Fanvil V64 Prime Business Phone Installation Guide
- June 4, 2024
- Fanvil
Table of Contents
- Packaging list
- Screen icon
- Keys features
- Installation the device
- Network connect
- Configuration
- Language setting
- Making a call
- Accepting a call
- Redial
- Call Mute
- Putting a call on hold
- Call transfer
- Call forward
- Call conference
- Programmable keys
- Do not disturb
- Voice mail
- Bluetooth
- WiFi
- Call list
- Phonebook
- Regulatory Compliance
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Fanvil V64 Prime Business Phone Installation Guide
Packaging list
IP Phone
Handset
Screen icon
Keys features
DSS Keys, It can be set as line key/function key/speed dial key, etc.
Soft keys
Message waiting indicator
Left and right navigation keys Up navigation key, Shortcut to call log Down navigation key, Shortcut to Status OK key, Shortcut to Menu
Home key, go back to Homepage
Return key, go back to the previous directory
Phonebook key
Voice message key
In idle mode or during ringing: increase or decrease ringer volume
In communication: increase or decrease handset, headset or hands-free volume
Headset key, activate/deactivateheadset
In idle mode: activate/deactivatesilentmode
In communication mode: mute/un-muteacall
Redial key, access to redial the last record Hand-free key, activate/deactivate hands free
Headset key, activate/deactivate head set In idle mode: activate/deactivate silent mode
Installation the device
Please follow the instructions in below picture to install the device.
Bracket desktop installation
Wall mounting (wall stand need buy separately)
Connecting to the device
Please connect power adapter, network, PC, handset, and headset to the corresponding ports as described in below picture.
- USB port: connect USB device (USB flash drive)
- Power port: connect the power adapter.
- Network port: connecting local area network or internet. ④ PC port: the network port connect to the computer.
- Headset port: connect headset.
- Handset port: connect IP Phone handset..
Network connect
Using Ethernet
- The power on the device and connect the WAN port of the phone to the RJ45 socket of a hub/switch or a router (LAN side of the router)using the Ethernet cable.
- The default is DHCP mode.
Using WiFi
- The power on the device and make sure the phone is idle.
- Press Menu > Basic > WLAN, Enabled the WiFi Feature.
- Press scan to search for currently available wireless network.
- Enter the available network and select the WiFi you want to connect.
- Press connect soft key and enter the appropriate password to connect to the WiFi. The default is DHCP mode.
Configuration
Configuration via LCD menu of phone
- Press Menu > Advanced (default password 123)
- Select Network: To configure the Network Settings(IPv4/IPv6/IPv4&IPv6, DHCP/Static/PPPoE).
- Select Accounts: To configure enable the account, fill the SIP server address, port, user name, password etc.
- Save the configuration.
Configuration via web
- Get the IP address from the phone: Press down navigation key, or Menu > Status > IPv4 / IPv6.
- Login: Input the IP address in the web browser. The PC and phone should be in the same IP address segment (The default user name and password are both ‘admin’.)
- Configure: Select network/account etc, and fill the relevant content. 4. Save the configuration.
Language setting
- Press Menu key > Basic > Language.
- Select the desired language and press OKsoft key.
Making a call
- Pre-dialing: enter the phone number and pick upt hehandset.
- Direct dialing: lift the handset and enter the phone number.
- Handsfree: enter phone number and press or vice versa.
- Headset: enter phone number and press or vice versa.
- Designated line: press line key, enter phone number and press dial key.
Accepting a call
- Using the handset: pick up the handset.
- Using the headset: press .
- U sing the handsfree: press .
Redial
- Press key, redial a call number
Call Mute
- Press to Mute the microphone during the call.
- Press again to un-mute the conversation.
Putting a call on hold
- Press Hold soft key, caller is put on hold.
- To retrieve the call press Resume soft key.
Note: with more than one active call, select desired call with the navigator key and use the corresponding soft key to hold or resume.
Call transfer
Attended transfer:
- Press Xfer soft key during the active conversation, the call is put on hold.
- Dial the second telephone number.
- When the call is answered, then press Xfer soft key to complete
the operation.
Blind transfer:
- Press Xfer soft key during the active conversation, the call will be on hold.
- Then enter the 2nd telephone number and press Xfer soft key.
Call forward
- Press Menu > Features > Call Forward.
- Select the line, the type of forward, enter the destination number and status, and press OK soft key.
Call conference
- Once in line with 1st caller, press Conf soft key, 1st caller is put on hold.
- Then call the 2nd number.
- After, 2nd call is established, press Conf soft key to set up the conference.
Programmable keys
- You can configure shortcuts for the programmable keys.
- Press Menu > Basic > Keyboard, select among the configurable items, and select your desired type and value, press OK key.
Do not disturb
- Press DND soft key, and enable the device do not disturb mode.
- Or press Menu > Features > DND, and select the Mode and Type, and press OK key
Voice mail
- To access your voice mailbox, press or Menu>Message>Voice Message, number of messages will be indicated if provided by your server or pbx.
- Select the line and press Play to call.
Bluetooth
- Press Menu > Basic > Bluetooth.
- Press OK soft key to enter the bluetooth open interface. After opening, press Scan soft key to display the list of bluetooth scanned. Select any device and press connect.
WiFi
- Press Menu > Basic > WLAN.
- Press OK soft key to enter the WLAN open interface. After opening, press Scan soft key to display the list of Wi-Fi scanned.
- Press Enter soft key to enter the available Network, select the wireless network, press the Connect soft key and enter the password to connect.
Call list
- Press up navigator key or Menu > Call Log >Local Call Logs
- Scroll through the list using navigator key.
- To dial an entry, press Dial soft key or pick up handset or press or .
Phonebook
Access Phonebook:
- Press or Contact soft key or Menu > Phone Book>Local Contacts.
- Select All Contacts or other group.
- To dial an entry, press Dial soft key or pick up handset or press or .
Add new entry:
- Press Contact soft key, Press All Contacts or other group>Press Add.
- Enter name and number and press OK soft key.
Regulatory Compliance
Federal Communication Commission (FCC) — USA
This device complies with Part 15 of FCC Rules. Operation is subject to the following two conditions:
- this device may not cause harmful interference, and
- this device must accept any interference received; including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installation.
This equipment generates, uses, and can radiate radio frequency energy, and if it is not installed and used in accordance with the instruction manual, it may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Warning: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with minimum distance of 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
This equipment complies with Part 68 of the FCC rules and the requirements adopted by the ACTA. On the bottom of this equipment is a label that contains, among other information, a product identifier in the format US: 3I1IPNANV64. If requested, this number must be provided to the telephone company.
Industry Canada Equipment Standard for Digital Equip-ment (ICES) — Canada
This Class B digital apparatus complies with Canadian ICES-003.
Innovation, Science and Economic Development (ISED) — Canada
This device contains licence-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science and Economic Development Canada’s licence-exempt
RSS(s).
Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with minimum distance of 20cm between the radiator and your body.
This device and it’s antennas(s) must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with IC multi-transmitter product procedures.
Fanvil Technology Co., Ltd
Website: www.fanvil.com
EMail: sales@fanvil.com
support@fanvil.com
Tel: +86-755-2640-2199 Fax: +86-755-2640-2618
Add: 10/F Block A, Dualshine Global Science Innovation Center, Honglang North 2nd Road, Bao’an District, Shenzhen, China
References
- Intermedia | Unified Communications, business email, cloud voice, web/video/content sharing, file backup, identity and access management, security & 30 cloud services
- Fanvil Technology Co., Ltd
- Intermedia Unite Common Topics & FAQs
- Technology & Services Industry Association | TSIA
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>