Fieldpiece SR47 Wireless Refrigerant Scale Owner’s Manual
- June 5, 2024
- Fieldpiece
Table of Contents
SR47 Wireless Refrigerant Scale
Owner’s Manual
Quick Start
- Install the 9V battery into the remote display and 6 x AA batteries into the platform.
- Press for 1 second to turn on the platform.
- Press for 1 second to turn on the display.
- Read weight directly on the display.
Description
High capacity and rugged, the SR47 Wireless Refrigerant Scale combines best- in-class wireless electronics an on the remote is empty. Remove the rear battery cover and replace it.
Buttons
| Press for 1 second to power the platform on/off.
---|---
| Press for 1 second to power the remote on/off. Tap for backlight.
| Press for 1 second to tare tank for charging and recovering refrigerant.
| Press for 1 second to zero.
No weight should be on the platform.
| Tap to change units. Press for 1 second to search for available platforms to
connect to.
Display Icons
| Auto power off enabled on the platform
Remote display battery life
Platform battery life and wireless signal strength
Gross weight
4-digit ID indicator
Pounds
Kilograms
Ounces
Grams
---|---
Specifications
Specifications good in ambient conditions of 73°F ±9°F (23°C ±5°C), <75%
relative humidity
Over range: “OL” is displayed
Maximum load: 252.00 lbs (114.00 kg)
Max tank base diameter: 13 inches (33 cm)
Auto power off: 30 minutes of inactivity (no change in weight or buttons
pressed), (APO can be disabled)
Backlight: Blue, turns off in 2 minutes if no buttons are pressed
Accuracy:
±0.03%rdg + 0.25 oz (10 g), 0 to 66 lbs (0 to 30 kg)
±0.05%rdg + 0.25 oz (10 g), 66 to 252 lbs (30 to 114 kg)
Resolution and units:
lb oz (0.25 oz), lb (0.1 lb), oz (0.3 oz),
kg g (10 g), kg (0.1 kg), g (10 g)
Temperature coefficient: 0.1 x (specified accuracy) per °F
Wireless range: 1000 feet (305 meters) line of sight.
Obstructions affect distance.
Radiofrequency: 2.4 GHz
Battery type:
Remote display: 9V, NEDA 1604, JIS 006P, IEC 6F22
Platform: 6 x AA, NEDA 15A, JIS UM3, IEC LR6
Battery life:
Remote display: 80 hours typical alkaline (backlight off)
Platform: 200 hours typical alkaline
Operating environment: 32°F to 122°F (0°C to 50°C) at <75% RH
Storage temperature: -4°F to 140°F (-20°C to 60°C), 0 to 80% RH (with the
battery removed)
Weight: Platform with battery 7 lbs (3190 g), Remote with battery 0.49
lbs (220 g)
Water resistant: IP54 (Platform), IP64 (Remote)
Functions
Weight Measurement
Your SR47 scale is designed to measure refrigerant tanks weighing up to 252
lbs.
Placing items over 252 lbs on the scale may damage the scale.
- Remove the scale from the padded case and place the platform on solid, level ground.
- Press for 1 second to turn on the platform.
- Press for 1 second to turn on the display.
- Press ZERO for 1 second to zero out the scale.
- Set your tank on the platform and press TARE for 1 second to view only the change in the refrigerant.
- View the change in weight in real-time when charging or recovering refrigerant.
Backlight
Tap to turn on the blue backlight on the LCD. This is useful when the sun
is going down on late day jobs or any dark situation. The backlight uses extra
battery power than standard use.
Auto Power Off (APO)
If the weight is unchanged for 30 minutes, the platform will automatically
power off.
To disable APO, while power is on tap twice on the platform. The LED will
briefly blink red and APO will not be shown on the display.
To enable APO, while power is on tap twice on the platform. The LED will
briefly shine red and APO will be shown on the display.
Syncing a Display to a Platform
The included remote display is set up to view the platform at the factory. You
shouldn’t ever need to re-sync them. You can sync two SR47 remote displays to
a single SR47 platform if desired.
-
Press and hold the UNITS button for 1 second.
-
The ID# of a detected platform will show.
(This ID# is printed on the platform.) -
Tap the UNITS button to cycle through any other platforms detected.
-
Press and hold the UNITS button for 1 second to select a platform.
Using the Job Link® system app and SMAN digital manifold as a display:
Link the SR47 to the app or manifold to use as a display.
Tech Tips
Respect the Environment
Always use hoses with ball valves or low-loss fittings to minimize harmful
refrigerant gases entering the atmosphere.
Account for Your Hose Weight
Connect the hoses to the system and tank before zeroing the scale. After
charge/recovery is finished and the system is stable, note the weight before
removing hoses.
Use your Appropriate G-Value
Acceleration due to gravity in m/s2 (G-Value) varies slightly depending on
your altitude and location. Here are a few cities’ examples:
Los Angeles (default) | 9.796 |
---|---|
New York City | 9.802 |
Paris | 9.809 |
Sydney | 9.797 |
Denver | 9.798 |
- Hold UNITS while powering on display.
- With the current G-Value showing, tap TARE and ▶♥◀to scroll up and down respectively.
- Tap UNITS to save and exit.
Limited Warranty
This scale is warranted against defects in material or workmanship for one
year from the date of purchase from an authorized Fieldpiece dealer.
Fieldpiece will replace or repair the defective unit, at its option, subject
to verification of the defect.
This warranty does not apply to defects resulting from abuse, neglect,
accident, unauthorized repair, alteration, or unreasonable use of the
instrument.
Any implied warranties arising from the sale of a Fieldpiece product,
including but not limited to implied warranties of merchantability and fitness
for a particular purpose, are limited to the above.
Fieldpiece shall not be liable for loss of use of the instrument or other
incidental or consequential damages, expenses, or economic loss, or for any
claim of such damage, expenses, or economic loss. State laws vary.
The above limitations or exclusions may not apply to you.
Obtaining Service
For international customers, warranty for products purchased outside of the
U.S. should be handled through local distributors. Visit our website to find
your local distributor.
Certifications and Module IDs
| EN 300 328
---|---
| Regulatory Compliance Mark
| RSR47D: 2ALHR010
SR47: 2ALHR011
| Waste Electrical and
Electronic Equipment
IC: Industry Canada| RSR47D: 22518-BT010
SR47: 22518-BT011
| Restriction of Hazardous
Substances Compliant
FCC&IC Statement
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation.
This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to
try to correct the interference by one of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: To assure continued compliance, any changes or modifications
not expressly approved by the party responsible for compliance could void the
user’s authority to operate this equipment. (Example – use only shielded
interface cables when connecting to computer or peripheral devices).
This device complies with Part 15 of the FCC Rules. Operation is subject to
two conditions: (1) this device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that
may cause undesired operation.
FCC Radiation Exposure Statement
This equipment complies with FCC RF radiation exposure limits set forth for
an uncontrolled environment. This equipment should be installed and operated
with a minimum distance of 0.5 centimeters between the radiator and your body.
This transmitter must not be co-located or operating in conjunction with any
other antenna or transmitter. The antennas used for this transmitter must be
installed to provide a separation distance of at least 0.5 cm from all persons
and must not be co-located or operating in conjunction with any other antenna
or transmitter.
This device complies with Industry Canada licence-exempt RSS- 247 standards.
Operation is subject to two conditions: (1) this device may not cause
interference, and (2) this device must accept any interference, including
interference that may cause undesired operation of the device.
IC Radiation Exposure Statement: This equipment complies with IC RSS-102
radiation exposure limit set forth for an uncontrolled environment. This
equipment should be installed and operated with a minimum distance of 0.5 cm
between the radiator and your body.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>