- inels RFSTI-11B-SL Switch Unit with Temperature Sensor
- Characteristics
- Assembly
- Connection
- Screwless terminals
- Radio frequency signal penetration through various construction materials
- Indication, manual control
- Programming with the RF control unit RF Touch (RFTC-50/G, eLAN-RF)
- Technical parameters
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
inels RFSTI-11B-SL Switch Unit with Temperature Sensor
Characteristics
- The temperature component measures the temperature with an external sensor and at the same time controls the heating circuit (electric underfloor heating, air conditioning, boiler…).
- They can be combined with Detectors, Controllers or iNELS RF Control system elements.
- It measures the temperature in the range of -20 to +50 °C and sends it to the system component at regular 5 min. intervals. When the temperature changes suddenly, it sends a signal.
- Setting the function of heating/cooling, hysteresis and off set is carried out in the system component or application.
- Allows connection of switched load up to 8 A (2,000 W).
- Range up to 200 m (in open air), in case of insufficient signal between the controller and the unit, use the RFRP-20N signal repeater or RFIO2 protocol devices that support this function.
- Communication with the bidirectional protocol RFIO2.
- The BOX version offers installation directly into the installation box, ceiling or cover of the controlled appliance. Easy to install thanks to screwless clamps.
- External sensor TC (-20 to +80 °C) or TZ (-40 to +125 °C) with a length of 3 m, 6 m, 12 m.
Assembly
Connection
Screwless terminals
Avoid rapid temperature changes, direct sunlight and excessive moisture. The temperature units should not be located near windows or heating equipment, etc., which could affect the internal temperature sensor.
Radio frequency signal penetration through various construction materials
1. | 2. | 3. | **4.** | 5. |
---|---|---|---|---|
60 – 90 % | 80 – 95 % | 20 – 60 % | 0 – 10 % | 80- 90 % |
brick walls | wooden structures with plaster boards | reinforced concrete | metal | |
partitions | common glass |
Indication, manual control
Pressing the button activates the output for 10 seconds. At this point, it is possible to check the wiring of the electrical circuit, without the need for assignment to the system.
Programming with the RF control unit RF Touch (RFTC-50/G, eLAN-RF)
- Description of function
- The external sensor measures temperature and sends the signal to RF Touch (RFTC-50/G, eLAN-RF).
- Programming
- An address listed on the front of the actuator is used for programming and controlling the temperature actuator RFSTI-11B-SL by RF Touch (RFTC-50/G, eLAN-RF).
Technical parameters
Supply voltage: | 230 V AC |
---|---|
Supply voltage frequency: | 50-60 Hz |
Apparent input: | 7 VA / cos φ = 0.1 |
Dissipated power: | 0.7 W |
Supply voltage tolerance: | +10 %; -15 % |
Temperature measurement input: | -20 až +50 oC |
Temp. measurement range and accuracy: | 0.5 oC of the range / z rozsahu |
Output
Number of contacts: | 1x switching / spínací |
---|---|
Rated current: | 8 A / AC1 |
Switching power: | 2000 VA / AC1 |
Peak current: | 10 A / <3 s |
Switching voltage: | 250 V AC1 |
Mechanical service life: | 1×107 |
Electrical service life (AC1): | 1×105 |
Control
Wireless: | 25 chanels |
---|---|
Communication protocol: | RFIO2 |
Frequency: | 866–922 MHz |
Function repeater: | yes |
Manual control: | button PROG (ON/OFF) |
Range: | up to200 m |
Other data
Operating temperature: | -15 až + 50 °C |
---|---|
Operating position: | any |
Mounting: | free at lead-in wires |
Protection: | IP40 |
Overvoltage category: | III. |
Contamination degree: | 2 |
Connection: | Screwless terminals |
Dimensions: | 43 x 44 x 22 mm |
Weight: | 31g |
Related standards: | EN 60730, EN 63044, EN 300 220, EN 301 489 |
Warning
Instruction manual is designated for mounting and also for user of the device.
It is always a part of its packing. Installation and connection can be carried
out only by a person with adequate professional qualification upon
understanding this instruction manual and functions of the device, and while
observing all valid regulations. Trouble-free function of the device also
depends on transportation, storing and handling. In case you notice any sign
of damage, deformation, malfunction or missing part, do not install this
device and return it to its seller. It is necessary to treat this product and
its parts as electronic waste after its lifetime is terminated. Before
starting installation, make sure that all wires, connected parts or terminals
are de-energized. While mounting and servicing observe safety regulations,
norms, directives and professional, and export regulations for working with
electrical devices. Do not touch parts of the device that are energized – life
threat. Due to transmissivity of RF signal, observe correct location of RF
components in a building where the installation is taking place. RF Control is
designated only for mounting in interiors. Devices are not designated for
installation into exteriors and humid spaces. The must not be installed into
metal switchboards and into plastic switchboards with metal door –
transmissivity of RF signal is then impossible. RF Control is not recommended
for pulleys etc. – radiofrequency signal can be shielded by an obstruction,
interfered, battery of the transceiver can get fl at etc. and thus disable
remote control.
ELKO EP declares that the RFSG type of equipment complies with Directives
2014/53/EU, 2011/65/EU, 2015/863/EU and 2014/35/EU. The full
EU Declaration of Conformity is at: https://www.elkoep.com/wireless-contact-
converter-230v—rfsg-1m
ELKO EP, s.r.o., Palackého 493, 769 01 Holešov, Všetuly, Czech Republic
Tel.: +420 573 514 211, e-mail: elko@elkoep.com,
www.elkoep.com
References
- Catalogs and brochures • ELKO EP
- ELKO EP - Hersteller von elektronischen Geräten • ELKO EP Germany
- ElkoEP - Fabricante de dispositivos electrónicos • ELKO EP ESPAÑA
- Input contact converter RFSG-1M • ELKO EP
- Katalogy • ELKO EP s.r.o
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>