Xpelair DX100TS 100mm 4 Axial Bathroom Extractor Fan with Timer Instruction Manual

June 1, 2024
Xpelair

Xpelair-LOGO

Xpelair DX100TS 100mm 4 Axial Bathroom Extractor Fan with Timer

Xpelair-DX100TS-100mm-4-Axial-Bathroom-Extractor-Fan-with-Timer-PRODUCT-
IMAGE

Specifications

  • Model: Xpelair Simply SilentTM DX100
  • Variants: DX100R, DX100TR, DX100S, DX100TS, DX100HPTR,
  • DX100HPTS, DX100PR, DX100HTR, DX100PS, DX100HTS, DX100PIRR, DX100PIRS
  • Overall Dimensions (mm): Refer to manual for detailed dimensions
  • Installation: Refer to manual for installation instructions
  • Wiring: G1 Wiring and setting up instructions provided
  • Humidity Setting: Adjustable with factory settings
  • Run on Timer Setting: Adjustable with detailed instructions

Installation Instructions

  • Before installing the Xpelair Simply SilentTM DX100 fan, ensure that the fan is not mounted immediately above a cooker hob or eye level grill. For devices with non-balanced flue, ensure there is enough replacement air to prevent fumes being drawn down the flue during operation. Refer to Building Regulations for specific requirements.
  • Observe all requirements related to exhaust air discharge and intake flow rates, especially when dealing with corrosive atmospheres
  • Refer to the manual for specific installation steps, including back plate fixing positions and front cover removal.

Product Usage Instructions

Adjusting Humidity Setting
To adjust the humidity setting, follow these steps:

  1. Access the humidity setting controls on the fan.
  2. Adjust the humidity setting as per your preference.
  3. Factory settings can be restored if needed.

Adjusting Run on Timer Setting
To adjust the run on timer setting, follow these steps:

  1. Locate the run on timer controls on the fan.
  2. Set the desired run on timer duration.
  3. Follow detailed instructions in the manual for further adjustments.

FAQ

  • Q: Can the Xpelair Simply SilentTM DX100 be installed in corrosive atmospheres?
    A: While the fan can handle some level of corrosive atmospheres, it is recommended to avoid prolonged exposure to such environments. Ensure proper ventilation and maintenance in corrosive conditions.

  • Q: Are there specific requirements for installing the fan above certain appliances?
    A: Yes, avoid mounting the fan directly above a cooker hob or eye level grill. For devices with non-balanced flue, ensure adequate replacement air to prevent fumes being drawn down the flue during operation.

Installation and Maintenance Instructions

  • DX100R (93005AW)
  • DX100S (93025AW)
  • DX100TR (93006AW)
  • DX100TS (93026AW)
  • DX100PR (93007AW)
  • DX100PS (93027AW)
  • DX100HTR (93008AW)
  • DX100HTS (93028AW)
  • DX100HPTR (93009AW)
  • DX100HPTS (93029AW)
  • DX100PIRR (93010AW)
  • DX100PIRS (93030AW

This appliance is intended for connection to fixed wiring. Check that the electrical rating shown on each fan matches the mains supply.

  • THE APPLIANCE IS DOUBLE INSULATED AND DOES NOT REQUIRE AN EARTH CONNECTION. All installations must be supervise by a qualified electrician. Installations and wiring must conform to current IEE Regulations (UK), Loc: or appropriate regulations (other countries).
  • This appliance is intended for connection to fixed wiring. Check that the electrical rating shown on each fan matches the mains supply. THE APPLIANCE IS DOUBLE INSULATED AND DOES NOT REQUIRE AN EARTH CONNECTION. All installations must be supervise by a qualified electrician. Installations and wiring must conform to current IEE Regulations (UK), loc: or appropriate regulations (other countries).
  • All Xpelair Simply Silent™ DX100 AC fans have the following features:
  • Two speed extraction (Selectable at installation) DX100R/DX100S – Operate the fan using an on/off switch (not supplied).
  • DX100TR/DX100TS* – Built-in timer operates fan for a preset delay from 30 seconds to 30 minutes.
  • DX100PR/DX100PS – Operate the fan using an integral pull-cord.
  • DX150HTS/DX150HTR* – Operates when triggered automatically by the integral humidity sensor, or by using an external on/off switch (not supplied).
  • In automatic mode: the built-in timer automatically operates the fan for a pre-set delay time from 30 seconds to 30 minutes once humidity drops below the pre-set Relative Humidity (RH) value.
  • External operation: When switched off using the external on/off switch the fan continues to run for the preset delay from 30 seconds to 30 minutes.
  • DX100HPTR/DX100HPTS* – Operates when triggered automatically by the integral humidity sensor, by using an external on/off switch (not supplied), or by using the integral pull cord switch.
  • In automatic mode: The built in timer automatically operates the fan for the pre-set delay time from 30 seconds to 30 minutes once humidity drops below the pre-set Relative Humidity (RH) value.
  • External operation: When switched off using either the external on/off switch or the integral pull cord switch the fan continues to run for the pre-set delay from 30 seconds to 30 minutes.
  • DX100PIRR/DX100PIRS* – An integral body movement sensor operates the fan as long as movement is detected. The built-in timer automatically operates the fan for a pre-set delay of up to 20 minutes.
  • Factory settings: Timer 15 minutes, RH 75%
  • Where to locate the fan.
  • Locate it as high as possible.
  • At least 110mm from the edges of the mounting surface to the centre of the hole.
  • As far away as possible from and opposite to the main source of air replacement to ensure airflow across the room (e.g. opposite the internal doorway).
  • Near the source of steam or odours.
  • Not where ambient temperatures are likely to exceed 50°C.
  • If installed in a kitchen fans must not be mounted immediately above a cooker hob, or eye level grill.
  • If installing in a room containing a fuel burning device which has a non-balanced flue, it is the installer’s responsibility to ensure that there is enough replacement air to prevent fumes being drawn down the flue when the fan is operating up to maximum extract. Refer to Building Regulations for specific requirements.
  • Exhaust air must not be discharged into a flue used for exhausting of fumes from appliances supplied with energy other than electric. Requirements of all authorities concerned must be observed for exhaust air discharge and intake flow rates.
  • Not suitable for use in possible chemical corrosive atmospheres.

Installation

  • What the installer will need.
  • 3mm electrician’s screwdriver and No.1 or 2 Pozidrive screwdrivers.

Overall Dimensions (mm)

Xpelair-DX100TS-100mm-4-Axial-Bathroom-Extractor-Fan-with-Timer-
\(2\)

Back plate fixing positions

C Front Cover Removal Xpelair-DX100TS-100mm-4-Axial-Bathroom-Extractor-Fan-
with-Timer- \(8\) Xpelair-
DX100TS-100mm-4-Axial-Bathroom-Extractor-Fan-with-Timer-
\(9\) Xpelair-DX100TS-100mm-4
-Axial-Bathroom-Extractor-Fan-with-Timer- \(10\) Xpelair-DX100TS-100mm-4-Axial-Bathroom-Extractor-Fan-
with-Timer- \(11\) Xpelair-
DX100TS-100mm-4-Axial-Bathroom-Extractor-Fan-with-Timer-
\(12\) Xpelair-DX100TS-
100mm-4-Axial-Bathroom-Extractor-Fan-with-Timer- \(13\) Xpelair-DX100TS-100mm-4-Axial-Bathroom-Extractor-Fan-
with-Timer- \(14\)

If wall mounting the fan, you will also need

  •  A 100mm diameter prepared hole.
  • An appropriate external Wall Grille and 0100mm wall sleeve duct (supplied). Cut ducting to correct length if required. The wall tube supplied is telescopic and can be extended to 300mm maximum.

If ceiling mounting the fan, you will also need:

  • A 100mm diameter prepared hole.
  • A 100mm diameter prepared hole for the external grille, ideally positioned to allow condensation to run away from the first bend in the duct towards the external grille.

Appropriate ancillaries for termination. These items are available from Xpelair: 1.

  1. 3m flexible ducting Ref: 89663AA. If the duct passes through a cold space use insulated duct ref: 89847AA.
  2. Soffit Grille Ref: 89742AW

If window mounting the fan, you will also need:
SSWIN – Simply Silent Window Kit. Ref: 92996AA

  • Installing the isolating switch and cables. A means for disconnection in all poles must be incorporated in the fixed wiring in accordance with wiring regulations
  • If metal switch boxes are used, earthing regulations must be followed.
  • The cross-sectional area of the supply cord used should be ranged from 1-1.5mm.
  • DX100R / DX100S / DX100PR / DX100PS /| DX100PIRR / DX100PIRS – 2 core,
  • DX100TR / DX100TS / DX100HTR / DX100HTR / DX100HPTR / DX100HPTS – 3 core. * If wiring to remote switch.
  1. Check that the electrical rating shown inside the back-plate matches your mains supply.

  2. Check there are no buried pipes or cables e.g. electricity, gas, water behind the switch location (in the wall or above the ceiling). If in doubt, seek professional advice.

  3. Isolate the mains supply.

  4. Lay in the cable from the isolating switch to the fan location via the on/off switch (if required).

  5. Lay in the cable from the isolating switch to the joint of connection to the Maine cannily
    Warning: Do not make any connections to the electrical supply at this stage.

  6. Install the isolating switch and on/off switch (if required).

  7. Make all connections within the isolating switch and the on/off switch (if required).

Wet Rooms: On/Off switch must be situated so that it cannot be touched by persons making use of the bath or shower. For Australia Only – DX100R / DX100S / DX100PR / DX100PS / DX100PIRR / DX100PIRS Connection to the supply can be made by a flexible 2-core cable complete with 3 pin plug for insertion into an approved 10A GPO or directly wired through an approved 10A wall mounted surface switch with at least 3mm clearance between contacts.

Preparing the Fan for installation

  1. Remove the front cover by depressing the latch on the underside of the cover and pulling off the front cover from the bottom (See Figure C).
    If working above ground floor level, safety precautions must be observed. Mark the position of the back-plate

  2. Hold the back-plate so that the level line marked on it is orientated horizontally.

  3. Carefully insert the fan tube into the wall duct.

  4. Mark on the wall the positions of the fixing holes in the back-plate

  5. Remove the back plate from the ducting.

  6. Drill screw holes in these positions if necessary, and fit wall pluas and screws as required.
    If installing in a ceiling, appropriate termination ancillaries are required. Follow instructions provided. Mount the back-plate.

  7. Push the ribbed gasket onto the duct section of the back plate (see Figure D).

  8. Push the larger diameter piece of the telescopic wall tube onto the ribbed gasket. Cut the tube to the required size first if necessary.

  9. Feed the mains cable through the cable entry hole in the back plate to the terminals.

  10. Insert the fan tube into the wall duct/ceiling as before.

  11. Fasten the back-plate to the wall/ceiling using appropriate fasteners supplied. See figure A.

  12. If using screws, do not over tighten.
    Mount the back draft shutter

  13. Peel the backing from the foam strip supplied and attach it around the outside lip on the backdraft shutter.

  14. Go outside. Holding open the top and bottom vanes insert the lip into the wall duct.

  15. Making sure that the back draft shutter is level, mark the positions of the two fixing holes in the top right hand and bottom left hand corners.

  16. Remove the back draft shutters from the  wall duct.

  17. Drill screw holes in marked positions and fit the remaining wall plugs.

  18. Holding open the top and bottom vanes, refit the back draft shutter and fasten it to the wall using the screws. Do not overtighten screws.

  19. Make sure that the vanes open and shut fully. Wire the electrical connections.

  20. Make sure the mains supply is isolated. Switch off the mains electrical supply and remove fuses.

  21. Feed the cable to the terminal block.
    Wire the fan as shown in Figure H using the diagram appropriate to the fan model.

  22. Connect the cable from the isolating switch to the electrical supply wiring.

Xpelair-DX100TS-100mm-4-Axial-Bathroom-Extractor-Fan-with-Timer-
\(15\) Xpelair-DX100TS-
100mm-4-Axial-Bathroom-Extractor-Fan-with-Timer- \(16\) Xpelair-DX100TS-100mm-4-Axial-Bathroom-Extractor-Fan-
with-Timer- \(17\)

Fan Settings

SPEED SETTING

The fans are factory set to low speed, but have two speed settings for different applications. Select either high or low speed by connecting the jumper between the centre and high or low speed pin on the jumper (see Figure G). DX100TR / DX100TS / DX100PIRR / DX100PIRS only.

To adjust the over-run period turn the control 1) clockwise to increase and anti-clockwise to decrease — see Failure

  • DX100TR / DX100TS / DX100PIRR / DX100PIRS only.
  • To adjust the over-run period turn the control (1) clockwise to increase and anti-clockwise to decrease – see Figure F.
  • DX100HTR / DX100HTS / DX100HPTR / DX100HPTS only – see figures F and G.
  • The pre-set humidity operation is factory set at approximately 75% Relative Humidity (RH), but can be adjusted between 65% and 85% RH by control H.
  • The over-run timer is factory set at 15 minutes but can be adjusted from 30 seconds to 30 minutes by control T.
  • Turn the controls clockwise to increase RH or time and anti-clockwise to decrease.

Using the fa n

DX100R / DX100S Only

  • Operate the fan using the on/off switch (not supplied). Repeat to switch off. DX100TR / DX100TS Only
  • Operate the fan using an on/off switch (not supplied). Note – the fan may take up to 10 seconds to turn on once the switch has beer operated. When the switch is turned off, the fan continues to operate for the set time delay. To adjust the over-run period, turn the control “T” clockwise to increase and anti- clockwise to decrease – see Figure F. DX100PR / DX100PS Only
  • Operate the fan by pulling and releasing the cord. Repeat to switch off. DX100HTR / DX100HTS Only.
  • Automatic mode – The fan automatically adjusts to slow changes in natural humidity levels without operating the fan. If the humidity levels increase at a rate slower than 5% RH in 5 minutes, up to the pre-set humidity level, the fan will not be triggered by humidity. This is to prevent nuisance triggering of the fan. If humidity levels increase quicker than 5% RH in 5 minutes the fan will operate. When relative humidity drops the fan continues to operate for the adjustable time delay.
  • External operation – Use the external on/off switch. When the fan is switched off, the fan continues to operate for the adjustable time delay then goes into automatic mode. DX100HPTR / DX100HPTS Only.
  • Automatic mode – The fan automatically adjusts to slow changes in natural humidity levels without operating the fan. If the humidity levels increase at a rate slower than 5% RH in 5 minutes, up to the pre-set humidity level, the fan will not be triggered by humidity. This is to prevent nuisance triggering of the fan. If humidity levels increase quicker than 5% RH in 5 minutes the fan will operate. When relative humidity drops the fan continues to operate for the adjustable time delay.
  • External operation – Use the external on/off switch. When the fan is switched off, the fan continues to operate for the adjustable time delay then goes into automatic mode.
  • Pull Cord operation – Use the integral pull cord switch. When the fan is switched off, the fan continues to operate for the adjustable time delay then goes into automatic mode.
  • DX100PIRR / DX100PIRS Only.
  • The sensor detects movement in the room and activates the fan. When movement is sensed, the fan will run for a pre-set over-run period and any further movement sensed will re-start the sequence. This ensures that the room is only ventilated during and immediately after use.
  • When the fan is first installed it will run for the time set by the overrun timer.
  • After this time, if no movement is sensed the fan will go into stand-by mode.

All Fans
Re-fit the front cover by hooking in the top first, and then swing the cover down to clip into place.

Cleaning (recommended once a month)

  1.  Before cleaning, isolate the fan completely from the mains supply.
  2. Remove the front cover by depressing the latch on the underside of the cover and pulling off the front cover from the bottom.
  3. To clean the front cover, either wipe it with a damp, lint free cloth or wash it with warm soapy water. Thoroughly dry the front cover and refit.
  4. Do not immerse the fan in water or other liquids to clean any other parts of the fan.
  5. Do not use strong detergents, solvents or chemical cleaners
  6. Allow fan to dry thoroughly before use.
  7. Apart from cleaning, no other maintenance is required.

Disposal

  • This product should not be disposed of with household waste.
  • Please recycle where facilities exist.
  • Check with your local authority for recycling advice.

Guarantee

  • UK only We, Glen Dimplex Heating & Ventilation provide a guarantee against faulty parts and manufacture for a period of 2 years from the date of purchase. In the unlikely event of a product breakdown during the guarantee period the product should be returned to the place of purchase or to Glen Dimplex Heating & Ventilation.
  • Exclusions
    • This guarantee does not cover compensation for the loss of the product or consequential loss of any kind.
    • Damage or defects to the product arising from incorrect installation or lack of maintenance.
    • Transportation costs.

This guarantee does not affect your statutory rights

Technical advice and service

  • Customers outside UK – see international below
  • United Kingdom Xpelair have a comprehensive range of services including:
  • Free technical advice help-desk from Engineers on all aspects of ventilation.
  • Free design service, quotations and site surveys.
  • Service and maintenance contracts to suit all requirements.
  • Glen Dimplex UK Ltd, Millbrook House, Grange Drive, Hedge End, Southampton, SO30 2DF
  • [email protected]
  • +44 (0) 344 879 3588
  • www.xpelair.co.uk
  • Ireland
  • Glen Dimplex Europe Limited, Airport Road, Cloghran, Co. Dublin, K67 VE08 [email protected] +353 (0)1 8523400
  • International Guarantee: Contact your local distributor or Xpelair direct for details.
  • Technical Advice and Service: Contact your local Xpelair distributor.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Xpelair User Manuals

Related Manuals