SAFETY INSTRUCTIONS
Read the enclosed safety warnings, the additional safety warnings and the
instructions. Failure to follow the safety warnings and the instructions may
result in electric shock, fire and/or serious injury. Save the safety warnings
and the instructions for future reference.
The following symbols are used in the user manual or on the
product:
- Read the user manual.
- Denotes risk of personal injury, loss of life or damage to the tool in case of nonobser-vance of the instructions in this manual.
- Indicates electrical shock hazard.
- Protect the appliance against frost.
- Max depth.
- Do not dispose of the product in unsuitable containers.
- The product is in accordance with the applicable safety standards in the European directives.
SAFETY NOTES
THIS APPLIANCE CAN BE USED BY CHILDREN AGED FROM 8 YEARS AND ABOVE AND PERSONS
WITH REDUCED PHYSICAL, SENSORY OR MENTAL CAPA-BILITIES OR LACK OF EXPERIENCE
AND KNOWLEDGE IF THEY HAVE BEEN GIVEN SUPERVISION OR INSTRUCTION CONCERNING
USE OF THE APPLIANCE IN A SAFE WAY AND UNDERSTAND THE HAZARDS INVOLVED.
CHILDREN SHALL NOT PLAY WITH THE APPLIANCE. CLEANING AND USER MAIN- TENANCE
SHALL NOT BE MADE BY CHILDREN WITHOUT SUPERVISION. IF THE SUPPLY CORD IS
DAMAGED, IT MUST BE REPLACED BY THE MANUFACTURER, ITS SERVICE AGENT OR
SIMILARLY QUALIFIED PERSON IN ORDER TO AVOID A HAZARD. THE PLUG MUST BE
REMOVED FROM THE SOCKETOUTLET BEFORE CLEANING OR MAINTAINING THE APPLIANCE.
Please read these instructions carefully and thoroughly before using this
appliance and keep them for future reference. It is very important that you
understand how to use this appliance safely so please take the time to
familiarise yourself with the requirements as outlined in these instructions.
- If you are in any doubt what so ever about using this appliance, we strongly recommend that you employ the services of a suitably qualified person.
- Electrical connection must be protected by a re-sidual current device (RCD) at the power socket with a nominal trip current of 30mA (max).
- Keep children and pets well away from the work area and never allow children to use this appli-ance or touch the extension cord at any time. When not in use, keep this appliance stored in a safe place out of reach of children.
- Never leave the appliance unattended when in use.
- Never pull the appliance by its power cord. Carry it using the carry handle.
- Do not allow the power cord to lay on or across sharp objects that might pierce the outer insu-lation. Carry out a visual inspection of the power cord before use and if it is damaged, have it replaced by a specialist service centre. Do not use the appliance if the cord is damaged.
- Keep the power cord away from heat, frost, oil, solvents or any sharp objects or edges.
- Electrical connections e.g. extension cable, must be protected from moisture at all times.
- Check that the power rating on your appliance corresponds with the power rating at you mains supply. The supply voltage must be 230VAC.
- Never run this appliance dry – out of the water. If the appliance overheats, the thermal cut-out will switch it off. If this happens wait 5 minutes before using the appliance again.
- Always have the appliance switched off and the plug removed from the power socket before placing it in or removing it from the water. Only switch the power back on with dry hands.
- Never use this appliance in a pond or swimming pool while people are present in the water!
- Do not use the pump for drinking water.
- Corrosive, flammable or explosive substances, grease, oil, salt water and sewage must not be conveyed by the pump.
- The pH of water must between 6.5 and 8.5.
- The temperature of the liquid conveyed may not exceed 35 °C.
Electrical safety
When using electric machines always observe the safety regulations applicable
in your country to reduce the risk of fire, electric shock and personal injury.
Read the following safety instructions and also the enclosed safety
instructions.
Always check that the power supply corresponds to the voltage on the rating
plate.
Connecting to the power supply
Check that the power supply and plug used in accordance with your machine.
Have a look at the rating plate on the machine. Any changes should always be
carried out by a qualified electrician.
- Warning! This machine must be earthed. If not properly earthed this machine can cause an electrical shock. Be sure that the power supply outlet is earthed. If there is any doubt, have it checked by a qualified electrician.
- Warning! Avoid contact with the terminals on the plug when installing (removing) the plug to (from) the power supply outlet. Contact will cause a severe electrical shock.
Replacing cables or plugs
If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qual-ified persons in order to avoid a hazard.
Immediately throw away old cables or plugs when they have been replaced by new
ones. It is dangerous to insert the plug of a loose cable in the wall outlet.
Using extension cables
Only use an approved extension cable suitable for the power input of the
machine. The minimum conductor size is 1.5 mm². When using a cable reel always
unwind the reel completely.
MACHINE INFORMATION
The pump is intended for private use for draining flooded house and garden
areas but also for trans-ferring water to and from tanks and pumping them out,
from drawing water from wells and shafts and for draining boats and yachts.
Explosive, corrosive, flammable substances, sewage, salt water, grease and oil
must not be conveyed by the pump.
WWW.VONROC.COM
The particle sizes of the solids in the dirty water must not exceed the
maximum particle size speci-fied in the technical data.
This pump is not designed for continuous operation (e.g. as a swimming pool or
pond circulation pump) or for stationary installations (e.g. lifting device,
fountain pump).
TECHNICAL SPECIFICATIONS
Model No. | SP507AC |
---|---|
Application | Clean or dirty water |
Floating switch | Yes, built-in |
Voltage | 230 VAC / 50Hz |
Input power | 750W |
Max. flow rate | 14000l/h |
Max. pressure | 0.75 bar |
Max. pumping height | 7.5m |
Max.depth | 7m |
Max. particle size | 25mm |
Min. residual water height (manual operation) * | 50mm |
Switch-on height (automatic operation) | 23cm |
Switch-off height (automatic operation) | 6.5cm |
Max. water temperature | 35° C |
Protection | IPX8 |
Built-in thermal motor protector | Yes |
Output hose connection | 25mm, 32mm, G1” |
Recommended inner hose diameter | 32mm |
Water outlet | G1 1/2” |
Cable length | 10m |
Weight | 4.75 kg |
- The stated residual water height is only achieved in manual operation.
DESCRIPTION
The numbers in the text refer to the diagrams on page 2-3.
- Carry handle
- Operating mode switch (manual / automatic)
- Float cover
- Base
- Hose connector
- Water outlet elbow connector
- Water outlet
- Vent hole
- Sponge filter
- Bracket
- Float
- Float cover screws
ASSEMBLY
- The larger the hose and hose connector diameter, the greater the flow.
- 32mm (inner diameter) hose must be used to achieve maximum flow rate.
- The lower the delivery height, the greater the flow.
Attaching the outlet hose (Fig. A, B)
- Decide which hose diameter you are going to use. See figure B.
- Cut off the smaller steps of the hose connector (5) that are not needed, using a suitable knife or saw (not included).This removes unnecessary flow restrictions and ensures maximum pump capacity and water flow.
- Screw the outlet elbow connector (6) into the water outlet (7).
- Screw the hose connector (5) on the outlet elbow (6).
- Fit the hose on to the hose connector (5) and secure with a stainless steel hose clamp (not included).
- Attach a suitable rope (not included) to the carry handle (1), to lower the pump into deep water and to lift the pump back out of the wa-ter. Never lower or lift the pump by its cable.
OPERATION
Never use this pump in a pond or swimming pool while people are present in the water!
- Never pull the pump by its power cord. The pump must be carried by, and placed in the water using the carry handle (1) or if the water is deep, be lowered on a rope tied to the carry handle (1).
- Always have the pump switched off and the plug removed from the power socket before placing it in or removing it from the water. Only switch the power back on with dry hands.
- Never run this pump dry – out of the water. If the appliance overheats, the thermal cut-out will switch it off. If this happens wait 5 minutes before using the pump again.
- Automatic air bleed valve: The automatic air bleed valve eliminates any air pockets in the pump. During this process, air escapes through the vent hole (8) and air bubbles appear underwater. This is not a defect of your pump, but serves to remove air from the pump. It may take several seconds for the air to escape when the pump is immersed for the first time.
Automatic operation (Fig. A, C, D)
Clean the float (11), float cover (3) and filter (9) at regular intervals, and check it for damage. Otherwise, its function can be impaired.
- Slide the operating mode switch (2) to “AUTO”.
- Lower the pump into water. It would be advisa-ble to stand the pump on a solid platform at the bottom to keep it upright, if practical to do so. Ensure there are no obstructions around the in-let openings around the base of the pump. The inlet openings must be clear of mud or sludge at the bottom of a pool.
- Connect the mains plug.
- When the pump is lowered into the water and the power is switched on, it will start to operate as soon as the floating switch (11) reaches the minimum activation height (approx. 23cm) in the water.
- The pump switches off as soon as the float switch (11) has reached the switch-off height (approx. 6.5cm) due to the falling water level.
- Ensure that the float switch (11) is not obstruc-ted in any way. Clean the float (11), float cover (3) and filter (9) at regular intervals.
- After use, remove the mains plug from the mains.
- Lift the pump back out of the water.
Manual operation (Fig. A)
- Slide the operating mode switch (2) to “MANU-AL”.
- Lower the pump into water. It would be advisa-ble to stand the pump on a solid platform at the bottom to keep it upright, if practical to do so. Ensure there are no obstructions around the in-let openings around the base of the pump. The inlet openings must be clear of mud or sludge at the bottom of a pool.
- Connect the mains plug.
- On manual mode, the pump will always run. Never run this pump dry – out of the water.
- After use, remove the mains plug from the mains.
- Lift the pump back out of the water.
Finish operation
After use allow the pump to run using clean water for 2 – 3 minutes in order
to remove residues and particles that may have accumulated in the pump and
outlet hose.
MAINTENANCE
- Before cleaning and maintenance, always switch off the machine and remove the mains plug from the mains.
- During maintenance or cleaning never rest the appliance of the on the turbine (impeller).
Clean the machine casings regularly with a soft cloth, preferably after each
use. Remove very persistent dirt using a soft cloth moistened with soapsuds.
Do not use any solvents such as gasoli-ne, alcohol, ammonia, etc. Chemicals
such as these will damage the synthetic components.
If the appliance appears to be blocked, switch off the power at the mains,
remove the plug from the socket and check the appliance for blockages (see
‘Blockages’).
WWW.VONROC.COM
Clean the filter (A,C)
Clean the filter (9) at regular intervals, and check it for damage. Otherwise,
its function can be impaired.
- Carefully remove the bracket (10) and remove filter (9) as shown in Fig. C.
- Use a mild soap and water solution to clean the filter and afterwards rinse with clean water.
- Re-install the filter (9) and the bracket (10).
Clean the float and float cover (A,D)
Clean the float (11) and float cover (3) at regular intervals, and check it for
damage. Otherwise, its function can be impaired.
- Remove the float cover (3) by unscrewing the two screws (12).
- Use a mild soap and water solution to clean the float (11) and float cover (3) and afterwards rinse with clean water.
- Mount the float cover (3) by tightening the two screws (12).
Blockages
If you suspect the pump has become blocked, switch off the power at the mains
socket remove the plug and examine the turbine. The turbine can be accessed by
removing the securing screws in the base and/or sub base. Alternately try
reaching the suspected blockage through the outlet (7) in the side of the
pump.
Always flush through with clean water after every use.
STORAGE AND FROST PROTECTION
The submersible pump and accessories that are not completely drained can be
destroyed by frost. Completely drain the submersible pump and acces-sories and
protect them against frost.
Keep this appliance in well-ventilated dry premises with temperatures not
going below +5°C.
When not in use, keep this appliance stored in a safe place out of reach of
children.
TROUBLESHOOTING
Problem | Cause | Remedy |
---|---|---|
Pump does not start | No mains supply | Check mains supply |
Float stuck | Disconnect pump from the power sup- ply and clean float, float |
cover and filter (see ‘MAINTENANCE’)
| Switch-on height (automatic ope- ration)| The water is below the switch on
height of 23cm
| Not the right operating mode (manual mode)| Slide the operating mode switch
(2) to “MANUAL”
Pump is active| Turbine clogged| Disconnect pump
but no water is| | from the power
being delivered| | supply and clean or
| | unblock the turbine
| | (see ‘MAINTENANCE’)
Pump will not switch off| Not the right operating mode| Slide the operating
mode switch (2) to “AUTO”
| Float stuck| Disconnect pump from the power sup- ply and clean float, float
cover and filter (see ‘MAINTENANCE’)
| Switch-off height (automatic ope- ration)| The water is above the switch
off height of 6.5cm
Pump will not start or stops during use. Pump switched off after short operating periods| Thermal overload safety switch has activated
Power has tripped
Turbine clogged
Float stuck
Water too hot
| Disconnect from the power supply, leave for 2 minutes and clear the turbine (see ‘MAINTENANCE’)
Check fuses and elec- trical connections
Disconnect pump from the power supply and clean or unblock the turbine (see ‘MAINTENANCE’)
Disconnect pump from the power sup- ply and clean float, float cover and filter (see ‘MAINTENANCE’)
Ensure that the water temperature has not exceeded the maxi- mum of 35° C
---|---|---
ENVIRONMENT
Faulty and/or discarded electrical or electronic apparatus have to be collected at the appropriate recycling locations.
Only for EC countries
Do not dispose of power tools into domestic waste. According to the European
Guideline 2012/19/EU for Waste Electrical and Electronic Equipment and its
implementation into national right, power tools that are no longer usable must
be collected separately and disposed of in an environmentally friendly way.
WARRANTY
VONROC products are developed to the highest quality standards and are
guaranteed free of defects in both materials and workmanship for the period
lawfully stipulated starting from the date of original purchase. Should the
product develop any failure during this period due to defective material
and/or workmanship then contact VONROC directly.
The following circumstances are excluded from this guarantee:
- Repairs and or alterations have been made or attempted to the machine by unauthorized service centers;
- Normal wear and tear;
- The tool has been abused, misused or improp-erly maintained;
- Non-original spare parts have been used.
This constitutes the sole warranty made by compa-ny either expressed or
implied. There are no other warranties expressed or implied which extend
beyond the face hereof, herein, including the im-plied warranties of
merchantability and fitness for a particular purpose. In no event shall VONROC
be liable for any incidental or consequential damages. The dealers remedies
shall be limited to repair or replacement of nonconforming units or parts.
The product and the user manual are subject to change. Specifications can
be changed without further notice.
Documents / Resources
|
VONROC SP507AC Submersible Dirty Water
Pump
[pdf] Instruction Manual
SP507AC, Submersible Dirty Water Pump, SP507AC Submersible Dirty Water Pump,
Dirty Water Pump, Water Pump, Pump
---|---
|
VONROC SP507AC Submersible Dirty Water
Pump
[pdf] Instructions
SP507AC, SP507AC Submersible Dirty Water Pump, Submersible Dirty Water Pump,
Dirty Water Pump, Water Pump, Pump
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>