ETI SOLID STATE LIGHTING 54074491 LED Ceiling Lamp Instruction Manual

June 5, 2024
ETI SOLID STATE LIGHTING

ETI SOLID STATE LIGHTING 54074491 LED Ceiling Lamp

ETI SOLID STATE LIGHTING 54074491 LED Ceiling Lamp-
PROD

Product Introduction

Product Description

  1. Φ292x75mm;Dimension: Φ292x75mm
  2. Lamp plate: SPCC Powderspray, lamp cover: PMMA optical diffuser
  3. built‐in drive&fire prevention drive box
  4. 2835 Samsung ‐LED‐2835

Product schematic diagram:ETI SOLID STATE LIGHTING 54074491 LED Ceiling
Lamp-FIG1

Product Features

Product characteristics :

  • Long lifetime (above 50,000hrs), 7 times of the life of a fluorescent lamp:
  • High efficiency, energy saving, environmental friendly (A 14W led lamp can replace a 60 w electric incandescent lamp, saving 60% of energy )
  • Impact-resistant, shock resistant, no UV and IR radiation: high conversion rate and adaptable to severe environments, universal application to offices, hotels, supermarkets, schools, and libraries, etc
  • Green Initiative, no harmful gas is emitted, low heat is generated while used, safe and reliable .
  • Authentic and pure light color, no flicker, protecting your eyes while providing better visual enjoyment.

Specification

Item/ Parameter

Electronicratings
WRatedPower/W| 14.5W
VRatedInputvoltage/V| AC120V
HzFrequency/Hz| 60Hz|
---|---|---
%RatedPowerefficiency| 88%|
PF)RatedPowerFactor| 0.9|
ARatedInputcurrent/A| AC120V : 0.12|
RatedI‐THD| <20%|
R9RatedR9|  |
 |
Photometricratings|
LED LEDtype/Qty.| SMD2835 /20PCS|



LmRatedLumenOutput

| ****


1000lm

|
LuxIlluminance(1.5m)/Lux|  |
KCCT| 4000K|  |
RaCRI| ≥80|
BeamAngle| ≥110|
Physical information|
Material| SPCC+PMMA|
operating temperature| ‐20℃~45℃|
storage temperature| ‐20℃~60℃|
Prating| IP20|
(L×W×H)/mmLuminairedimension(L×W×H)/mm| Φ292×75|
get weight|  |
hrsLifetime/hrs| 50000h|

Light distribution

Installation Instructions

  1. Put the Fixture flat on the desktop, turn the lamp shade counterclockwise, and then take out the lamp shade.ETI SOLID STATE LIGHTING 54074491 LED Ceiling Lamp-FIG2
  2. Install the electrical box screws(#8-32UNC) in the junction box.
  3. Connect the black color L line(Mark 1) to the L line that comes out from the junction box with the wire cap. Connect the white color N line(Mark 2) to the N line that comes out from the junction box with the wire cap. Connect the green color ground line(Mark 3) to the ground line that comes out from the junction box with the wire cap.
  4. Put the central holes of the fixture plate across the screw of the junction box.ETI SOLID STATE LIGHTING 54074491 LED Ceiling Lamp-FIG6
  5. Rotate fixture plate per the direction of arrow and lock it tightly with the screw lockETI SOLID STATE LIGHTING 54074491 LED Ceiling Lamp-FIG7
  6. Lift the diffuser (B) with two hands. Aim the lock position of the diffuser (D) at one of the housing plates (C).Tightly get the diffuser (B) seated in the housing plate (A).Turn the diffuser (B) clockwise to secure it entirely with the housing plate.ETI SOLID STATE LIGHTING 54074491 LED Ceiling Lamp-FIG8

Maintenance instruction

  • Do Not use volatile solvents such as alcohol to clean the troffer.
  • Use a soft cotton cloth with suds to clean the troffer.
  • Non-professional Do not attempt to take apart and repair the troffer.
  • Please use the constant-current driver exclusively adaptive to the troffer, do not change the driver without permission.

FCC STATEMENT

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) this device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment. The device has been evaluated to meet general RF exposure requirements, the device can be used in portable exposure conditions without restriction.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

IC STATEMENT

This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:

  1. this device may not cause interference, and
  2. this device must accept any interference, including interference that may cause undesired operation of the device.

Environment requirement

  • Operating temperature:-20~45℃;
  • Storage temperature:-20~60℃。

Product carried standard

UL-1598/UL8750/ ENERGY STAR

Package Instruction

Packing Specification

Package list

|

Package size

| mm
---|---|---
 |

Lamp Qty./box

|

 |

Net weight

|
 |

Gross weight

|
|

Item

| Qty.
---|---|---
 |

Ceiling lamp

|

1

 | Instruction manual| 1
 | screw| 2
 | Wiring cap| 3

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals