Xpelair VX100P SP 4 Inch 100mm Single Speed Axial Fan Instructions
- June 13, 2024
- Xpelair
Table of Contents
- VX100P SP 4 Inch 100mm Single Speed Axial Fan
- Installing the fan
- Description
- What the installer will need
- Installing the isolating switch and cables
- Preparing the hole
- Wire the electrical connections
- Cleaning (recommended once a month)
- Warranty.
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Toilet/Bathroom 100mm/4″ Fan Range
Retain for future reference
VX100P SP 4 Inch 100mm Single Speed Axial Fan
Installation and maintenance instructions
VX100……………………. Standard
VX100 P…………………. Pull Cord
VX100T……………… Timer
Xpelair Toilet/Bathroom Fans VX100, VX100P, VX100T, installation & operating
instructions
Please leave this leaflet with the fan for the benefit of the user
Installing the fan
These appliances are intended for connection to fixed wiring. Check that the
electrical rating shown on each fan matches the mains supply.
THESE APPLIANCES ARE DOUBLE INSULATED AND DO NOT REQUIRE AN EARTH CONNECTION.
All installations must be supervised by a qualified electrician. Installations
and wiring must conform to current IEE Regulations (UK), local or appropriate
regulations (other countries).
This appliance is not intended for use by persons (including children and the
Infirm) with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their
safety.
Children should be supervised to ensure that they do not play with the
appliance.
If you have any queries before installing these products or after they have
been installed, call the Xpelair Technical Hotline +44 (0) 344 879 3588.0ur
engineers are there to help you during normal office hours (UK only)
Customers outside the UK should contact your local Xpelair distributor.
Description
Xpelair fans have the following features:
- Universal mounting kit allows window/ wall panel/ ventilation shaft/ ceiling mounting options.
- Single speed extraction VX100
- Operate the fan using an on/off switch (not supplied).
VX100P
- Operate the fan using integral pull cord. VX100T
- Built-in timer automatically operates fan for a preset delay of up to 30 minutes.
What the installer will need
- A means for disconnection in all poles must be Incorporated in the fixed wiring in accordance with the wiring rules.
- If metal switch boxes are used, earthing regulations must be followed.
- Suitably rated 2-core cable (VX100, VX100P).
- Suitably rated 3-core cable 0.0(1001).
- 3mm electrician’s screwdriver and no.1 or 2 Pozdriv screwdrivers.
- A wall or ceiling on/off switch with built-in indicator light (VX100, VX1001).
- To prevent a possible hazardous situation from water ingress, a condensation trap (Xpelair no. XCT100) must be fitted as close as possible to the fan in all situations where any section of the duct work Is positioned higher than the fan itself.
If wall mounting the fan, you will also need
- Masonry drill, hammer & chisel (or core drill equipment if available).
- Mortar to make good the hole if required.
If window mounting the fan
- You will need a window pane between 3mm and 6mm thick (preferably 4mm).
- Do not install in glass 3mm thick if the window pane area is more than 0.2sq.m.
- If installing in sealed double glazing, a specially manufactured unit should be obtained from the glazing manufacturer. You will also require a special kit, Xpelair Cat. ref. DXDG.
- If installing In sash windows, you should mount the fan in the upper window. Secure the upper sash in the closed position and fit stops just below the level of the fan, to prevent damaging it when the sash is raised.
- If installing in a panel which is between 9mm and 46mm thick, you will need a special kit Xpelair Cat ref. DXDG. Do not Install these fans in a panel which is more than 46mm thick
If ceiling mounting the fan
You will need to use the appropriate ancillaries for termination. These items
are available from Xpelair.
- WTIO -Termination ducting kit.
- CFWG100 – Soffit board termination grille (white or brown).
- FD100 / 3 and FD100 / 6 – Flexible ducting.
Where to locate the fan
- Locate it as high as possible.
- At least 110mm from the edges of the mounting surface to the centre of the hole.
- As far away as possible from and opposite to the main source of air replacement to ensure airflow across the room (e.g. opposite the internal doorway).
- Near the source of steam or odours.
- Not where ambient temperatures are likely to exceed 50˚C.
- If installed in a kitchen fans must not be mounted immediately above a cooker hob, or eye level grill.
- If installing in a room containing a fuel burning device which has a non-balanced flue, it is the installer’s responsibility to ensure that there is enough replacement air to prevent fumes being drawn down the flue when the fan is operating up to maximum extract.
- Refer to Building Regulations for specific requirements.
- Exhaust air must not be discharged into a flue used for exhausting of fumes from appliances supplied with energy other than electric. Requirements of all authorities concerned must be observed for exhaust air discharge and intake flow rates.
- When intended for use in possible chemical corrosive atmospheres, consult out Technical Service Department. (For overseas markets contact your local Xpelair distributor).
Installing the isolating switch and cables
- Check that the electrical rating shown inside the back plate matches your mains supply.
- Check there are no buried pipes or cables e.g. electricity, gas, water behind the switch location (in the wall or above the ceiling). If in doubt, seek professional advise.
- Isolate the mains supply.
- Lay in the cable from the isolating switch to the fan location via the on/off switch (if required).
- Lay in the cable from the isolating switch to the point of connection to the mains supply.
- Install the isolating switch and on/off switch (if required).
- Make all connections within the isolating switch and the on/off switch (if required).
Note: on/off switch must be situated so that it cannot be touched by
persons making use of the bath or shower.
WARNING : DO NOT MAKE ANY CONNECTIONS TO THE ELECTRICAL SUPPLY AT THIS
STAGE.
For Australia only (VX100 & VX100P)
Connection to the supply can be made by a flexible 2-core cable complete with
3 pin plug for insertion into an approved 10 amp GPO or directly wired through
an approved 10A wallmounted surface switch with at least 3mm clearance between
contacts.
For Australia only (VX100T)
These models are permanently connected to the supply and operation is
controlled by a remote switch. They should be directly wired to the supply
through an approved 10amp wall mounted surface switch with at least 3mm
clearance between contacts.
Preparing the hole
If working above ground floor level, appropriate safety precautions must be
observed.
WARNING: EYE PROTECTION MUST BE WORN DURING ALL DRILLING AND CHISELLING
OPERATIONS.
If installing in a wall
-
Check there are no buried pipes or cables in the wall or obstructions on the outside e.g. electricity, gas, water. If in doubt, seek professional advise.
-
Mark on the wall the centre of the duct hole.
-
Use this centre to mark a circle to suit the wall duct (115mm diameter).
If core drill equipment is available: -
a.Use as directed by core drill manufacturer.
If core drill equipment is not available:
4b. Drill a centre hole right through the wall. -
Cut the hole. Do not cut right through the wall. (The recommended method is to drill a series of holes, close together, around the edge of the cutting line and remove the brick between the holes with a chisel).
-
Go outside and cut a hole in the outer wall, repeating the process described above.
-
Cut ducting to the correct length if required. The wall tube supplied is telescopic and can extend to 300mm maximum.
-
Fit the ducting. Ensure that the duct slopes down away from the fan to allow drainage of any incoming rain water to the outside.
-
Make good the hole. Allow the mortar to set before continuing the fan installation.
If installing in a window or panel
- Cut a hole, 125mm in diameter or if installing in a window, obtain a ready cut pane.
- The centre of the hole should be at least 110mm away from the edge of the panel or pane of glass.
If installing in a ventilation shaft
- Check there are no buried pipes or cables in the ventilation shaft. If in doubt, seek professional advise.
- Cut a hole 110mm in diameter, in the side of the shaft.
- If the shaft has cavity wall, use the wall tube to bridge the cavity.
- Fit ducting and condensation trap if necessary, positioning condensation trap as near to the fan as possible.
If installing in a ceiling
- Check there are no buried pipes or cables in the ceiling/joists etc. If in doubt, seek professional advise.
- Cut a hole 115mm diameter.
Preparing the fan for installation
Remove the front cover by pressing the release catches located on the sides of
the unit with a 3mm screwdriver, whilst pulling the front cover forward L
If installing in a window or panel less than 16mm thick, the fan spigot needs
to be cut back to the visible step 20mm away from the rear of the back plate.
- Remove the impeller by pulling it forward.
- Cut the spigot back to the step using a junior hacksaw, ensure that the motor shaft is not marked by the hacksaw.
- Remove any burrs from the edge of the spigot.
- Refit the impeller by locating it onto the shaft and pushing it on fully.
Mount the fan in the hole
If working above ground floor level, appropriate safety precautions must be
observed.
If installing in a wall, ceiling or vent Mark the position of the back plate B
- Hold the backplate so that the terminal block faces you in the top left hand corner and the lip points towards the hole.
- Carefully insert the lip into the wall duct/ceiling or vent shaft.
- Adjust the position of the back plate until it is level.
- Mark on the wall/ceiling or vent shaft the positions of the three fixing holes in the back plate.
- Remove the back plate from the ducting.
- Drill screw holes in these positions if necessary, and fit wall plugs if necessary.
Mount the back plate C
- Push the ribbed gasket (RG100) onto the lip of the back plate 1
- If installing in a ceiling or vent, push the larger diameter piece of the telescopic wall tube onto the ribbed gasket. Cut the tube to the required length first, if necessary.
- If wiring the fan from behind, remove knockout. Feed the mains cable through the cable entry hole in the back plate to the terminals D .
- If wiring from above, leave the cable free to be fitted into labyrinth.
- Insert the lip of the back plate into the wall duct/ceiling or vent shaft as before.
- Fasten the back plate to the wall/ceiling or vent shaft using appropriate fasteners. If using screws, do not overtighten the screws.
Mount the back draught shutter
- Peel the backing from the foam strip supplied and attach it around the outside of the lip on the back draught shutter.
- Go outside. Holding open the top and bottom vanes, insert the lip into the wall duct.
- Making sure that the back draught shutter is level, mark the positions of the two fixing holes in the top right hand and bottom left hand corners.
- Remove the back draught from the wall duct.
- Drill screw holes in these positions, and fit the remaining wall plugs.
- Holding open the top and bottom vanes, refit the back draught shutter and fasten it to the wall using the pointed and self-tapping screws. Do not over tighten screws.
- Make sure that the vanes open and shut freely.
If installing in window or panel
Sealing the hole E
1. If installing in a window or panel no more than 9mm thick, fit the white
rubber gasket around the edge of the hole. If installing in a panel or sealed
double glazing more than 9mm thick, a DXDG double glazing kit is required.
Follow the instructions supplied with the special kit.
Attach the back draught shutter to the spacer F
- Holding the top and bottom vanes, insert the back draught shutter 2 into the spacer 3 so that the fixing holes in the top right and bottom left hand corners match those on the spacer.
- Insert two of the flat ended self-tapping screws provided and fasten the back draught shutter to the spacer.
Mount the fan in the window G
- Someone else must hold the back draught shutter and spacer in position outside, with the spacer against the glass.
- Make sure that the two raised fixing holes in the spacer are horizontal and are positioned within the hole.
- From inside, hold the back plate so that the terminal block faces you in the top left hand corner and the lip points towards that hole.
- Align the holes in the back plate with those in the spacer.
- Insert two of the flat ended self-tapping screws provided in the fixing holes, and fasten the back plate to the spacer. Do not overtighten the screws.
Wire the electrical connections
Make sure the mains supply is isolated,
- Wire the fan as shown in H check the fan model to diagram, feeding the cable between the two raised pegs, if wiring from above, and through labyrinth to terminal block.
- Switch off the mains electrical supply and remove fuses
- Connect the cable from the isolating switch to the electrical supply wiring.
- For xed wiring circuits the protective fuse for the appliance must not exceed 5A.
VX100T only I
- To adjust the over-run period turn the control (T) clockwise to increase and anti-clockwise to decrease.
All fans
- If wiring from above cut out the cable entry slot marked on top of the front cover.
- Fit the front cover by aligning it square to the duct and pushing it onto the duct until the release catches snap into the slots on the front cover.
Using the fan
VX100 only
- Operate the fan using the switch. Repeat to switch off.
VX100P only
- Operate the fan by pulling and releasing the cord. Repeat to switch off.
VX100T only
- Operate the fan using the switch. When the switch is turned off, the fan continues to operate for the adjustable time delay.
Cleaning (recommended once a month)
A QUALIFIED ELECTRICIAN MUST CARRY OUT ALL CLEANING.
- Before cleaning, isolate the fan completely from the mains supply.
- Remove the front cover by pressing the release catches located on the sides at the unit with a 3mm screwdriver, whilst pulling the front cover forward L
- To clean the front cover, either wipe it with a damp, lint free cloth or wash it in warm soapy water. Thoroughly dry the front cover and refit.
- Do not immerse the fan in water or other liquids to clean any other parts of the fan.
- Never use strong solvents to clean the fan.
- Apart from cleaning, no other maintenance is required.
Warranty.
UK only:
Xpelair products deliver reliable service for normal, household use in
domestic settings. All Xpelair products are individually tested before leaving
the factory.
If you are a consumer and you experience a problem with your Xpelair product,
which is found to be defective due to faulty materials and workmanship within
the warranty period, This Xpelair warranty will cover repair or at the
discretion of Xpelair replacement with a functionally equivalent Xpelair
Product.
The Xpelair warranty period is Two calendar years from the date of purchase of
your Xpelair product, or the date of delivery of the product, if later. The
Xpelair warranty is conditional upon you providing the original purchase
receipt proof of purchase. Please therefore retain your receipt as proof of
purchase.
If you do experience a problem with your Xpelair product please call the
helpline on +44 (0)344 879 3588 or at the address below. We will need details
of your Xpelair product, and a description of the fault which has occurred.
Once we receive your information and proof of purchase we will contact you to
make the necessary arrangements.
Customers outside UK – See International below.
If your Xpelair product is not covered by this Xpelair warranty there may be a
charge to repair your product. However, we will contact you for an agreement
to any charges before any chargeable service is carried out.
What is not covered by an Xpelair warranty?
The Xpelair warranty does not cover any of the following:
Any fault or damage to your Xpelair product due to faulty materials or
workmanship occurring outside the Two year warranty Period.
Any fault or damage occurring to any pre-owned Xpelair product or to any other
equipment or property.
Accidental damage to your Xpelair product or damage to your Xpelair product
from external sources (for example, transit, weather, electrical outages or
power surges).
Fault or damage to your Xpelair product which is:
Not due to faulty materials or workmanship or which is due to circumstances
outside Xpelairs control.
Caused by use of your Xpelair product for anything other than normal domestic
household purposes in the country where it was purchased.
Caused by any misuse, abuse or neglect use of the Xpelair product, including
but not limited to any failure to use it in accordance with the Operating
Instructions supplied with the product.
Caused by any failure to assemble, install, clean and maintain your Xpelair
product in accordance with th Operating Instructions supplied with the product
unless this was carried out by Xpelair or its authorised dealers.
Caused by repairs or altercations to your Xpelair product not carried out by
Xpelair service personnel or its authorised dealer(s).
Caused by use of any consumables or spare parts for your Xpelair product which
are not Xpelair specified.
Terms and Conditions
The Xpelair warranty is valid for Xpelair from the date of purchase of your
Xpelair product from a recognised retailer in the country of purchase and use,
or the date of delivery of the product if later, always provided the original
receipt has been retained and is produced as proof of purchase.
You must provide to Xpelair or its authorised agents on request the original
receipt as proof of purchase and – if required by Xpelair – proof of delivery.
If you are unable to provide this documentation, you will be required to pay
for any repair work required.
Any repair work under the Xpelair warranty will be carried out by Xpelair or
its authorised dealer(s) and any parts that are replaced will become the
property of Xpelair. Any repairs performed under the Xpelair warranty will not
extend the warranty period.
Any replacement of your Xpelair product by Xpelair during the warranty period
will start the Two year warranty period afresh from the date of delivery of
the replacement Xpelair product to you.
The Xpelair warranty does not entitle you to recover of any indirect or
consequential loss or damage including but not limited to loss or damage to
any other property.
The Xpelair warranty is in addition to your statutory rights as a consumer and
your statutory rights are not affected by this Xpelair warranty.
Contact Xpelair
If you have any questions about what the Xpelair warranty covers and does not
cover or how to claim under Xpelair warranty, please contact us using the
information below.
Contact details
Glen Dimplex UK Ltd,
Millbrook House, Grange Drive, Hedge End, Southampton, S030 2DF
Telephone: +44 (0) 344 879 3588
Email:
customer.services@glendimplex.com
Web: www.xpelair.co.uk
Glen Dimplex Europe Limited,
Airport Road, Cloghran, Co. Dublin, K67 VEO8.
Telephone: +353 (0)1 8523400
Email: serviceireland@glendimplex.com
International
Warranty: Contact your local distributor or Xpelair direct for details.
Technical advice and service: Contact your local Xpelair distributor.
Xpelair: A brand of Glen Dimplex Heating and Ventilation
© Glen Dimplex. All rights reserved.
**** Material contained in this publication may not be reproduced in whole or
in part, without prior permission in writing of Glen Dimplex For electrical
products sold within the European Community. At the end of the electrical
products useful life it should not be disposed of with household waste. Please
recycle where facilities exist. Check with a Local Authority or retailer for
recycling advise in your country. Batteries should be disposed of or recycled
in accordance with WEEE Directive 2012/EU. Packaging should be recycled where
possible.
Part No: 567202609AM (Rev G)