NUMRIC Digital 1000 Plus V UPS User Manual

June 1, 2024
NUMRIC

Digital 1000 Plus V UPS
User ManualNUMRIC Digital 1000 Plus V UPS Digital 1000 Plus V

Digital 1000 Plus V UPS

CONGRATULATIONS!
We are delighted to welcome you to our family of customers. Thank you for choosing Numeric as your reliable power solution partner, you now have access to our widest network of 250+ service centers in the country.
Since 1984, Numeric has been enabling its clients to optimize their business with top-notch power solutions that promise seamless and clean power with controlled environmental footprints. We look forward to your continued patronage  in the years to come. This manual contains detailed instructions on how to use, install and operate this product.

Disclaimer

  • The contents of this manual are bound to change without prior notice.
  • We have exercised reasonable care to give you an error-free manual. Numeric disclaims liability for any inaccuracies or omissions that may have occurred. If you find information in this manual that is incorrect, misleading or  incomplete, we would appreciate your comments and suggestions.
  • Before you begin the installation of the product, please read this manual thoroughly. The warranty of this product is null and void, if the product is abused/misused.

INTRODUCTION

Digital 1000 Plus V is designed for personal computers. Equipping double boost and single buck AVR, Digital 1000 Plus V UPS can stabilize a wide voltage range from 140 to 300 VAC. The fast charger ensures timely recharge of battery so that it is always ready for power backup. Built-in DC start function and generator compatibility makes UPS adapt to various operational conditions. The following points shows other handy features of Digital 1000 Plus V UPS.

  • Microprocessor control guarantees high reliability
  • Double boost & single buck AVR stabilize wide voltage fluctuations
  • Fast charger ensures battery readiness for power backup
  • DC start function
  • Generator compatibility
  • Auto restart while AC recovery
  • Compact size, light weight

IMPORTANT SAFETY INSTRUCTIONS

Save these instructions: This manual contains important instructions for the model Digital 1000 Plus V that should be followed during installation and maintenance of the UPS and batteries.

  • This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user serviceable parts. Only factory service personnel may perform repairs
  • Connection to any other type of receptacle other than a 2-pole, 3-wire grounding receptacle may result in shock hazard as well as violate local electrical codes
  • In the event of an emergency, turn the power switch to the ‘off’ position and disconnect the power cord from the AC power supply to properly disable the UPS
  • Do not allow any liquids or any foreign object to enter the UPS. Do not place beverages or any other liquid-containing vessels on or near the unit
  • This unit is intended for installation n a controlled environment (temperature controlled, indoor area free of conductive contaminants). Avoid installing the UPS in locations where there is standing or running water, or excessive humidity •
  • Do not plug the UPS nut into ts own output
  • Do not attach a power strip or surge suppressor to the UPS
  • Do not attach non-computer related items, such as medical equipment, life-support equipment, microwave ovens, or vacuum cleaners to UPS
  • To reduce the risk of overheating the UPS, do not cover the UPS” cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space heaters or furnaces Unplug the UPS prior to cleaning and do not use liquid or spray detergent
  • Do not dispose off battery or throw batteries n a fire. The battery may explode
  • Do not open or mutilate the battery or batteries. Released electrolyte is harmful to the skin and eyes. t may be toxic
  • A battery can presents risk of electrical shock and high short circuit current. The following precautions should be observed when working on batteries:
  1. Remove watches, rings, or other metal objects from the hand
  2. Use tools with insulated handles
    3] Wear rubber gloves and boots
  3. Do not lay tools or metal parts on the top of batteries
    5] Disconnect charging source prior to connecting or disconnecting batteries terminal
  • Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries
  • When replacing batteries, replace with the same type and number of the sealed lead-acid batteries. The maximum ambient temperature rating is 40°C
  • This pluggable type-A equipment with battery already installed by the supplier is operator installable and may be operated by laymen
  • During the installation of this equipment it should be assured that the sum of the leakage currents of the UPS and the connected loads does not exceed 3.5 mA
  • Beware of hazards that may arise through electric shocks. Also, while disconnecting this unit from the mains, may be available through. supply from battery. The battery supply should be therefore disconnected in the plus and minus pole of the battery when maintenance or service work inside the UPS is necessary
  • The mains socket outlet that supplies to the UPS shall be installed near the UPS and shall be easily accessible

SYSTEM DESCRIPTION

NUMRIC Digital 1000 Plus V UPS - Front panel

1. Power switch
2. AC Mode: green light
3. Battery Mode: yellow flashing
4. Fault: red light| 1 Output receptacles
2 AC input
3 Circuit breaker
---|---

INSTALLATION AND OPERATION

  1. Inspection
    Remove the UPS from its packaging and inspect it for damage that may have occurred during shipping.
    If any damage is discovered, repack the unit and return it to the dealer from whom you had purchased.

  2. Placement
    Install the UPS unit in any protected environment that provides adequate airflow around the unit, and is free from excessive dust, corrosive fumes and conductive contaminants. Do not operate your UPS in an environment where the ambient temperature or humidity is high.
    On the other hand, place the UPS at least 20 cms away from the monitor to avoid interference.NUMRIC Digital 1000 Plus V UPS -
Placement

  3. Charging
    This unit is shipped from the factory with its internal battery fully charged, however, some charge may be lost during shipping and the battery should be recharged prior to use. Plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged in for at least 8 hours with no load (no electrical devices such as computers, monitors, etc.) connected. NUMRIC Digital 1000 Plus V UPS - Charging

  4. Connection
    Plug the UPS into a 2-pole, 3-wire grounded receptacle. Then connect one computer related device into each of the power receptacles supplied on the back panel.
    Note: Circuit breaker rating of the branch circuit supplied from the mains input panel sizing must be 10 A/250 VAC in accordance with National Electrical Codes and Standards as per schematic (based on N.E.C NFPA 70 -2014; Reference: Article 240]NUMRIC Digital 1000 Plus V UPS -
Connection

  5. Turn On/Off
    To turn on the UPS unit, press the power switch lightly.
    To turn off the UPS unit, press the power switch again.

  6. DC Start
    This series is equipped with DC Start. To start the UPS when AC utility power is not available, simply press the power switch.

SPECIFICATIONS

Model Description Digital 1000 Plus V
Capacity VA/W 1000 VA/600 W
Input Voltage Range 140-300 VAC
Frequency 45-65Hz (Auto sensing)
Output Voltage 230 VAC (190-253 VAC)
Voltage regulation (Batt. mode) 230 VAC +/- 10%
Frequency regulation (Batt. mode) 50 +/-1 Hz
Waveform Quasi sine wave
Battery Battery type and number 12 V/7 Ah x 2 pcs
Back up time (1 PC load) 30 mins
Recharge time 4-8 hours to 90% after complete discharge
Transfer time Typical 4-8 ms, max 10 ms

Indicator

| AC mode| Green light
Back up mode| Yellow flashing
Fault| Red light
Audible alarm| Back up mode| Sounds every 10 seconds
Low battery| Sounds every second
Overload| Sounds every 0.5 seconds
Fault| Continuous sound
Protection| Full protection| Discharge/Over charge/Overload protection
Physical| Dimension (DXWXH)| 350 x 146 x 160 mm
Net weight| 8 kg
Environment| Operating environment| 0-40ºC, 0-90% relative humidity (non- condensing)
Noise level| Less than 40 dB

*Product specifications are subject to change without further notice

TROUBLE SHOOTING

Use the following table to solve minor problems. If any abnormal situation occurs that are not listed herein, please call service technician for assistance.

Problem Possible Cause Remedy
No LED display on the front panel Low battery Charge the UPS for at least 6

hours
Battery fault| Replace the battery with the same type of battery
The UPS is not turned on| Press the power switch again to turn on the UPS
Alarm beeps continuously sounds when the mains is normal| Overload of the UPS| Remove some loads first. Before reconnecting equipment, please verify that the load matches the UPS capability specified in the specs
When power fails, back-up time is shortened| Overload of the UPS| Remove some critical load
Battery voltage is too low| Charge the UPS for at least 6 hours
Battery defect. It might be due to high temperature operation environment, or improper operation to battery| Replace the battery with the same type of battery
The mains is normal, but the unit is on battery mode| Power cord is loose| Reconnect the power cord properly
Head Office
10th Floor, Prestige Center Court,
Office Block, Vijaya Forum Mall, 183,
N.S.K Salai, Vadapalani,
Chennai – 600 026.
Phone: +91 44 4656 5555
Regional Offices
New Delhi
B-225, Okhla Industrial Area,
4th Floor, Phase-1,
New Delhi – 110 020.
Phone: +91 11 2699 0028
Kolkata
Bhakta Tower, Plot No. KB22,
2nd & 3rd Floor, Salt Lake City,
Sector – III, Kolkata – 700 098.
Phone : +91 33 4021 3535 / 3536
Mumbai
C/203, Corporate Avenue, Atul Projects,
Near Mirador Hotel, Chakola,
Andheri Ghatkopar Link Road,
Andheri (East), Mumbai – 400 099.
Phone : +91 22 3385 6201
Chennai
10th Floor, Prestige Center Court,
Office Block, Vijaya Forum Mall,
183, N.S.K Salai, Vadapalani,
Chennai – 600 026.
Phone : +91 44 3024 7236 / 200
Branch Offices
Chandigarh
SCO 4, First Floor, Sector 16,
Panchkula, Chandigarh – 134 109.
Phone : +91 93160 06215
Dehradun
Unit-1 and 2, Chakrata Road,
Vijay Park Dehradun – 248001.
Uttrakhand
Phone : +91 135 661 6111
Jaipur
Plot No. J-6, Scheme-12B,
Sharma Colony, Bais Godown,
Jaipur – 302 019.
Phone : +91 141 221 9082| Lucknow
209/B, 2nd Floor, Cyber Heights,
Vibhuti Khand, Gomti Nagar,
Lucknow – 226 018.
Phone : +91 93352 01364
Bhubaneswar
N-2/72 Ground Floor, IRC Village,
Nayapally, Bhubaneswar – 751 015.
Phone: +91 674 255 0760
Guwahati
House No 02,
Rajgarh Girls High School Road
(Behind Rajgarh Girls High School),
Guwahati – 781 007.
Phone : +91 96000 87171
Patna
405, Fraser Road, Hemplaza,
4th Floor, Patna – 800 001.
Phone : +91 612 220 0657
Ranchi
202 & 203, 2nd Floor, Sunrise Forum,
Bardwan Compound, Lalpur, 2nd Floor,
Ranchi – 834 001.
Phone : + 91 98300 62078
Ahmedabad
A-101/102, Mondeal Heights,
Beside Hotel Novotel, Near Iscon Circle,
S G Highway, Ahmedabad – 380 015.
Phone : +91 79 6134 0555
Bhopal
Plot No. 2, 221, 2nd Floor, Akansha Complex,
Zone-1, M.P.Nagar, Bhopal– 462 011.
Phone : +91 755 276 4202
Nagpur
Plot.No.174, H.No.4181/C/174, 1st Floor,
Loksewa Housing Society, Near Dr. Uma the
& Mokhare College, Bhamti Road,
Lokseva Nagar, Nagpur – 440 022.
Phone : +91 712 228 6991 / 228 9668| Pune
Pinacle 664 park avenue, 8th floor,
Plot no 102+103, CTS No. 66/4,
Final, 4, Law College Rd, Erandwane,
Pune, Maharashtra – 411 004.
Phone : +91 +20 6729 5624
Bengaluru
No-58, First Floor, Firoze White Manor,
Bowring Hospital Road,
Shivajinagar, Bangalore -560 001.
Phone : +91 80 6822 0000
Coimbatore
No. B-15, Thirumalai Towers, No. 723,
1st Floor, Avinashi Road, Coimbatore – 641 018.
Phone : +91 422 420 4018
Hyderabad
Prestige Phoenix Building,
1st Floor, Survey no. 199,
No. 6-3-1219/J/101 & 102, Uma Nagar,
Opposite to Begumpet Metro Station
Begumpet 500016
Phone: +91 40 4567 1717/2341 4398/2341 4367
Kochi
Door No. 50/1107A9, JB Manjooran Estate,
3rd Floor, Bypass Junction,
Edappally, Kochi – 682 024.
Phone : +91 484 6604 710
Madurai
12/2, DSP Nagar,
Dinamalar Avenue,
Madurai – 625 016.
Phone : +91 452 260 4555
---|---|---

Contact us.:
Email : [email protected]
Phone : 0484-3103266 / 4723266
www.numericups.com