Fieldpiece JL3LC Job Link System Premium Large Pipe Clamp Probe User Manual
- June 5, 2024
- Fieldpiece
Table of Contents
- Fieldpiece JL3LC Job Link System Premium Large Pipe Clamp Probe
- Quick Start
- What’s Included
- Description
- Maintenance
- Specifications
- Operation
- Rapid Rail™ Sensor Advantages
- Limited Warranty
- Certifications and Module IDs
- FCC Statement
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Fieldpiece JL3LC Job Link System Premium Large Pipe Clamp Probe
Quick Start
- Install the Fieldpiece Job Link® system app on your mobile device and sign up for an account if you’re a new user.
- Remove the screws of the battery cover and install 2 x AAA batteries.
- Press for 1 second to power on.
- Open Measurements in the Job Link® app and favorite the probe to the tool manager.
- View live measurements on your mobile device
What’s Included
Job Link® System Premium Large Pipe Clamp Probe 2 x AAA Batteries
Emery Cloth for Cleaning Pipes
Operator’s Manual
1 Year Limited Warranty
WARNING The entire JL3LC may become hot when testing hot pipes or cylinders. Use caution when handling.
Description
The JL3LC Job Link® System Premium Large Pipe Clamp Probe sends long-range
wireless pipe temperature measurements directly to the Fieldpiece Job Link®
system mobile app. Take advantage of Rapid Rail™ sensor technology for
extremely fast and accurate measurements that surpass Title 24 requirements.
The Rapid Rail™ thermocouple is specifically designed to work on HVACR
electrically conductive piping and uses the pipe itself to complete the
circuit, resulting in high-temperature accuracy!
The perfect balance of size and capability allows for quick deployment on a
system. The grooved handle inspires confidence when gripping. Work on a wide
range of pipes from residential suction lines to large commercial systems.
Maintenance
CLEANING: Clean the exterior with a damp cloth. Do not use detergents or
solvents.
BATTERIES: When the LED slow blinks red, the batteries must be replaced.
Ensure the power is OFF. Remove the screws from the battery cover. Install 2 x
AAA batteries. You can also monitor battery life in the Job Link® app tool
manager.
CALIBRATION: The JL3LC is wireless so it doesn’t need to be calibrated as
often as wired thermocouples. To verify accuracy, submerge just the sensor
into ice water. Depending on atmospheric pressure and water purity, the
measurement will be 32°F ± 1°F. If calibration is required, use the tool
manager in the app to adjust the offset for that particular tool.
Specifications
- Minimum Device Requirement: BLE 4.0 devices running iOS® 7.0 or Android™ 5.0 (Latest compatibility at www.fieldpiece.com)
- Pipe Contact Surface Compatibility: Electrically conductive Pipe Size Compatibility: 3/4″ to 4 1/8″ (19.05mm to 104.775mm) OD Sensor Type: Rapid Rail™ thermocouple (nickel-chromium / nickel aluminum)
- Measurement Feedback: Beeper and LED
- Measurement Range: -50°F to 257°F (-46°C to 125°C) Plastic body and wire insulation are designed to withstand a maximum continuous temperature of 257°F (125°C). Stabilization Time: 3 seconds typical
- Accuracy: ±4°F (±2.2°C) thermocouple only ±1.0°F (±0.6°C) after field calibration *Meets California’s Title 24 requirements
- Battery Type: 2 x AAA, NEDA 24A, IEC LR03
- Battery Life: 150 hours typical alkaline. LED blinks red when battery replacement is needed.
- Auto Power Off: 2 hours (APO can be disabled)
- Wireless Range: 350 feet (107 meters) line of sight. Obstructions affect distance.
- Radio Frequency: 2.4 GHz
- Operating Environment: -4°F to 122°F (-20°C to 50°C) at <75% RH
- Storage Temperature: -4°F to 140°F (-20°C to 60°C), 0 to 80% RH (with batteries removed)
- Temperature Coefficient: 0.1 x (specified accuracy) per 1.8°F (-4°F to 64°F, 82°F to 122°F), per 1°C (-20°C to 18°C, 28°C to 50°C) Weight: 0.61 lbs (277 g) US Patent: www.fieldpiece.com/patents
Operation
POWER:
Press for 1 second to power ON/OFF.
LED Color Indications
Green slow blink: normal operation Yellow blink: open thermocouple circuit
Red slow blink: batteries need to be replaced
High or Low Side Switch
The Job Link® system app knows which side you have selected for each probe.
Select Suction line or Liquid line and place it on the system appropriately.
Rapid Rail™ Sensor Advantages
Traditional pipe clamps sit on top of the pipe surface. Some sensors touch the
pipe, some have material between the pipe and the sensor. They can be affected
by wind, heat, corrosion, insulation, paint, dirt, etc.
The Rapid Rail™ sensor uses the pipe itself to complete the thermocouple
circuit. The pipe is part of the sensor! If you get a measurement, you know
it’s correct.
Because the pipe is the thermocouple junction, all you need is enough contact
for conductivity. This means the clamp can sit on an angle or on a bend
without loss in performance.
There is a beeper and an LED to indicate whether or not the circuit is closed
and a temperature is being measured:
Double beep and yellow LED = Open Circuit Single beep and green LED = Closed
Circuit
If you don’t get a measurement, there’s something on the pipe that’s blocking
the electrical circuit (and accuracy). Sometimes you can slightly rotate the
clamp back and forth around the pipe to cut through contaminants. Sometimes
you need to sand the pipe a bit.
Remote Data Logging
Use the Job Link® system mobile app to program the JL3LC to log measurements
starting at a specific time of day for up to 7 days. Auto power off disables.
- Make sure JL3LC is powered OFF.
- Open the Job Link® system mobile app.
- Press for 5 seconds to enter data logging mode. The LED will shine solid green.
- Set up the probe’s data logging parameters within the app. The LED will blink green while the app is sending setup instructions. The LED will slow blink blue when waiting for programmed start time to occur.
- 5 Place the JL3LC on the system.
- When the programmed start time is reached, the LED will very slowly blink green to indicate data logging has begun.
- When the programmed span has finished, the LED blinks and powers OFF.
- Repeat steps 1-3 and use the app to extract your data log from the JL3LC.
Auto Power Off (APO)
If the clamp hasn’t been opened/closed or the button pressed, it will
automatically power off after 2 hours. To disable APO until powered off, while
power is on tap twice. The LED will briefly blink red. To enable APO, while
power is on tap twice. The LED will briefly shine red.
Limited Warranty
This probe is warranted against defects in material and workmanship for one
year from date of purchase from an authorized Fieldpiece dealer. Fieldpiece
will replace or repair the defective unit, at its option, subject to
verification of the defect.
This warranty does not apply to defects resulting from abuse, neglect,
accident, unauthorized repair, alteration, or unreasonable use of the
instrument.
Any implied warranties arising from the sale of a Fieldpiece product,
including but not limited to implied warranties of merchantability and fitness
for a particular purpose, are limited to the above. Fieldpiece shall not be
liable for loss of use of the instrument or other incidental or consequential
damages, expenses, or economic loss, or for any claim of such damage,
expenses, or economic loss.
State laws vary. The above limitations or exclusions may not apply to you.
Obtaining Service
For international customers, warranty for products purchased outside of the
U.S. should be handled through local distributors. Visit our website to find
your local distributor.
Certifications and Module IDs
- EN 300 328
- Regulatory Compliance Mark
- Waste Electrical and Electronic Equipment
- Restriction of Hazardous Substances Compliant
- IC: Industry Canada 22518-JL3LC
FCC Statement
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one of the following measures:
- Reorient or relocate the receiving antenna.
- increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: To assure continued compliance, any changes or modifications
not expressly approved by the party responsible for compliance could void the
user’s authority to operate this equipment. (Example – use only shielded
interface cables when connecting to computer or peripheral devices).
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
This device complies with Industry Canada licence-exempt RSS-247 standard.
Operation is subject to the following two conditions: (1) this device may not
cause interference, and (2) this device must accept any interference,
including interference that may cause undesired operation of the device.
IC Radiation Exposure Statement: This equipment complies with IC RSS-102
radiation exposure limit set forth for an uncontrolled environment. This
equipment should be installed and operated with minimum distance 20 cm between
the radiator and your body.
IC Caution: This device complies with Industry Canada licence-exempt RSS
standard(s).
Operation is subject to the following two conditions: (1) This device may not
cause interference, and (2) This device must accept any interference,
including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux
appareils radio exempts de licence. L’exploitation est autorisée aux deux
conditions suivantes:
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>