NUMRIC Digital 600 EX UPS User Manual

June 1, 2024
NUMRIC

NUMRIC Digital 600 EX UPS

NUMRIC-Digital-600-EX-UPS-PRODCUT

Specifications

  • Model: Digital 600 EX
  • Designed for: Personal computers
  • Voltage Range: 140 to 300VAC
  • Features: Double boost and single buck AVR, fast charger recharge battery, built-in DC start function, generator compatibility

CONGRATULATIONS
We are delighted to welcome you to our family of customers. Thank you for choosing Numeric as your reliable power solution partner, you now have access to our widest network of 250+ service centres in the country. Since 1984, Numeric has been enabling its clients to optimize their business with top- notch power solutions that promise seamless and clean power with controlled environmental footprints. We look forward to your continued patronage in the years to come. This manual contains detailed instructions on how to use, install and operate this product.

Disclaimer

  • The contents of this manual are bound to change without prior notice.
  • We have exercised reasonable care to give you an error-free manual. Numeric disclaims liability for any inaccuracies or omissions that may have occurred. If you find information in this manual that is incorrect, misleading or incomplete, we would appreciate your comments and suggestions.
  • Before you begin the installation of the product, please read this manual thoroughly. The warranty of this product is null and void if the product is abused/misused.

INTRODUCTION

Digital 600 EX is designed for personal computers. Equipping double boost and single buck AVR, Digital EX UPS can stabilize a wide voltage range from 140 to 300VAC. The fast charger recharge battery ensures that battery is always ready for power backup. Built-in DC start function and generator compatibility make UPS adapt to various operational conditions. The following points shows other handy features of Digital EX UPS.

  • Microprocessor control guarantees high reliability
  • Double boost & single buck AVR stabilize wide voltage fluctuations
  • Fast charger ensures battery readiness for power backup
  • DC start function
  • Generator compatibility
  • Auto restart while AC recovery
  • Compact size, lightweight

IMPORTANT SAFETY INSTRUCTIONS
Save these instructions: This manual contains important instructions for the model Digital 600 EX that should be followed during installation and maintenance of the UPS and batteries.

  • This UPS utilizes voltages that may be hazardous.
    Do not attempt to disassemble the unit. The unit contains no user-serviceable parts. Only factory service personnel may perform repairs.

  • Connection to any type of receptacle other than a 2-pole, 3-wire grounding receptacle may result in shock hazards as well as violate local electrical codes.

  • In the event of an emergency, turn the power switch to the “off” position and disconnect the power cord from the AC power supply to properly disable the UPS

  • Do not allow any liquids or any foreign object to enter the UPS. Do not place beverages or any other liquid-containing vessels on or near the unit.

  • This unit is intended for installation in a controlled environment (temperature-controlled, indoor area free of conductive contaminants). Avoid installing the UPS in locations where there is standing or running water, or excessive humidity.

  • Do not plug the UPS input into its output.

  • Do not attach a power strip or surge suppressor to the UPS.

  • Do not attach non-computer-related items, such as medical equipment, life-support equipment, microwave ovens, or vacuum cleaners to UPS.

  • To reduce the risk of overheating the UPS, do not cover the UPS’ cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat-emitting appliances such as space heaters or furnaces.

  • Unplug the UPS before cleaning and do not use liquid or spray detergent.

  • Do not dispose of batteries or throw batteries in a fire. The battery may explode.

  • Do not open or mutilate the battery or batteries. Released electrolytes are harmful to the skin and eyes. It may be toxic.

  • A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when working on batteries:

    • Remove watches, rings, or other metal objects from the hand.
    • Use tools with insulated handles.
    • Wear rubber gloves and boots.
    • Do not lay tools or metal parts on the top of the batteries.
    • Disconnect the charging source before connecting or disconnecting the battery terminal.
  • Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries.

  • When replacing batteries, replace them with the same type and number of sealed lead-acid batteries. The maximum ambient temperature rating is 40 0c.

  • This pluggable type-A equipment with the battery already installed by the supplier is operator-installable and may be operated by laymen.

  • During the installation of this equipment, it should be assured that the sum of the leakage currents of the UPS and the connected loads does not exceed 3.5 mA.

  • Beware of hazards that may arise through electric shocks. Also, while disconnecting this unit from the mains, may be available through. supply from the battery. The battery supply should be therefore disconnected
    in the plus and minus pole of the battery when maintenance or service work inside the UPS is necessary.

  • The main socket outlet that supplies to the UPS shall be installed near the UPS and shall be easily accessible.

SYSTEM DESCRIPTION

Front panel

NUMRIC-Digital-600-EX-UPS-FIG-2

Back panel

INSTALLATION AND OPERATION

Inspection
Remove the UPS from its packaging and inspect it for damage that may have occurred during shipping. If any damage is discovered, repack the unit and return it to the dealer from whom you had purchased.

Placement
Install the UPS unit in any protected environment that provides adequate airflow around the unit, and is free from excessive dust, corrosive fumes and conductive contaminants. Do not operate your UPS in an environment where the ambient temperature or humidity is high. On the other hand, place the UPS at least 20 cm away from the monitor to avoid interference.

Charging
This unit is shipped from the factory with its internal battery fully charged, however, some charge may be lost during shipping and the battery should be recharged prior to use. Plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged in for at least 8 hours with no load (no electrical devices such as computers, monitors, etc.) connected.

Connection
Plug the UPS into a 2-pole, 3-wire grounded receptacle. Then connect one computer-related device to each of the power receptacles supplied on the back panel.
Note: The circuit breaker rating of the branch circuit supplied from the mains input panel sizing must be 6 A/250 Vac under National Electrical Codes and Standards as per the schematic (based on
N.E.C NFPA 70 -2014; Reference: Article 240)

Note: Circuit Breaker rating of the Branch Circuit supplied from the mains input panel sizing must be 6 A/250 Vac in accordance with National Electrical Codes and Standards as per schematic (based on N.E.C NFPA 70 -2014; Reference: Article 240)

Turn On/Off
To turn on the UPS unit, press the power switch lightly. To turn off the UPS unit, press the power switch again.

DC Start

This series is equipped with DC Start. To start the UPS when AC utility power is not available, simply press the power switch.

Green Power Function
UPS is equipped with a Green Power function. If no load is connected, UPS will automatically shut down in 5 minutes for energy saving during power failure. The UPS will restart while AC recovery.

SPECIFICATION

Model Description Digital 600 EX
Capacity VA/W 600 VA/360 W
Input Voltage range 140-300 Vac
Frequency 50 Hz
Output Voltage 190-253 Vac
Voltage regulation (Batt. mode) 230 Vac +/- 10%
Frequency regulation (Batt. mode) 50 +/-1 Hz
Waveform Modified sine wave
Battery Battery type and number 12 V/7 Ah x 1 pc (sealed, lead-acid,

maintenance free, 6 cells battery)
Back up time (1 PC load)| 10 min
Recharge time| 4-8 hours to 90% after complete discharge
Transfer time| Typical| 4-8 ms, max 10 ms
Indicator| AC mode| Green lighting
Back up mode| Green flashing
Audible alarm| Back up mode| Sounds every 10 seconds
Low battery| Sounds every second
Overload| Sounds 0.5 seconds
Fault| Continuously sounds
Protection| Full protection| Discharge, overcharge and overload protection
Physical| Dimension (DXWXH)| 279 X 101 X 143 mm
Net weight| 4.23 kg
Environment| Operating environment| 0-40°C, 0-90% relative humidity (non- condensing)
Noise level| Less than 40 dB

Product specifications are subject to change without further notice

TROUBLESHOOTING

Use the following table to solve minor problems. If any abnormal situation occurs that are not listed above, please call service technician for assistance.

Problem Possible cause Remedy
No LED light on the front panel after pressing the power on/off switch. 1.
Battery weak Re-charge battery up to 4-6 hours
2. Battery defect Replace with the same type of battery
3. Power on/off switch is not firmly pressed. Press the power switch again
Alarm beeps continuously when utility power is normal Overload of the UPS

Verify that the connected load is equal to or less than the UPS capability as specified
Green LED flashes, and UPS keeps running in battery mode when utility power exists.| 1. Fuse blowout or breaker trips| Replace with same type of fuse or reset breaker.
2. Utility power fluctuation exceeds UPS voltage range| Normal condition. No action is needed.
3. Loosen power cord| Reconnect the power cord properly.
UPS provides inadequate run-time.| 1. Overload of the UPS| Remove some non- critical load
2. Battery voltage is too low| Charge battery 4-6 hours or more
3. Battery defect due to high-temperature environment, or improper operation of battery.| Replace with the same type of battery

CONTACT

Head Office

  • 10th Floor, Prestige Center Court, Office Block, Vijaya Forum Mall, 183, N.S.K Salai, Vadapalani, Chennai – 600 026.
  • Phone: +91 44 4656 5555

Regional Offices

  • New Delhi
    • B-225, Okhla Industrial Area,
    • 4th Floor, Phase-1,
    • New Delhi – 110 020.
    • Phone: +91 11 2699 0028
  • Kolkata
    • Bhakta Tower, Plot No. KB22,
    • 2nd & 3rd Floor, Salt Lake City, Sector – III, Kolkata – 700 098.
    • Phone: +91 33 4021 3535 / 3536
  • Mumbai
    • C/203, Corporate Avenue, Atul Projects, Near Mirador Hotel, Chakala,
    • Andheri Ghatkopar Link Road, Andheri (East), Mumbai – 400 099.
    • Phone: +91 22 3385 6201
  • Chennai
    • 10th Floor, Prestige Center Court, Office Block, Vijaya Forum Mall, 183, N.S.K Salai, Vadapalani,
    • Chennai – 600 026.
    • Phone: +91 44 3024 7236 / 200

Branch Offices

  • Chandigarh
    • SCO 4, First Floor, Sector 16, Panchkula, Chandigarh – 134 109.
    • Phone : +91 93160 06215
  • Dehradun
    • Unit-1 and 2, Chakrata Road,
    • Vijay Park Dehradun – 248001. Uttrakhand
    • Phone: +91 135 661 6111
  • Jaipur
    • Plot No. J-6, Scheme-12B,
    • Sharma Colony, Bais Godown,
    • Jaipur – 302 019.
    • Phone : +91 141 221 9082

Contact us.:

FAQ

  • Q: What should I do if the UPS is damaged during shipping?
    • A: If any damage is discovered, repack the unit and return it to the dealer from whom you purchased it.
  • Q: How long should I leave the UPS plugged in to charge fully?
    • A: Leave the UPS plugged in for at least 8 hours with no load connected for full charging.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

NUMRIC User Manuals

Related Manuals