MASTERVOLT 85000600 IVET 6 Isolation Transformer Instructions

June 5, 2024
MASTERVOLT

MASTERVOLT LOGO

MASTERVOLT 85000600 IVET 6 Isolation Transformer

INTRODUCTION

A safe connection between the vessel and shore installation is an essential part of your electrical system. A galvanic electrical isolation between shore power and the onboard power prevents any electrical corrosion of metal parts while keeping you earthed.

IVET Heavy-duty Series

High-output E-core isolation transformer without casing, for self- installation. The product is multi-tap, meaning you can handle 120/230/240 V going in and out. Mastervolt recommends installing the IVET heavy-duty isolation transformer with Soft Start. Soft Start suppresses the inrush current from the transformer and prevents the power fuse from blowing.

  •  High-quality isolation transformers without casing for self-installation.
  •  Optional Soft Start, in the synthetic casing.
  •  Capacities of 2.5 kW to 22 kW.

Specifications

General specifications

  • Output voltage (± 5 %) 120/220/240 V
  • Output frequency range 45-65 Hz
  • Input voltage range 110/220/240 V
  • Input frequency range 45-65 Hz
  • Nominal input current (230 V) 26 A
  • Galvanic isolation yes
  • Efficiency > 93 %
  • Power 6000 W
  • Dimensions, hxwxd 380 x 240 x 215 mm
  • 15.0 x 9.4 x 8.5 inch
  • Weight 49 kg
  • 108.0 lb
  • Compliance CE, ABYC

Technical specifications

  • Technology E-core
  • Earth leakage protection no
  • No-load power consumption < 10 W
  • Temperature range (ambient temp.) 0 °C to 40 °C, derating power > 40 °C 32 to 104 °F
  • Cooling natural cooling
  • Protection degree IP00
  • Operating humidity max. 95 %
  • Soft start option
  • MasterBus compatible no