Von Duprin RU Retrofit Kit Datasheet

June 2, 2024
Allegion

`VON DUPRIN

Von Duprin RU Retrofit Kit`

Remote undogging and remote monitoring

Overview

In many institutional facilities, traffic is funneled through main perimeter openings equipped with access control. The remaining secondary perimeter openings utilize mechanical hardware, some of which are mechanically dogged (unlocked) and undogged (locked) to enable push/pull operation.  The manual management and monitoring of these openings is inefficient and prone to human error.

The Von Duprin® RU retrofit kit for exit devices is a cost-effective solution for these secondary openings that enable remote undogging for centralized lockdown and door status monitoring. It connects wirelessly to our access control Physical Access  Control Software (PACS) providers via an IP or RSI/RS-485 connection to the ENGAGE™ gateway. It is a modular battery-powered kit that can be added to existing 98/99 and 33A/35A series devices. The RM option is a sensor-only configuration for exit-only or fire rate doors that require monitoring. It provides visibility to request to exit (RX), latches bolt monitor (LX), and door position switch (DPS). 2 This complimentary solution enhances security by expanding the reach of the access control system to secondary openings that traditionally would go unaddressed because of the cost and complexity of running wires. Bringing these secondary openings online provides a more comprehensive perimeter security package.

_1 Assuming dog and undog sequence use rate is 2 cycles per day, exception notification rate is one occurrence every 2 days, and door use of at least 200 cycles per day (sensor and wireless activity indication)._
_2 RU using ENGAGE software or PAC solution via Wi-Fi is available for scheduled lock-up events only. This solution is not available for real-time lockdown._

Features and benefits

  • Access control managed via an IP or RSI/ RS-485 connection to the ENGAGE gateway through PACS providers
  • Modular kit compatible with 98/99 and 33A/35A series devices
  • Enables undogging for centralized lockdown (via real-time IP or RS-485) or scheduled lockup (via Wi-Fi or real-time IP or RS-485)
  • Cylinder and hex mechanical dogging is maintained but can be overridden electronically
  • Enables comprehensive view of door status via a request to exit (RX), latch bolt monitor (LX), and door position switch (DPS)
  • Sensor only configuration version (RM) available for exit only doors or fire-rated doors
  • Battery life up to 2 years with 4 standard AA batteries1
  • Electronics Certifications: UL294 indoor, FCC Part 15 – Commercial
CYBERSECURITY

Learn about Allegion’s commitment

Main components of RU kit:

allegion-von-duprin-ru-retrofit-kit-datasheet - Wireless
specifications

Available status signals

  • *       *         *           *             *               *                 *                   *                     *                       *                         *                           * Request-to-exit
                      * Door position
                      * Interior cover tamper4
                      * Magnetic tamper
                      * Battery status
                      * Dog/undog status5
                      * Communication status4

ENGAGE™ mobile applications
The ENGAGE mobile application delivers simple and convenient site device set- up.

_1 Maximum audit storage capacity of the lock. Can vary upon access control software audit storage capacity when linked with an ENGAGE Gateway RS-485 to ACP._
_2 For offline management only._
_3 Assuming dog and undog sequence use rate is 2 cycles per day, exception notification rate is one occurrence every 2 days, and door use of at least 200 cycles per day (sensor and wireless activity indication)._
_4 Consult your access control software provider for a specific scope of support._
_5 Software indicates dog/undog status based on a sequence of events._

Mechanical specifications

Dogging Options  –  Cylinder Dogging, Hex Dogging
ANSI standard   –  ANSI/BHMA A156.25-2013 (Indoor/Outdoor)
(Meets or exceeds)  –  ANSI/BHMA A156.2-2011, Series 4000, Grade 1

allegion-von-duprin-ru-retrofit-kit-datasheet - Compatible device
lengths

Compatible device lengths

For Remote Undogging (RU) Module installation: All 33A/35A and 98/99 device types – 3′ (914 mm) length to 2′ 9″ (838 mm), 4′ (1219 mm) length to 3′ 3″ (991 mm)

For Remote Monitoring (RM) Module only: All 33A/35A and 98/99 device types – 3′ (914 mm) length to 2′ 83⁄4″ (832 mm), 4′ (1219 mm) length to 3’23⁄4″ (984 mm)

For Remote Monitoring (RM) Module with EL/QEL: All 33A/35A and 98/99 device types – 3′  (914 mm) length only, 4′ (1219 mm) length to 3′ 51⁄8″ (1045 mm)

How to order

Remote Undogging

RU 3′ kit   –   47258681

RU 4′ kit  –    47258682

Remote Monitoring

RM 3′ kit   –  47258683

RM 4′ kit   –  47258684

If the door and exit device are fire-rated, and the exit device type is a 98/99-F Rim manufactured prior to April 1, 2018, a new center case will be required before proceeding with the installation of the RM kit.  98/99-F Rim Center Case Kit Less Cover, part number 050026.

allegion-von-duprin-ru-retrofit-kit-datasheet 1

About Allegion

Allegion (NYSE: ALLE) is a global pioneer in safety and security, with leading brands like CISA®, Interflex®, LCN®, Schlage®, SimonsVoss®, and Von Duprin®. Focusing on security around the door and adjacent areas, Allegion produces a range of solutions for homes, businesses, schools, and other institutions. Allegion is a $2 billion company, with products sold in almost 130 countries. For more, visit www.allegion.com.

© 2020 Allegion
011898, Rev. 09/20
www.allegion.com/uss

Von Duprin RU Retrofit Kit Datasheet – Optimized PDF
Von Duprin RU Retrofit Kit Datasheet – Original PDF

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals