C-70°C ( 41 °F-l S8°F)
Water Pressure: 0.15M Pa-0.S0M Pa
Plumbing Connection: 1/2 ” -14NPT
Showerhead Connection Size: Gl/2 “
RECOMMENDED TOOLS
DIMENSION
VALVE BOX’S DISTANCE ADJUSTMENT
The maximum distance between the stringer and the front surface of finished
wall is 311/32″, and the minimum distance is 2 23/ 64″. The Recommended
Distance is 2 3/4″ for installation.
1. ROUGH-IN INSTALLATION
Notice: Turn off water supply before installation.
Step 1: For concrete wall, drill holes and place anchors into the holes.
Step 2: Attach valve box onto the wall or wood frame, secure it with screws.
Step 3: Connect valve with water supply (using plumber’s tape to avoid
leakage).
2. TRIM INSTALLATION
3. ADJUST TEMPERATURE LIMIT STOP
ADJUSTING THE ROTATIONAL LIMIT STOP:
IMPORTANT: The Rotational Limit Stop is used to restrict the amount of hot
water in the mix. By setting the Rotational Limit Stop properly, you can avoid
scald injury if the hand le is accidentally rotated all the way t o” hot “.
The First Position (shown in picture) allows the LEAST amount of hot water and
is the coldest position. As you move the Rotational Limit Stop
counterclockwise, you progressively add more and more hot water in the mix.
You will have the greatest amount of hot water in the mix and the greatest
risk of scald injury at The Last Position (shown in picture) counter
clockwise.
WARNING:
Setting the Rotational Limit Stop in The Last Position or beyond The Last
Position (counterclockwise) could result in scald injury. It is vital to
adjust the Rotational Limit Stop to avoid scald injury to the user when the
handle of the valve is rotated to the hot side. Please check your local
plumbing codes for maximum water mix temperature (norm ally should not exceed
120°F). If inlet water temperature changes seasonally, you may need to
readjust the Rotational Limit Stop. Recommend ed water temperature for bath or
shower is between 90°F-ll0° F.
Run the water so that the cold water is as cold as it will get and hot water is as hot as it will get. Place the handle on the cartridge stem and rotate the handle clockwise until the handle stops. Place a thermometer in a plastic tumbler and hold in the water stream. If the water temperature is above 120°F or the maximum temperature requirement of local plumbing codes (whichever is lower), the Rotational Limit Stop must be readjusted clockwise to decrease outlet water temperature.
WARNING:
MAKE SU RE COLD WATER FLOWS FROM THE VALVE FIRST.
MAKE SURE WATER FLOWING FROM THE VALVE AT THE HOTEST FLOW POSSIBLE DOES NOT
EXCEED 120°F OR THE MAXIMUM ALLOWED BY YOUR LOCAL PLUMBING CODES.
CAUTION:
This system/ device has to be set by the installer to ensure safe, maximum
temperature. Any variation in the setting may raise the discharge temperature
above the limit considered safe and may ca use hot water burns.
WARNING:
This pressure balance valve does not control temperature, only pressure
fluctuations. The Limit Stop does not control temperature variations ca used
by inlet temperature variations. Pressure balance valve will not provide
protection from hot water burns when there is a failure of other temperature
controlling devices elsewhere in the plumbing system.
And if the Rotational Limit Stop is not set properly, the hot water temperature is changed after the Rotational Limit Stop is set, or if the water inlet temperature changes due to seasonal variations, it also may will ca use hot water burns.
NOTICE TO THE INSTALLER:
CAUTION
As the installer of this valve, it is your duty to IN STALL and ADJU ST this
valve properly according to the instructions given. This valve does not adjust
automatically for inlet temperature changes, further adjustments maybe
necessary due to seasonal water temperature change.
YOU MUST inform the owner/ user of this requirement by following the instructions. After installation and adjustment, you must affix your name, company name and the date you adjusted the Rotational Limit Stop to a label and apply or attach the label to the backside of the closet cabinet door and a warning label to the hot water heater. Leave this instruction sheet for the owner’ s/user’s reference.
KES LIMITED THREE-YEAR WARRANTY
All parts of the KES product are warranted to the original consumer purchaser
to be free from defects in material and workmanship (“Defect”) for a period of
three (3) years. This warranty is made to
the original consumer purchaser and shall be effective from date of purchase
as shown on purchaser’s receipt.
During the warranty period, if defect is confirmed by KES’s inspection, KES
may, at its sole discretion, repair, provide a replacement of any part or the
whole product, or make appropriate adjustment where KES’s inspection discloses
any such defect. KES shall not be liable for any damage to the shower
system resulting from accident, misuse, abuse of use, outdoor use, extreme
weather, abnormally hot / freezing water in the plumbing, or aggressive air
and water conditions. Proof of purchase (original sales receipt) from the
original consumer purchaser must accompany all warranty claims.
KES will not be responsible for labor charges and/or damage incurred in
installation, repair or replacement, nor for any direct, indirect, incidental
or consequential damages, losses, injuries or costs ca used by the product. In
no event shall the liability of KES exceed the purchase price of the product.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY MADE BY KES. ANY CLAIMS MADE UN DER TH IS WARRANTY MUST BE MADE DURING THE TH REE YEARS PERIOD REFERRED TO ABOVE. ANY IMPLIED WARRANTIES, INCLUDING THE IMPLI ED WARRANTY OF MERCHANTABI LITY OR FITNESS FOR A PARTICU LAR PURPOSE, ARE LIMITED TO THE DURATION OF TH IS WARRANTY. KES AND/OR SELLER DISCLAIM ANY LI ABI LI TY FOR SPEC IAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES.
The above limitations or exclusions apply to you UNLESS the law of the places that you purchased KES product prohibit such limitations or exclusions.
This warranty does not extend to any damage to this product due to misuse, abuse, negligence, accident, improper installation, any use violating the instructions furnished by KES or any use of replacement parts other than genuine KES parts. If you ever use cleaners containing abrasive cleansers, ammonia, bleach, acids, waxes, alcohol, solvents or other products not recommended on KES product, any right you may have under t his warranty will be forfeited .
Keep Efficient Simple