READ BEFORE USE

By using this product, you signify that you have read, understand, and accept the terms and conditions here.
Read the following documents before using.

  1. Safety Guidelines
  2. Quick Start Guide
  3. User Manual

It is recommended to watch all tutorial videos on the official Anykit website and read the safety guidelines before using.
Prepare for your first use by reviewing the quick start guide and refer to this user manual for more information.

Video Tutorials
Scan the QR code to watch the AN150P tutorial videos, which demonstrates how to use the AN150P safely.

https://qrs.ly/wwf4i3p

ONLINE MANUAL
Scan this QR code to get the manual in PDF, which can be enlarged and viewed on your mobile device.

ANYKIT AN150P 360 Degree Articulating Borescope - qr
code1https://qrs.ly/vof1uvj

OVERVIEW

Features

  • 5-inch HD IPS Screen
  • 360° Joystick Articulating Borescope
  • 210° Image Rotation
  • Adjustable LED lights
  • Detachable Screen Design

Applications

  • Inspect inside pipes to identify blockages, leaks, corrosion, and other issues.
  • Examination of automotive engine internals, exhaust tubing, brake systems, etc…
  • Inspection of internal components like engines, combustion chambers, ducts, etc…
  • Assessment of equipment interiors for wear, corrosion, cracks, and similar conditions.
  • Surveying concealed areas within buildings, such as internal walls and pipelines.
  • Examination of ship hull interiors, compartments, drainage systems, etc…

SAFETY INSTRUCTION

WARNING! Please read all safety warnings and instructions before using this product. Failure to follow these warnings may result in electric shock, fire or serious injury.

  • Keep the tool dry, clean, free from oil, water, gas or other materials that may cause corrosion.
  • Keep your work area clean and well lit.
  • This appliance is not intended for use by persons with limited physical, sensory or mental capabilities.
  • This appliance is not intended for medical use or personal inspection.
  • Keep bystanders, and children away while operating the tool.
  • Do not overreach, keep proper footing and balance at all times.

ABOUT ANYKIT

Anykit is a trendy and practical tool brand. We focus on simplicity and ease of use, providing people with convenience in their everyday lives.
Our products including otoscopes, endoscopes, and a variety of household tools to enable DIY enthusiasts to embrace creativity and convenience.

KNOW YOUR PRODUCT

ANYKIT AN150P 360 Degree Articulating Borescope - KNOW YOUR
PRODUCT

SPECIFICATIONS

Image Resolution 1920*1080
Video Resolution 1280*720
DOF 20-100mm
FOV 70°
Manual dimming Three adjustment levels
Power supply 3.7V
Use time About 4h
Battery capacity 3000mAh
Camera light source Adjustable LED
Waterproof grade IP67
Camera probe material Wear resistant metal hose
Camera probe length 5ft (1m)

High temperature
protection| High temperature intelligent protection
Articulation| 360 Degrees
Steering angle| ≤ 210°
Bending radius| 38mm
Storage| Standard 32GB-TF Card

Work environment

Operating
environment| Machine| -20℃~70℃
---|---|---
Input voltage| DC5V/1A
Humidity| 10~80%

PREPARATION & SETUP

Step 1 : Install the screen and handle, align them with the interface, and press firmly until you hear a click, indicating that they are connected.

Step 2 : Remove the plastic screen cover.

Step 3 : Turn the camera on/off by pressing and holding the “POWER” button for a few seconds.

Step 4: Low Battery Indicator: If the battery icon on the screen displays low battery, please ensure it is fully charged before use.

DISPLAY

ANYKIT AN150P 360 Degree Articulating Borescope -
DISPLAY

SETTINGS

Press the button “ ” twice to enter the settings page.
Press “   ” and “ ” to select the items you need.
Press “ OK ” to save your choice.

|
---|---
| Automatic shut-down
| Language settings
| Date Time
| Temperature Unit
| Format
| Default Settings
| Version

CHANGE THE TEMPERATURE UNITS

  1. Long Press the power button to power on, the monitor will light up and the blue power indicator will turn on.

  2. Press the key twice.

  3. Use the“ ”and “ ” to select whether to set Fahrenheit or Celsius, then press the“OK” to confirm the temperatureunit.

  4. Then the temperature on the screen will be displayed in the unit you have selected.

LED BRIGHTNESS ADJUSTMENT

Press the “   ” briefly to adjust the brightness of the camera light.
The brightness cycles through bright, medium, dim, and light off.

ANYKIT AN150P 360 Degree Articulating Borescope -
DISPLAY5

ADJUSTABLE LENS FIELD OF VIEW

The articulation wheel allows for a 210” rotation, adjusting the lens field of view.

ANYKIT AN150P 360 Degree Articulating Borescope -
DISPLAY6

Tips: To achieve the max articulation angle, the cable should not be coiled in a circle.

ANYKIT AN150P 360 Degree Articulating Borescope -
DISPLAY7

Notice:When using the borescope, it is important to emphasize that the coil should not be wound up as this can affect the steering function and cause the articulation angle to become smaller.

SWITCH BETWEEN PHOTO & VIDEO RECORDING

Press “ ” to switch to the photo taking or video recording mode, and press “ ”( located at the back of the product)to take a photo or start recording.

ANYKIT AN150P 360 Degree Articulating Borescope -
DISPLAY8

IMAGE PLAYBACK

Press “ ” to switch to playback mode, press “ ” to select photo or video, press “ ” to play back the video.

ANYKIT AN150P 360 Degree Articulating Borescope - Playback
Mode

TF CARD INSERTION AND REMOVAL GUIDE

The device is equipped with a TF memory card(inserted). Gently press to eject the card.

Insert TF card:

  • Power off the device first before inserting the TF card.
  • Make sure the direction and the front and back orientation is correct when inserting the TF card.
  • Do not use excessive force when inserting or removing the TF card to prevent damage to the card slot structure.

COPY PHOTO AND VIDEO FILES TO COMPUTER

ANYKIT AN150P 360 Degree Articulating Borescope - TF
card1

You can use a TF card reader to copy data directly or use a Type-c cable to connect to a computer for copying.

MAINTENANCE

Before cleaning your borescope, it’s important to power it off and disconnect it to ensure it’s completely safe. To maintain optimal image quality, delicately wipe the camera lens with a soft microfiber cloth and cotton swab before andafter each use to remove dust and smudges.
When cleaning the screen, use a microfiber cloth and a mixture of warm water and medical-grade alcohol to gently wipe off dust and fingerprints. Avoid using abrasive cleansers, chemicals, or solvents as they can damage the device’s exterior and interior components. Be careful not to let moisture infiltrate any device openings or ports during the cleaning process, and ensure the device is thoroughly dry before reconnecting to power or use.
When storing the device, power it down and keep it in a dry, cool, and well- ventilated area. If your device features a coiled probe, gently coil it without bending it too tightly. Avoid coiling it tighter than it was packaged originally and shield it from direct sunlight, extreme temperatures, and humid conditions. Keep it away from sharp objects and heavy items to prevent any damage.
By following these detailed cleaning and maintenance instructions, you can extend the lifespan of your industrial endoscope while maintaining top-notch performance and image quality.

TROUBLESHOOTING

Problems Solutions
No Camera Unplug and reinsert the monitor, ensure the monitor and

controller are well connected.
No Picture| Check probe and power. Restart the device.
Cannot Be Turned On| Insufficient power, charge it and try to turn it on.
Auto Shutdown| The probe will automatically shut down when it exceeds the protection temperature, you can try to turn it on again after it cools down.
TF Card Insertion Error| Insert compatible card. Format if needed.
Unable to Charge| Check cable and port. Try different

cable/adapter.

Blurry Picture| Clean lens/screen. Adjust focus if possible.
Blurry Screen Display| Adjust contrast and brightness for clearer visuals.
Connection Interruption| Secure cable connection. Swap if needed.
Difficulty Operating| Study manual or video guides.
Abnormal Screen Colors| Check cable. Contact support if issue persists.
Screen Flickering or Lines| Check power. Restart.
Device Heating Up| Ensure ventilation. Avoid high temps.
Difficulty Starting the Device| Check battery. Hold power button.
Image Inversion or Reversal| Adjust image settings in menu.
Slow Screen Response| Restart device. Manage memory usage.
Difficulties Bending the Probe| Coil probe gently. Stop if resistance.
*If you encounter any issues while using the product, don’t hesitate to reach out to us. We’ll provide feedback within 24 hours and work swiftly to resolve the matter.

WARRANTY

30-Day Guarantee| We will give you a full refund if you are not satisfied with the product.
---|---
One-Year Warranty| We offer a limited warranty that commences from the date of purchase of the product.

Visit anykit.com or scan the QR code for more details.

CUSTOMER SUPPORT

If you have any questions or concerns about your product, please contact our Customer Support Team

| 1-877-888-7979
Mon.-Fri. 8:00-5:00 PST(US)
---|---
| support@anykit.com
| www.anykit.com
| @anykit
| @anykit
| Facebook Messenger

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals