Thank you for purchasing a Sealey product. Manufactured to a high standard,
this product will, if used according to these instructions, and properly
maintained, give you years of trouble-free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL
REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT IS CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS
INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY WILL
INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to instructions| Wear eye protection| Wear protective gloves| Wear a mask| Wear ear protection
SAFETY
WARNING! Ensure Health & Safety, local authority, and general workshop
practice regulations are adhered to when using this equipment.
WARNING! Disconnect from air supply before changing the blade or file,
servicing, or performing maintenance.
Maintain the tool in good condition (use an authorized service agent).
Replace or repair damaged parts. Use genuine parts only. Unauthorized parts
may be dangerous and will invalidate the warranty.
Use in a suitable clean and tidy work area, free from unrelated materials.
Ensure that there is adequate lighting.
WARNING! Always wear approved eye or face and hand protection when
operating the saw.
Remove ill-fitting clothing. Remove ties, and loose jewelry, and contain
and/or tie back long hair.
Wear appropriate protective clothing and keep hands and body clear of working
parts.
Maintain correct balance and footing. Ensure the floor is not slippery and
wear non-slip shoes.
Keep children and unauthorized persons away from the work area.
DO NOT use blades or files that are cracked or deformed.
Ensure that blades and files are clamped tightly to the air tool.
Check moving parts alignment on a regular basis.
Ensure the workpiece is secure before operating the saw. Never hold a
workpiece by hand. Use a vice or clamps.
WARNING! Ensure correct air pressure is maintained and not exceeded. The
recommended pressure is 90psi.
Keep the air hose away from heat, oil, and sharp edges. Check the air hose for
wear before each use and ensure that all connections are secure.
Prolonged exposure to vibration from this tool poses a health risk. It is the
employer’s/owner’s responsibility to correctly assess the
hazard and issue guidelines for safe periods of use and offer suitable
protective equipment.
DO NOT use any power source except an air compressor.
DO NOT operate the tool near any inflammable substance or on any container
that has held an inflammable substance.
DO NOT use a tool for a task it is not designed to perform.
DO NOT operate the tool if any parts are damaged or missing as this may cause
failure and/or personal injury.
DO NOT carry the tool by the hose or yank the hose from the air supply.
DO NOT operate tools when you are tired or under the influence of alcohol,
drugs, or intoxicating medication.
DO NOT carry the tool with your finger on the trigger.
DO NOT direct air from the air hose at yourself or others.
When not in use disconnect from the air supply and store in a safe, dry,
childproof location.
INTRODUCTION
Suitable for a variety of Bodyshop applications particularly where space is limited. Use as a cutting saw for panels or a file for deburring and shaping metalwork. Fitted with a safety trigger device. Supplied with a starter pack of blades and files.
SPECIFICATION
Model No.: ……………………………………………………. SA347.V2
Free Speed: …………………………………………………… 7500spm
Stroke: ……………………………………………………………… 5.5mm
Maximum Cutting Capacity: ……………1.2mm (Steel & Aluminium)
Air Consumption: ………………………………………………….. 4cfm
Operating Pressure: ……………………………………………… 90psi
Noise Power:…………………………………………………. 89.0dB(A)
Noise Pressure: ………………………………………………..78dB(A)
Vibration: ………………………………………………………… 12.2m/s²
Uncertainty: …………………………………………………….. 1.85m/s²
Air Inlet Size: …………………………………………………….1/4” BSP
Consumable Parts: SA347.NF5 – Replacement Needle File Set
PREPARATION
4.1. AIR SUPPLY
4.1.1. Recommended hook-up procedure is shown in fig.1.
4.1.2. Ensure Air saw trigger is in the “off” position before connecting to
the air supply.
4.1.3. You will require air pressure of 90psi, and airflow according to
specification.
WARNING! Ensure the air supply is clean and does not exceed 90psi while
operating the tool. Too high an air pressure and unclean air will shorten the
product life due to excessive wear and may be dangerous causing damage and/or
personal injury.
4.1.4. Drain the air tank daily. Water in the airline will damage the tool.
4.1.5. Clean air inlet filter weekly.
4.1.6. Line pressure should be increased to compensate for unusually long air
hoses (over 8 meters).
4.1.7. The minimum hose diameter should be 1/4” I.D. and fittings must have
the same inside dimensions.
4.1.8. Keep the hose away from heat, oil, and sharp edges. Check the hose for
wear, and make certain that all connections are secure.
4.2. COUPLINGS
4.2.1. Vibration may cause failure if a quick change coupling is connected
directly to the tool.
4.2.2. To overcome this, connect a leader hose to the tool. A quick change
coupling may then be used to connect the leader hose to the airline recoil
hose (fig.2).
OPERATION
WARNING! Ensure that you read, understand and apply the safety
instructions in Section 1.
WARNING! Disconnect from air supply before changing the blades or files.
5.1. USING THE SAW
5.1.1. Loosen the blade set screws, slide the saw blade into place and tighten
the blade screws.
5.1.2. Ensure that the workpiece is properly secured and, if necessary, marked
out.
5.1.3. Adjust the depth of cut by sliding the saw blade guide to the required
position and securing by tightening the blade guide screw.
5.1.4. Start the saw by pushing the safety catch forward, then pushing the
trigger down and bringing the moving blade onto the workpiece.
DO NOT attempt to start the saw with the stationary blade in contact with the
workpiece.
5.1.5. If the cut starts within the bounds of the material, cut a starter slot
by handsaw.
5.1.6. If the cut ends within the material, allow the blade to come to a stop
before removing the saw from the workpiece.
DO NOT allow the air tool to run free, whilst not being applied to the
material, for any length of time, as this will damage the bearings.
5.2. USING THE FILE
5.2.1. Select a file attachment appropriate for the job, loosen the blade
screws, slide the file into place and tighten the blade screws.
5.2.2. Ensure that the workpiece is properly secured and, if necessary, marked
out.
5.2.3. Start the saw by pushing the safety catch forward, then pushing the
trigger down, and bring the file to the work surface evenly and slowly.
DO NOT attempt to start the air tool with the stationary file in contact with
the workpiece.
5.2.4. Move the file back and forth in overlapping areas.
5.2.5. Remove the file from the work surface before stopping the air tool.
DO NOT allow the air tool to run free, whilst not being applied to the
material, for any length of time, as this will damage the bearings.
5.2.6. Regularly check the file attachments for wear, always change them if
cracked or damaged.
MAINTENANCE
WARNING! Disconnect saw from air supply before changing the blade or
file, servicing, or performing maintenance. Replace or repair damaged parts.
Use genuine parts only. Unauthorized parts may be dangerous and will
invalidate the warranty.
6.1. Unless the air supply system includes an oiler, lubricate the air saw
daily with a few drops of air tool oil dripped into the air inlet before use
(Sealey part no’s. ATO500S (500ml) or ATO1000S (1 Litre)).
6.2. Loss of power or erratic action may be due to the following:
a) Excessive drain on the airline. Moisture or restriction in the airline.
Incorrect size or type of hose connectors. To remedy this, check the
air supply and follow instructions in Section 4.
b) Grit or gum deposits in the saw may also reduce performance. If your model
has an air strainer (located in the area of the air inlet), remove the
strainer and clean it. Flush the aw out with gum solvent oil or an equal
mixture of SAE No 10 oil and kerosene. Allow drying before use. If you
continue to experience problems, contact your local Sealey service agent.
6.3. For full service, contact your local Sealey service agent.
6.4. When not in use, disconnect from the air supply, clean the saw, and store
it in a safe, dry, childproof location.
WARNING! – Risk of Hand Arm Vibration Injury.
This tool may cause Hand Arm Vibration Syndrome if its use is not managed
adequately.
This tool is subject to the vibration testing section of the Machinery
Directive 2006/42/EC. This tool is to be operated in accordance with these
instructions.
This tool has been tested in accordance with EN ISO 28927-2:2009 & BS EN ISO
15744:2008.
Declaration and verification of Vibration Emission figures are in accordance
with EN 12096:1997
Measured vibration emission value (a): 12.2 m/s²
Uncertainty value(k): 1.85 m/s²
Please note that the application of the tool to a sole specialist task may
produce a different average vibration emission. We recommend that a specific
evaluation of the vibration emission is conducted prior to commencing with a
specialist task.
A health and safety assessment by the user (or employer) will need to be
carried out to determine the suitable duration of use for each tool.
NB: Stated Vibration Emission values are type-test values and are
intended to be typical. Whilst in use, the actual value will vary considerably
and depend on many factors. Such factors include; the operator, the task, and
the inserted tool or consumable.
NB: ensure that the length of leader hoses is sufficient to allow
unrestricted use, as this also helps to reduce vibration.
The state of maintenance of the tool itself is also an important factor, a
poorly maintained tool will also increase the risk of Hand Arm Vibration
Syndrome.
Health surveillance.
We recommend a program of health surveillance to detect early symptoms of
vibration injury so that management procedures can be modified accordingly.
Personal protective equipment.
We are not aware of any personal protective equipment (PPE) that provides
protection against vibration injury that may result from the uncontrolled use
of this tool. We recommend a sufficient supply of clothing (including gloves)
to enable the operator to remain warm and dry and maintain good blood
circulation in fingers etc. Please note that the most effective protection is
prevention, please refer to the Correct Use and Maintenance section in these
instructions. Guidance relating to the management of hand-arm vibration can be
found on the HSC website www.hse.gov.uk – Hand-Arm
Vibration at Work.
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools,
accessories, and packaging should be sorted, taken to a recycling center, and
disposed of in a manner that is compatible with the environment. When the
product becomes completely unserviceable and requires disposal, drain any
fluids (if applicable) into approved containers and dispose of the product and
fluids according to local regulations.
Note: It is our policy to continually improve products and as such we
reserve the right to alter data, specifications, and component parts without
prior notice. Please note that the versions of this product are available. If
you require documentation for alternative versions, please email or call our
technical team at technical@sealey.co.uk or
01284 57505.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 24 months from purchase date, proof of which is
required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk.
IP32 7AR
01284 757500
01284 703534
sales@sealey.co.uk
www.sealey.co.uk
© Jack Sealey Limited
Original Language Version
© Jack Sealey Limited
Original Language Version
Documents / Resources
|
SEALEY SA347.V2 Reciprocating Mini Air Saw Needle
File
[pdf] Instructions
SA347.V2, Reciprocating Mini Air Saw Needle File, SA347.V2 Reciprocating Mini
Air Saw Needle File, Mini Air Saw Needle File, Air Saw Needle File, Saw Needle
File, Needle File, File
---|---
|
SEALEY SA347.V2 Reciprocating Mini Air Saw-Needle
File
[pdf] User Manual
SA347.V2 Reciprocating Mini Air Saw-Needle File, SA347.V2, Reciprocating Mini
Air Saw-Needle File, Mini Air Saw-Needle File, Air Saw-Needle File, Saw-Needle
File, File
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>