Fieldpiece CAT45 Combustion Analyzer Owner’s Manual

June 4, 2024
Fieldpiece

Fieldpiece LOGO Combustion Analyzer
Model CAT45
OPERATOR’S MANUALFieldpiece CAT45 Combustion
Analyzer

Safety Information

Only qualified personnel trained in the service and installation of electric heaters, boilers, and furnaces shall use this combustion analyzer
This device measures and analyzes key parameters of combustion equipment including oxygen, carbon monoxide, temperature, carbon dioxide, efficiency, and draft pressure
Read and understand this operator’s manual in its entirety before using it to prevent injury or damage to you or the equipment As with any job, appropriate use of personal protective equipment (PPE) is required

WARNING

  • Do not use the analyzer as a safety device.
  • Always be aware of and test for ambient CO levels.
  • Do not use unless in a well-ventilated location.
  • Do not use them in areas classified as hazardous locations; not intrinsically safe.
  • Do not use it unless a visual inspection ensures it’s safe to do so.
  • Ensure any connections to fuel sources are leak-free.
  • Do not touch or store the probe until it cools to ambient temperature.
  • Condensate may be acidic.
  • Combustion gases may be toxic even in low concentrations.
  • Seal any equipment holes used during testing in order to prevent dangerous flue gas from entering the space.

CAUTION

  • Do not use or store near solvents.
  • Do not clean with solvents.
  • Do not use it on a continuous basis.
  • Refer to 3rd party smoke test documentation to verify if smoke in equipment is at a safe level (1 or less). Not verifying this prior to conducting other tests, such as combustion, can result in damage to the analyzer and produce incorrect measurements.
  • This device should only be opened and/or serviced by authorized personnel. Gas sensors may be replaced by users.
  • Do not disconnect the combustion probe cable when powered on.
  • Use only within operating environment specifications.
  • Do not use it in rain or wet environments.

Description

The Fieldpiece CAT45 Combustion Analyzer provides a hassle-free solution for technicians to get the job done quickly, easily, and safely while improving system efficiency.
Accurate sensors of O2, CO, pressure, and temperature along with powerful trending provide key insight into equipment performance SensorVault™ technology seals to prolong sensor life

Features

  • 4 Year Gas Sensor Warranty
  • Large Intuitive Touchscreen
  • Powerful Trending
  • SensorVault™ Technology
  • Inline Water Trap
  • Rechargeable Battery
  • In-use USB-C Charging
  • Field Replaceable Smart Sensors
  • Job Link® System App Compatible
  • Wireless Printer (CATPR) Compatible
  • Durable Hard Lined Case

What’s Included

  • Combustion Analyzer + Probe
  • Hard-Lined Carrying Case
  • Extra Dust Filters and O-rings
  • USB-C Charging Cable
  • Operator’s Manual
  • 1 Year Device Warranty
  • 4-Year Sensor Warranty

CAT45 HardwareFieldpiece CAT45 Combustion Analyzer - FIG
1

Common Sampling Points
The many types of combustion equipment vary in their design and therefore their ideal sampling points However, there are commonalities that make for useful guidelines when analyzing performance
Heed equipment manufacturer instructions above anything mentioned in this manual.

  • Before inserting the probe in the flue, it’s good practice to test for excessive soot which may lead to carbon buildup within the analyzer or overexpose sensors.
  • Use the probe cone lock to hold the probe tightly in place at the sampling point.
  • The center of the flue is often a good place to locate the sensing point of the probe, but locating it at the highest point of CO is best.

Fieldpiece CAT45 Combustion Analyzer - FIG 3

Operation

The CAT45 workflow is streamlined to quickly get into your job, complete your testing, send your report, and get onto your next job

SensorVault™ Technology
The SensorVault™ technology of the power button unseals sensors when powering on and seals the sensors when powering off This requires a bit more force than most other buttons so be sure to press fully You’ll hear a “click”

Inline Water Trap
Condensate of the hot flue gas must be emptied as the water trap fills else airflow to the sensors eventually stops Rotate 1/4 turn to open and dispose of condensate

Battery Charging
Charge the batteries with the USB-C cable connected to any USB charging port/adapter rated at 5V/2A DC CAT45 can be operated while charging If you have difficulty charging or using when connected, try a shorter cable or a USB port/adapter with higher-rated amps

Powering ON
Read the “Safety Information” section.

  1. Ensure the inline water trap is sealed.

  2. Move probe to fresh ambient air for accurate sensor zeroing.
    • This step should be executed outside of the test room and away from any vehicle exhaust where traces of CO could be lingering.
    • Do not rely on the analyzer alone to check for unsafe CO levels.

  3. Fully press the power button down until you feel and hear the “click” of the SensorVault™ technology UNSEAL the sensors.
    Press deeper if it displays “SEALED”.

  4. Wait for the start countdown to complete.

  5. Start testing. See the “Job Menu” section.

Allow the timer to count down before turning ON/OFF again.

Powering OFF
Read the “Safety Information” section.

  1. Complete your testing and reporting.

  2. Empty inline water trap.

  3. Move probe to fresh ambient air to clear CAT45 of hot flue gas.

  4. Fully press the power button down until you feel and hear the “click” of the SensorVault™ technology seal the sensors.
    The unit powers off when SEALED and purging is complete.
    Press deeper if it displays “UNSEALED.”

  5. Store safely. See the “Storage” section below.

Storage
Read the “Safety Information” section.

  • Ensure the probe has cooled to ambient temperature before inserting it into the protective sleeve of the carrying case.
  • Insert the CAT45 body upside down into the padded pocket so the display is fully covered and the cable is free to move.
  • Do not stack objects on top of the case.
  • The warmup is extended if freezing temperatures are detected, but it’s best to store it at room temperature.

Job Menu

The JOB MENU is the heart of CAT45 Each job has its own list of saved tests After saving your tests, view them directly in the Job Link® mobile app or send your report to a model CATPR wireless thermal printer SAVE AND EXIT when you’re ready for your next job Jobs are automatically numbered sequentially Open the JOB ARCHIVE to view, continue, or delete jobs.

Combustion
By default, the COMBUSTION test starts automatically after the startup is complete. This test analyzes flue gas from various heating equipment. Use this test to set up, test, and document equipment performance.

Read the “Safety Information” section.

  1. Ensure startup is complete. See the “Powering On” section.

  2. Mount the CAT45 onto a secure, cool, magnetic surface near the sampling point.

  3. Twist the probe cone lock into the flue port at the sampling point and secure the probe. See the “Common Sampling Points” section.

  4. Select COMBUSTION from the JOB MENU.

  5. Select the fuel and equipment type.

  6. View live measurements.
    For best results, test for at least 5 minutes near the center of the flue, where you find the highest level of CO.

  7. SAVE ALL measurements displayed.

  8. Remove the probe and cone from the flue when finished.
    Be careful not to let the metal touch anything until it cools.

Reference Ranges
When selecting equipment, the reference range icon shows when available. Temperature, O2, CO, and CO air free all have reference ranges. These ranges show the generally accepted ranges for the chosen equipment type. The arrow is GREEN if within the reference range and YELLOW if not. These ranges are for reference only.

ZERO PROBE
ZERO PROBE sets the pressure sensor to 0 and resets the oxygen zero point. Always remove the probe from the flue before using ZERO PROBE. For the very best O2 measurements, start the pump and keep the probe in ambient air for 2 minutes before using ZERO PROBE.

CO Sensor Overexposure
Do not power off if you see this warning. It appears if the CO sensor detects a potentially damaging level of CO. Remove the probe from the flue so fresh ambient air can pump through the device.

Trending
Use trending to check how combustion parameters change over time. See the “Settings” section for TRENDING SETUP.

Ambient CO
CO is a very dangerous gas and it’s critical that living spaces are clear of carbon monoxide.
Read the “Safety Information” section.

  1. Ensure startup is complete. See the “Powering On” section.
  2. Select AMBIENT CO from the JOB MENU.
  3. View CO measurement while walking through the living space.
  4. SAVE the measurement displayed.
    “DELETE” temporarily deletes a single value so you can retest.
    “DELETE TEST” deletes the test.

Ambient CO Warning
Vacate the area immediately if you see the Ambient CO warning. It appears if the CO sensor detects a harmful level of CO. The CO warning level can be adjusted from the warning screen.

Drafts
CAT45 does not measure draft pressure with the COMBUSTION test, but a saved FLUE DRAFT measurement shows during COMBUSTION. Draft pressure measurement is important for safety and performance.

Read the “Safety Information” section.

  1. Ensure startup is complete. See the “Powering On” section.

  2. Select DRAFTS from the JOB MENU.

  3. Mount the CAT45 onto a secure, cool, magnetic surface near the sampling point.

  4. ZERO PROBE to zero the probe’s pressure sensor.
    Always remove the probe from the flue before using ZERO PROBE.

  5. Move probe to desired sampling point- DILUTED, FLUE, or OVERFIRE.

  6. View live measurement.

  7. SAVE the measurement displayed.
    “DELETE” temporarily deletes a single value so you can retest. “DELETE TEST” deletes the test.

  8. Remove the probe from the sampling point when finished.
    Be careful not to let the metal touch anything until it cools.

Primary Air
Primary air temperature is measured during startup and is used for the COMBUSTION test. This is the temperature of the air going into the combustion equipment. It’s sometimes useful to set it after startup if the ambient temperature changes. You can enter it manually or use the probe’s temperature sensor.
Read the “Safety Information” section.

  1. Ensure startup is complete. See the “Powering On” section.
  2. Select PRIMARY AIR from the JOB MENU.
  3. Move the probe to the entry point of air into the combustion equipment.
  4. View live measurement or use the keyboard onscreen to manually enter a value.
  5. SAVE the temperature.
    “DELETE” temporarily deletes a single value so you can retest.
    “DELETE TEST” deletes the test.

Smoke
The smoke test is used to document the soot levels within the flue.
This is good practice when “dirty” combustion is expected in order to extend the life of CAT45 and equipment. A third-party smoke tester is needed.
Read the “Safety Information” section.

  1. Ensure startup is complete. See the “Powering On” section.
  2. Select SMOKE from the JOB MENU.
  3. Use your smoke tester to find the smoke level.
  4. Select the corresponding level on the screen.
  5. SAVE the smoke level.
    “DELETE” deletes the entry.

Customer
Each job has a customer entry. JOB ARCHIVE uses this entry for searching. You can use this field for whatever you want. For example, it can be a serial number or a phone number. See the “Settings” section for report contents.

  1. Ensure startup is complete. See the “Powering On” section.
  2. Select CUSTOMER from the JOB MENU.
  3. Use the keyboard to enter.
  4. SAVE the customer.
    “DELETE” deletes the entry.

Note
Each job has a note entry.

  1. Ensure startup is complete. See the “Powering On” section.
  2. Select NOTE from the JOB MENU.
  3. Use the keyboard to enter.
  4. SAVE the note.
    “DELETE” deletes the entry.

Report
Each job has a report which is a collection of saved tests, your company info, reference O2, date, and time. The date and time are recorded at the time of sending the report. Edit report contents from settings.

  1. Ensure startup is complete. See the “Powering On” section.

  2. Select REPORT from the JOB MENU.
    At least one test must be saved to view the job report.
    Access the JOB MENU of saved jobs from JOB ARCHIVE.

  3. Scroll through the report using the scroll bar.

  4. PRINT to model CATPR wireless thermal printer.
    The PRINT button is active if CATPR is detected.

  5. DELETE JOB deletes the job from memory.

Job Link® System Reporting
Turn Job Link System ON to view CAT45 in the Job Link system mobile app (see “Settings” section). The Fieldpiece Job Link system app is extremely powerful and ever-evolving.
View live combustion and all saved tests of the current job directly in the app. Then email a report quickly and easily directly from your mobile device!

Save and Exit
SAVE AND EXIT to save your job and start a new job, sequentially numbered. You can return to saved jobs from JOB ARCHIVE.

Low Memory Notice
A notice appears when memory is too low to SAVE AND EXIT. Delete jobs individually from JOB ARCHIVE or delete all jobs from SETTINGS.

Job Archive
Open JOB ARCHIVE from the JOB MENU.

  • Sort jobs by date.
  • Search jobs by customer.
  • Select a job to open it.
  • Use the X icon to delete a job

Settings

Access SETTINGS from the top right corner of the Job Menu Each setting button cycles through its options or to its own screen (blue arrow)
The DEFAULTS button in the top right corner of the settings reverts to default settings, but jobs are not deleted

Job Link® System: OFF (default), ON
Select ON to view live combustion and saved tests on the Job Link system mobile app. (Which affects battery life.)
Brightness: HIGH, MEDIUM (default), LOW (Affects battery life.)
Button Sound: ON (default), OFF (Affects battery life.)
Sensor Remaining (status): % O2 and % CO sensor life remaining.
New sensors show 100%. When the life of either sensor is below 5%, a notice appears at startup.
Memory % Free (status): % of memory remaining for saving jobs.
When memory is too low, a notice appears when trying to SAVE AND EXIT a job. DELETE ALL is a quick way to delete all jobs and restart at JOB #1. Delete single jobs from within the JOB ARCHIVE screen.
Date and Time: EDIT to adjust the date and time. 24-hour time is always used. The date format is always set to Year-Month-Day for easy sorting.
Company Information: EDIT to adjust Company Information shown on reports.
Startup Screen: COMBUSTION (default), JOB MENU, FUEL TYPE Set which screen you want to see after the start countdown is complete.
Auto Hold Display: PUMP STOP (default), NEVER Select NEVER to continue viewing live measurements while the pump is stopped.
Combustion Setup: EDIT to select parameters and their slots on the COMBUSTION screen. To hide a slot completely, assign a parameter to the slot you want to hide, then assign that parameter to another slot.
Trending Setup: EDIT to select parameters on the TRENDING screen. SET LIMITS to adjust each parameter’s UPPER (maximum) and LOWER (minimum) values of the graph. Controlling these limits allows you to effectively zoom and shift each parameter independently for better visibility.
Report Contents: EDIT to select what is shown on reports.
Language (status): English (default) This is not adjustable.
Temperature Unit: ° F (default), °C
Pressure Unit: inWC (default), torr, Pa
[%] Reference O2: 6.0% (default) EDIT to adjust the reference oxygen % used for calculating CO Air Free.
Efficiency Calculation: Standard (default), Siegert. Siegert’s formula is typically only used in parts of Europe.
Firmware [version]: UPDATE to install new firmware if it becomes available at www.fieldpiece.com

Maintenance

General
Wipe with a damp cloth to clean the exterior Do not use solvents

Fieldpiece CAT45 Combustion Analyzer - FIG 7

Dust Filter Replacement
Replace the dust (particulate) filter if you notice slow response times or when it’s visually darker
Dust Filters: model RFC10

  1. Ensure the probe has cooled before opening to avoid contact with hot gas and liquid that may be within the probe.
  2. Rotate the Filter Cap 1/4 turn counter-clockwise to release.
  3. Pull out the old Probe Filter and replace it if needed.
  4. Pull out the O-ring and replace it if needed.
  5. Replace the Filter Cap.

Fieldpiece CAT45 Combustion Analyzer - FIG 8

Sensor Replacement
SensorVault™ technology prolongs the life of sensors, but they eventually need to be replaced When a sensor’s life drops below 5%, a notification appears during startup to inform you it’s time to replace it You can view the estimated remaining life at any time in SETTINGS
O2 sensor: model RSO2L
CO sensor: model RSCOR

  1. Double-check which sensor needs to be replaced.
    Leave a new sensor in its packaging until you’re ready to install it.

  2. Power off CAT45.

  3. Use a 2.5mm hex key to remove the two socket head screws on the sensor cover labeled SENSOR ACCESS.

  4. Lift up the bottom of the sensor cover to reveal the gas sensors.

  5. Pull the old sensor straight out.

  6. Check and remove the new sensor from its packaging.

  7. Align and push the new sensor straight in.
    The sensor cover won’t close if the sensor is inserted incorrectly.

  8. Tilt the sensor cover lip back into place and fasten the screws.

  9. Power on CAT45 to check sensor life in SETTINGS.
    Anything above 95% is normal.

Calibration
Replacement sensors have calibration data built-in and do not require calibration

Specifications

Display: Touchscreen TFT LCD (5.5 in diagonal)
Probe Size: 10.7 in (272 mm) length, 0.32 in (8.0 mm) diameter
Accuracy: Stated accuracies at 23°C ±5°C, <75% R.H.
Battery Type: 3.7 VDC (nominal), 6400mAh, non-replaceable
Battery Life: 7 hours typical (pump running 80% of the time)
Charge Time: < 7 hours typical @ 5V/2A DC power (USB power adapter not included)
Charging Port: USB-C (Usable when connected to power.)
Memory: 1000 jobs (approx.)
Warm-Up Time: 45 seconds (90 seconds near freezing)
Operating Environment: 14°F to 104°F (-10°C to 40°C); < 75% RH (non- condensing)
Storage Temperature: -4°F to 140°F (-20°C to 60°C); < 80% RH
Weight: 39.5 oz (1120 g) with the probe
US Patent: www.fieldpiece.com/patents
Wireless Range: 1000 feet (305 meters)
Fuel Types: Natural Gas, Propane (LPG), Oil #2 (Light), Oil #6 (Heavy), Biofuel, Coal, Coal Town Gas, Coking Oven Gas, KOKS, Custom (x3)
Warranty: 1 year (4 years sensors only)
Job Link® System Minimum: BLE 4.0 devices running iOS 7.1 or Android™ Kitkat 4.4
Latest compatibility at www.fieldpiece.com
Printer: Fieldpiece Wireless Thermal Printer (model CATPR)
Certifications:

FCC ID: 2ALHRCATX5
IC: Industry Canada
IC: 22518-CATX5|
Waste Electrical and
Electronic Equipment
---|---

Test Parameters
Stack Temperature

Range: 32 to 752°F; 0 to 400°C
Best resolution: 0.1°F; 0.1°C
Accuracy:
±2.5°F [32°F to 212°F], ±(3.6°F or 1.5%rdg) [213°F to 752°F]; ±1.4°C [0°C to 100°C], ±(2.0°C or 1.5%rdg) [101°C to 400°C] 02
Range: 0 to 21 vol.%
Best resolution: 0.1 vol.%
Accuracy: ±0.3 vol.%
C0
Range: 0 to 4000 ppm
Best resolution: 1 ppm
Accuracy: ±20 ppm [0 to 400 ppm], ±5%rdg [401 to 2000 ppm], ±10%rdg [2001 to 4000 ppm] Draft Pressure
Range: 0 to ±0.8 inWC
Best resolution: 0.01 in WC
Accuracy: ±0.02 inWC
CO Air Free (Calculated)
Range: 0 to 4000 ppm
Best resolution: 1 ppm
CO2 (Calculated)
Range: 0 to CO2max vol.%
Best resolution: 0.1 vol.%
Excess Air (Calculated)
Range: 0 to 999%
Best resolution: 0.1%
Efficiency (Calculated)
Range: 0 to 100%
Best resolution: 0.1%
QA (Calculated)
Range: 0 to 25%
Best resolution: 0.1%
Dew Point (Calculated)
Range: 32 to 212°F; 0 to 100°C
Best resolution: 0.1°F; 0.1°C
Primary Air Temp
Range: 32 to 212°F; 0 to 100°C
Best resolution: 0.1°F; 0.1°C
Accuracy: ±2.5°F [32°F to 212°F]; ±1.4°C [0°C to 100°C] Ambient CO
Range: 0 to 200 ppm
Best resolution: 1 ppm
Accuracy: ±20 ppm

Limited Warranty

This device is warranted against defects in material or workmanship for one year from date of purchase from an authorized Fieldpiece dealer
The O2 and CO sensors are warranted against defects in material or workmanship for four years from the date of purchase from an authorized Fieldpiece dealer
Fieldpiece will replace or repair the defective unit, at its option, subject to verification of the defect
This warranty does not apply to defects resulting from abuse, neglect, accident, unauthorized repair, alteration, or unreasonable use of the analyzer
Any implied warranties arising from the sale of a Fieldpiece product, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the above Fieldpiece shall not be liable for loss of use of the analyzer or other incidental or consequential damages, expenses, or economic loss, or for any claim of such damage, expenses, or economic loss
State laws vary The above limitations or exclusions may not apply to you

Obtaining Service
Visit www.fieldpiece.com/rma for the latest information on how to obtain service
Warranty for products purchased outside of the US should be handled through local distributors
Visit our website to find your local distributor