HESSAIRE 36D370S Cabinet Exhaust Fans Instruction Manual

June 3, 2024
HESSAIRE

HESSAIRE-logo

HESSAIRE 36D370S Cabinet Exhaust Fans

HESSAIRE-36D370S-Cabinet-Exhaust-Fans-product

Model Numbers Covered:
36D370S, 36D370TS, 36DL750S, 36DL750TS, 36XL550S, 36XL750S, 36XL750TS, 42DL750S, 42DL750TS, 42XL750S, 42XL750TS, 42XL1125S, 42XL1125TS, 48XL750S, 48XL750TS, 48XL1125S, 48XL1125TS

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the equipment described within this manual. Carefully follow all safety information.

Getting Started

Tools/Materials Needed:

  • Drill/drill bits
  • Saw
  • Level
  • Screwdriver(s)
  • 5/16” nut driver
  • Construction screws
  • Caulk or sealant

Inspection:

After unpacking your fan, carefully inspect for any damage that may have occurred during transit. Inspect for loose, missing or damaged parts. If there is physical damage to any parts of the fan, a freight claim must be filed with the carrier. Check to assure that all bolts, screws and set screws are securely tightened and have not become loose during transit. Retighten as required. Rotate propeller by hand to assure it turns freely.

General Safety Instructions

Warning: Before installing or servicing, always lock out and tag power source. Do not rely on a switch as the only means of disconnecting power. Failure to disconnect power can result in fire, electrical shock or serious injury. Motor will restart without warning after thermal protector trips. Do not touch an operating motor as it may be hot enough to cause injury. Do not place any body parts or objects in fan or drive components while fan is connected to a power source.

Caution:

  1. Read and follow all instructions, cautions, dangers and warnings. Failure to do so could result in personal injury, death or property damage.
  2. Make sure the electrical power source conforms to the requirement of the fan(s) as well as local codes.
  3. Electrical connections, installation and maintenance must be done by qualified electrical personnel in accordance with all applicable codes and ordinances.
  4. Unit must be adequately grounded.
  5. To reduce the risk of fire or electrical shock, do not expose this fan to water.
  6. Do not touch electrically live components.
  7. Free rotation of the propeller is critical. It must not touch any part of the venturi or framework.
  8. Assure that all power cords do not come in contact with any sharp edges, hot surfaces or chemicals. Immediately replace any damaged cords.
  9. Before operating your new fan, ensure propeller is torqued properly and all fasteners, screens and shutters are securely in place.

OSHA-compliant guards must be in place when fan is installed within 7ft of the floor or working level.

Specifications

Model| Prop

Dia.

|  | Dimension (In.)|  | Rough-in Opening (In.)| Unit Weight

(lbs)

---|---|---|---|---|---|---
A| B| C| D| Height| Width
36D370S| 36”| 40 1/8| 40 1/8| 14| 16| 40 3/4| 40 3/4| 110
36D370TS| 36”| 40 1/8| 40 1/8| 14| 16| 40 3/4| 40 3/4| 110
36DL750S| 36”| 40 1/8| 40 1/8| 24| 26| 40 3/4| 40 3/4| 130
36DL750TS| 36”| 40 1/8| 40 1/8| 24| 26| 40 3/4| 40 3/4| 130
36XL550S| 36”| 40 1/8| 40 1/8| 24| 26| 40 3/4| 40 3/4| 130
36XL750S| 36”| 40 1/8| 40 1/8| 24| 26| 40 3/4| 40 3/4| 155
36XL750TS| 36”| 40 1/8| 40 1/8| 24| 26| 40 3/4| 40 3/4| 155
42DL750S| 42″| 46 1/8| 46 1/8| 24| 26| 47| 47| 150
42DL750TS| 42″| 46 1/8| 46 1/8| 24| 26| 47| 47| 150
42XL750S| 42″| 46 1/8| 46 1/8| 24| 26| 47| 47| 175
42XL750TS| 42″| 46 1/8| 46 1/8| 24| 26| 47| 47| 175
42XL1125S| 42″| 46 1/8| 46 1/8| 24| 26| 47| 47| 190
42XL1125TS| 42″| 46 1/8| 46 1/8| 24| 26| 47| 47| 190
48XL750S| 48″| 52 1/8| 52 1/8| 24| 26| 53| 53| 190
48XL750TS| 48″| 52 1/8| 52 1/8| 24| 26| 53| 53| 190
48XL1125S| 48″| 52 1/8| 52 1/8| 24| 26| 53| 53| 205
48XL1125TS| 48″| 52 1/8| 52 1/8| 24| 26| 53| 53| 205

HESSAIRE-36D370S-Cabinet-Exhaust-Fans-fig1

Fan Installation

  • For framing dimensions, refer to rough-in opening height and width shown in the specifications above.
  • Fan is designed to mount in wall with air discharging towards the outside. Center fan weight in opening.
  • Position the fan in the wall with the discharge shutter facing to the outside of the building. Louvers hang down, closed completely.
  • Ensure the fan is fastened securely in the opening to avoid excess “rattling” or vibration using proper fasteners. Fasteners not included.
  • An aluminum or iron angle is recommended on sides/top/bottom of fan to attach fan to wall and help close rough-in gap around fan. Angle
  • should attach to fan housing and wall opening frame to securely hold fan in place.
  • Fan support bracing(wall brackets) should be used to properly support the portion of fan that hangs out of opening.
  • Seal around fan to prevent air leakage.
  • Refer to motor nameplate for wiring diagram.

Repair Parts Illustration

HESSAIRE-36D370S-Cabinet-Exhaust-Fans-fig2

Belt Drive Fans

No Description 36XL550S 36XL750S 36XL750TS
1 Motor A550-4CE A750-4CE A750-4T
2 Prop 9001565
3 Shutter SA36 SA36 SA36
4 Bearings UCP20516

LDK

| UCP20516

LDK

| UCP20516

LDK

5| Tensioner| BTI| BTI| BTI
6| Belt| AX51| –| –
7| Motor Sheave| AK3958| –| –
8| Driven Pulley| AKN9410| –| –
9| Shaft| FS7.5| FS7.5| FS7.5
10| Screen| 36SCREEN| 36SCREEN| 36SCREEN
No| Description| 42XL750S| 42XL750TS| 42XL1125S| 42XL1125TS| 48XL750S| 48XL750TS| 48XL1125S| 48XL1125TS
---|---|---|---|---|---|---|---|---|---
1| Motor| A750-4CE| A750-4T| A1125-4| A1125-4T| A750-4CE| A750-4T| A1125-4| A1125-4T
2| Prop| 9001398| 9001398| 9001398| 9001398| –| –| –| –
3| Shutter| SA42| SA42| SA42| SA42| SA48| SA48| SA48| SA48
4| Bearings| UCP20516

LDK

| UCP20516

LDK

| UCP20516

LDK

| UCP20516

LDK

| UCP20516

LDK

| UCP20516

LDK

| UCP20516

LDK

| UCP20516

LDK

5| Tensioner| BTI| BTI| BTI| BTI| BTI| BTI| BTI| BTI
6| Belt| AX53| AX53| –| –| –| –| –| –
7| Motor Sheave| AK2858| AK2858| –| –| –| –| –| –
8| Driven Pulley| AKN9410| AKN9410| –| –| –| –| –| –
9| Shaft| FS7.5| FS7.5| FS7.5| FS7.5| FS7.5| FS7.5| FS7.5| FS7.5
10| Screen| 42SCREEN| 42SCREEN| 42SCREEN| 42SCREEN| 48SCREEN| 48SCREEN| 48SCREEN| 48SCREEN
No| Description| 36D370S| 36D370TS| 36DL750S| 36DL750TS| 42DL750S| 42DL750TS| |
---|---|---|---|---|---|---|---|---|---
1| Motor| B370-8ENY| B370-8T| A750-8VE| A750-8TVE| A750-8VE| A750-8TVE| –| –
2| Prop| 9001672| 9001672| –| –| –| –| –| –
3| Shutter| SA36| SA36| SA36| SA36| SA42| SA42| –| –
4| Screen| 36SCREEN| 36SCREEN| 36SCREEN| 42SCREEN| 42SCREEN| 42SCREEN| –| –

Direct Drive Fans

Note: Prop drawing does not represent all models. Number of fan blades will vary by model.HESSAIRE-36D370S-Cabinet-Exhaust-Fans-
fig3

Performance

Model

|

HP

|

F.L.A.

|

Volt.

|

Ph

|

Hz

| Motor

RPM

| CFM| Dbs @ 7ft

0.0SP

---|---|---|---|---|---|---|---|---
0.0″ SP| 0.1″ SP| 0.2″ SP| 0.3″ SP
36D370S| 1/2| 5.2/2.8-2.6| 115/208-230| 1| 60| 825| 10,300| 8,700| 7,180| –| 76
36D370TS| 1/2| 2.3-2.2/1.1| 208-230/460| 3| 60| 825| 10,315| 8,730| 7,185| –| 76
36DL750S| 1| 11.0/5.8-5.5| 115/208-230| 1| 60| 825| 12,510| 10,635| 8,830| 6,045| 78
36DL750TS| 1| 4.8-4.6/2.3| 208-230/460| 3| 60| 825| 12,505| 10,625| 8,825| 6,035| 78
36XL550S| 3/4| 6.4/3.4-3.2| 115/208-230| 1| 60| 1725| 11,010| 9,580| 8,210| 5,470| 73
36XL750S| 1| 9.4/5.0-4.7| 115/208-230| 1| 60| 1725| 12,005| 10,450| 9,015| 6,675| 77
36XL750TS| 1| 3.8-3.6/1.8| 208-230/460| 3| 60| 1725| 12,010| 10,460| 9,025| 6,690| 77
42DL750S| 1| 11.0/5.8-5.5| 115/208-230| 1| 60| 825| 15,570| 12,540| 11,140| 6,905| 80
42DL750TS| 1| 4.8-4.6/2.3| 208-230/460| 3| 60| 825| 15,565| 12,530| 11,135| 6,900| 80
42XL750S| 1| 9.4/5.0-4.7| 115/208-230| 1| 60| 1725| 15,450| 12,490| 11,135| 7,080| 79
42XL750TS| 1| 3.8-3.6/1.8| 208-230/460| 3| 60| 1725| 15,455| 12,495| 11,135| 7,085| 79
42XL1125S| 1 1/2| 13.2-13.0| 208-230| 1| 60| 1725| 18,150| 15,695| 12,780| 10,420| 81
42XL1125TS| 1 1/2| 5.0-4.8/2.4| 208-230/460| 3| 60| 1725| 18,145| 15,690| 12,770| 10,415| 81
48XL750S| 1| 9.4/5.0-4.7| 115/208-230| 1| 60| 1725| 19,020| 17,015| 14,670| 11,070| 80
48XL750TS| 1| 3.8-3.6/1.8| 208-230/460| 3| 60| 1725| 19,035| 17,030| 14,685| 11,080| 80
48XL1125S| 1 1/2| 13.2-13.0| 208-230| 1| 60| 1725| 23,740| 21,545| 18,435| 13,930| 82
48XL1125TS| 1 1/2| 5.0-4.8/2.4| 208-230/460| 3| 60| 1725| 23,735| 21,555| 18,450| 13,985| 82

Troubleshooting Guide

Symptom Possible Cause(s) Corrective Action
Fan will not start 1. Tripped circuit breaker 1. Reset circuit breaker
  2. Defective motor 2. Repair or replace
  3. Incorrectly wired 3. Shut off power, check for proper connections
  4. Electricity turned off 4. Contact local power company
Excessive noise or vibration 1. Blade is hitting housing 1. Free blade of

obstruction
 | 2. Blade is bent| 2. Replace blade
 | 3. Fan not securely anchored| 3. Secure properly
 | 4. Bad/noisy motor bearings| 4. Replace motor
Insufficient airflow| 1. Incorrect voltage applied| 1. Wire properly
 | 2. Defective motor| 2. Replace motor
 | 3. Propeller is damaged| 3. Replace propeller
 | 4. Airflow is blocked| 4. Remove obstructions
 | 5. Not enough intake air| 5. Add additional air intake openings
 | 6. Fan is dirty| 6. Clean fan guards/screens, motor and propeller
Motor overheats or trips out| 1. Over/under line voltage| 1. Contact local power company
 | 2. Defective motor| 2. Replace motor
 | 3. Fan is dirty.| 3. Clean fan guards/screens, motor and propeller
 | 4. Not enough intake air| 4. Add additional air intake openings

Maintenance

  • Periodic maintenance schedules should be set to assure reliability and performance of the fan. This maintenance should include inspection of all fasteners & drive components, checking propeller torque and proper cleaning of the complete fan assembly.
  • Check for excessive vibration while fan is running.
  • Periodically inspect and tighten all set screws and hardware.
  • Ensure all mounting hardware, chains, etc. are properly secured.
  • Motors feature permanently sealed ball bearings and require no further lubrication.
  • The fan propeller should be periodically cleaned to assure proper balance and performance.

MH-0004 Rev. 053122 www.air-movement.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

HESSAIRE User Manuals

Related Manuals