Vertex Standard VX-2200 Mobile Two Way Radio Instruction Manual
- June 8, 2024
- Vertex Standard
Table of Contents
Vertex Standard VX-2200 Mobile Two Way Radio
Congratulations! You now have at your fingertips a valuable communications tool: a VERTEX STAN-DARD two-way radio! Rugged, reliable and easy to use, your VERTEX STANDARD radio will keep you in constant touch with your colleagues for years to come, with negligible maintenance downtime. Please take a few minutes to read this manual carefully. The information presented here will allow you to derive maximum performance from your radio, in case ques-tions arise later on. We’re glad you joined the VERTEX STANDARD team. Call on us anytime, because communications is our business. Let us help you get your message across.
NOTICE !
There are no owner-serviceable parts inside the transceiver. All service jobs
must be referred to an authorized VERTEX STANDARD Service Represen-tative.
Consult your Authorized VERTEX STANDARD Dealer for installa-tion of optional
accessories.
SAFETY/WARNING INFORMATION
WARNING – DO NOT operate the VX-2200 radio when any person(s) (by- standers) outside the vehicle are within the distances shown in the chart at the bottom of this section.
Safety Training information:
Antennas used for this transmitter must not exceed an antenna gain of 0 dBd.
The radio must be used in vehicle-mount configurations with a maximum op-
erating duty factor not exceeding 50 %, in typical Push-to-Talk
configurations. This radio is restricted to occupational use, work related
operations only where the radio operator must have the knowledge to control
the exposure condi-tions of its passengers and bystanders by maintaining the
minimum separa-tion distance shown below. Failure to observe these
restrictions will result in exceeding the FCC RF ex-posure limits.
Antenna Installation:
For rear deck trunk installation, the antenna must be located at least the
fol-lowing distance away from rear-seat passengers in order to comply with the
FCC RF exposure requirements. For roof top installations, the antenna must be
placed in the center of the roof.
Unsafe Radiation Distance
VHF Model | UHF Model |
---|---|
4.6 Feet (1.4 m) | 3.9 Feet (1.2 m) |
INTRODUCTION
The VX-2200 Series are full-featured FM transceivers designed for flexible
mobile and base station business communications in the VHF or UHF Land Mobile
bands. These transceiver are designed for reliable business communications in
a wide vari-ety of applications with a wide range of operating capability
provided by their lead-ing-edge design.
The 128-channel memories can each be programmed with a 8-character channel
name. Important channel frequency data is stored in EEPROM and flash memory on
the CPU, and is easily programmable by dealers using a personal computer and
the VER-TEX STANDARD Programming Cable and CE82 Software. The pages which
follow will detail the many advanced features provided on the VX-2200 Series
transceiver. After reading this manual, you may wish to consult with your
Network Administrator regarding precise details of the configuration of this
equipment for use in your application. For North American Users Regarding 406
MHz Guard Band The U.S. Coast Guard and National Oceanographic and Atmospheric
Admin-istration have requested the cooperation of the U.S. Federal
Communications Commission in preserving the integrity of the protected
frequency range 406.0 to 406.1 MHz, which is reserved for use by distress
beacons. Do not attempt to program this apparatus, under any circumstances,
for operation in the fre-quency range 406.0 – 406.1 MHz if the apparatus is to
be used in or near North America.
CONTROLS & CONNECTORS
Front Panel
Important! – All buttons located on the Front Panel are Programmable Function (PF) Buttons, configured according to your network requirements and programmed by your VERTEX STANDARD dealer. The instructions below describe a typically-configured radio.
-
VOL/PWR Knob
Turn this control clockwise to turn the radio on and to increase the volume. Turn it counterclockwise into the click-stop to turn the radio off. -
Microphone Jack
Connect the microphone plug to this jack. -
[P1] – [P4] Buttons (Programmable Function Buttons)
These buttons can be set up for special applications, such as High/Low power selection, Monitor, Talk-Around, etc., as determined by your network requirements and programmed by your VERTEX STANDARD dealer. -
[ ]/[ ] Buttons (Programmable Function Buttons)
In the factory default, pressing either button changes the current channel (and displayed channel number or name). Holding in either button for more than 1.5 second causes the radio to begin stepping (repeatedly) upward or downward through the channels -
LCD (Liquid Crystal Display)
The display includes a 8-character alpha-numeric section showing Channel name tags/identity information and error messages, and an upper icon row displaying feature status (see below). -
TX/BUSY Indicator
Indicates transceiver’s Transmit/Receive Status -
Steady Red : Transmitting in progress
-
Steady Green : Signaling Off
-
Blinking Green : Busy Channel/Squelch Off
Rear Panel
-
13.6V DC Cable Pigtail with Connector
The supplied DC power cable must be connected to this 2-pin connector. Use only the supplied fused cable, extended if necessary, for power connection. -
Antenna Socket
The 50-Ohm coaxial feedline to the antenna must be connected here, using a type-M (PL-259) plug. -
D-Sub 15-Pin Accessory Connector
External TX audio line input, PTT (Push To Talk), Squelch, and external RX audio line output signals may be obtained from this connector for use with accessories such as data transmission/reception modems, and external Channel control input etc. -
External Speaker Jack
An external loudspeaker may be connected to this 2-contact, 3.5-mm mini-phone jack.
Caution : Do not connect either wire of this line to ground, and be certain that the speaker has adequate capability to handle the audio output (12 W) from the radio.
BASIC OPERATION OF THE TRANSCEIVER
Important! – Before turning on the radio the first time, confirm that the power connections have been made correctly and that a proper antenna is connected to the antenna jack.
Switching Power ON/OFF
- Turn the VOL/PWR knob turn on the radio. The display will become illuminated.
- Press the [ ]/[ ] button to choose the desired operating channel. A channel name will appear on the display. If you want to select an operating channel from a different group, press the PF (Programmable Function) button which is programmedto the Group Up/Down feature to select the group you want before selecting the operating channel. See page 7 for more information on the Programmable Function keys.
Setting the Volume
Turn the VOL/PWR knob clockwise to increase the volume, and counterclockwise
to decrease it.
Transmitting
- To transmit, monitor the channel and make sure it is clear. THIS IS AN FCC REQUIRMENT!
- Press the PF button which is programmed to the Monitor feature to listen for channel activity.
- When receiving a call, transmit only after the incoming call ends. The radio cannot receive a call and transmit simultaneously.
- Press the PTT switch.
- If the channel is clear, the TX/BUSY indicator will glow red. The radio is now transmitting. While holding in the PTT switch, speak across the face of the microphone in a clear and normal voice. For best transmission, hold the microphone about 1-1/2 to 2 inches away from your mouth. Release the PTT switch to receive.
- If the Busy Channel Lockout feature has been programmed on a channel, the radio will not transmit when a carrier is present. Instead, the radio will generate a short beep three times and indicate “ ERROR ” on the display. Release the PTT switch and wait for the channel to be clear of activity.
- If CTCSS or Digital Coded Squelch (DCS) Lockout has been programmed on a channel, the radio can transmit only when there is no carrier being received or when the carrier being received includes the correct CTCSS tone or DCS code.
Automatic Time-Out Timer
If the selected channel has been programmed for automatic time-out, you must
limit the length of each transmission. While transmitting, a beep will sound
10 seconds before time-out. Another beep will sound just before the deadline;
the red “TX” indicator will disappear and transmission will cease soon
thereafter. To resume transmitting, you must release the PTT switch and wait
for the “penalty timer” to expire (if you press the PTT switch before this
timer expires, the timer restarts, and you will have to wait another “penalty”
period)
Key Lock
In order to prevent accidental frequency change or inadvertent transmission,
various aspects of the VX-2200’s keys may be locked out. To activate the
Locking feature, press and hold in the [P1] key while turning the radio on. To
disable the Locking feature, repeat this power-on procedure
ADVANCED OPERATION
Programmable Function (PF) Buttons
The VX-2200 Series includes six Programmable Function (PF) Buttons. The PF
button functions can be customized, via programming by your VERTEX STANDARD
dealer, to meet your communications/network requirements. Some features may
require the purchase and installation of optional internal accessories. The
possible PF button programming features are illustrated below, and these
functions are explained on the pages to follow. For further details, contact
your VERTEX STANDARD dealer. For future reference, check the box next to the
function that has been assigned to each PF button on your particular radio,
and keep it handy.
Function | PF Button ( PRESS KEY / PRESS AND HOLD KEY ) |
---|---|
P1 | P2 |
MONI | / |
SQL OFF | / |
SQL SET | / |
DIMMER | / |
Channel Up | / |
Channel Down | / |
Continuous Ch Up | —/ |
Continuous Ch Down | —/ |
Group Up | / |
Group Down | / |
SCAN | / |
SCAN SET | / |
Group SCAN | / |
Group SCAN SET | / |
DW (Dual Watch) | / |
Follow-Me SCAN | / |
Follow-Me DW | / |
LOW | / |
TA (Talk Around) | / |
TA SCAN | / |
Encryptionx | / |
Emergency | / |
RESET | / |
CALL 1 | / |
CALL 2 | / |
CALL 3 | / |
DTMF CODE SET | / |
Code Up | / |
Code Down | / |
Code SET | / |
Speed Dial | / |
Public Address | / |
EXT. ACC1 | / |
EXT. ACC2 | / |
Direct CH#1 | / |
Direct CH#2 | / |
AF Min Vr | / |
Lone Worker | / |
HA (Horn Alert) | / |
Key Lock | / |
SET | / |
Description of Operating Functions
MONITOR (MONI)
Press (or press and hold) the assigned programmable key to cancel CTCSS- and
DCS-controlled squelch; the TX/BUSY indicator will glow green
SQUELCH (SQL) OFF
Press (or press and hold) the assigned programmable key to open the SQL to
hear background noise (unmute the audio); the TX/BUSY indicator will blink
green.
SQUELCH (SQL) SET
You can manually adjust the squelch level using this function:
- Press (or press and hold) the assigned programmable key. A tone will sound, and the current squelch will level appears on the display.
- Press the [ ]/[ ] button to select the desired squelch level.
- Press this key again. A tone will sound, and the display will revert to the normal channel indication.
DIMMER
Press (or press and hold) the assigned programmable key to select the
brightness level of the display. Available selections are four levels.
CHANNEL UP/DOWN
Press (or press and hold) the assigned programmable key (generally the [ ]/[ ]
button) to select a different channel within the current group.
CC UP/DOWN (CONTINUOUS CH UP/DOWN)
Press and holding in the assigned programmable key causes the radio to begin
stepping (repeatedly) upward or downward through the channels.
GROUP UP/DOWN
Press (or press and hold) the assigned programmable key to select a different
group of channels
CHANNEL SCAN (SCAN)
The Scanning feature is used to monitor multiple channels programmed into the
transceiver. While scanning, the transceiver will check each channel for the
presence of a signal, and will stop on a channel if a signal is present.
To activate scanning:
-
Press (or press and hold) the assigned programmable key to activate scanning on the current group.
-
The scanner will search the programmed channels, looking for active ones; it will pause each time it finds a channel on which someone is speaking.
-
Press (or press and hold) the assigned programmable key again to disable scanning. Operation will revert to the programmed revert channel.
Note : Your dealer may have programmed your radio to stay on one of the following channels:- Current channel (“Talk Back”)
- “Last Busy” channel
- “Priority” channel
- “Scan Start” channel
SCAN SET
Press (or press and hold) the assigned programmable key to delete the Current
Memory channel from the Scanning. When you delete a Group or channel, “- SKIP
-” will appear on the LCD for one second after pressing the assigned
programmable key. To restore a particular channel to your scanning list, press
(or press and hold) the assigned programmable key again; “- STOP -” will
appear on the LCD for one second after pressing the assigned programmable key.
GROUP SCAN
The Scanning feature is used to monitor multiple channels programmed into the
transceiver. While scanning, the transceiver will check each channel of the
programmed group for the presence of the signal, and will stop on a channel if
a signal is present. Press (or press and hold) the assigned programmable key
to activate the scanning on the selected groups.
GROUP SCAN SET
You may wish to have the Scanner pass through more than one Group during the
scanning process (normally, scanning is performed within the current group
only). To include the current Group in the scanning loop, press (or press and
hold) the assigned programmable key. To remove a Group from Group Scan, press
(or press and hold) the assigned programmable key again.
DUAL WATCH (DW)
The Dual Watch feature is similar to the SCAN feature, except that only two
channels are monitored:
- The current operating channel; and
- The Priority channel
To activate Dual Watch:
- Press (or press and hold) the assigned programmable key.
- The scanner will search the two channels; it will pause each time it finds a channel on which someone is speaking.
To stop Dual Watch:
- Press (or press and hold) the assigned programmable key.
- Operation will revert to the “Dual Watch Start” channel
FOLLOW-ME SCAN
“Follow-Me” Scan feature checks a User-assigned Priority Channel regularly as
you scan the other channels. Thus, if only Channels 1, 3, and 5 (of the 8
available channels) are designated for “Scanning,” the user may nonetheless
assign Channel 2 as the “User-assigned” Priority Channel via the “Follow-Me”
feature. To activate “Follow-Me” scanning, first select the channel you want
to designate as the “User-Assigned Priority Channel” and press (or press and
hold)the assigned programmable key. Then press (or press and hold) the Channel
Up/Down key (generally the [ ]/[ ] button) to recall to the “Scanning Start”
channel which has been programmed by your dealer to activate the scanner. When
the scanner stops on an “Active” channel, the User-assigned Priority Channel
will automatically be checked every few seconds; if activity is found on the
User-assigned Priority Channel, the radio will switch between it and the
Dealer-Assigned Priority Channel, if any
FOLLOW-ME DUAL WATCH (DW)
To set up a “Dual Watch” frequency pair using the “Follow-Me” feature,
select a channel using the Channel Up/Down key (generally the [ ]/[ ] button).
Now press (or press and hold) the assigned programmable key; pressing the
assigned programmable key locks the current channel as the User-assigned
Priority Channel. Now press (or press and hold) the Channel Up/Down key to
select another channel (not the “Scanning Start” channel). Your radio will now
switch back-and-forth between the currently-selected channel and the User-
assigned Priority Channel. During “Follow-Me” scanning (after you have pressed
the key), you can set up the “Dual Watch” feature by pressing (or press and
holding) the Channel Up/Down key to another channel. The radio will then scan
back and forth between the original User-assigned Priority Channel and the
newly-selected channel. The Priority Channel you have assigned (before
pressing the key) will be retained in memory until you change it.
LOW POWER (LOW)
Press (or press and hold) the assigned programmable key to set the radio’s
transmitter to the “Low Power” mode. Press (or press and hold) the key again
to return to “High Power” operation when in difficult terrain. When the
radio’s transmitter is set to “Low Power” mode, the “ LOW ” icon will be
indicated on the display.
TALK AROUND (TA)
Press (or press and hold) the assigned programmable key to activate the Talk
Around feature when you are operating on duplex channel systems (separate
receive and transmit frequencies, utilizing a “repeater” station). The Talk
Around feature allows you to bypass the repeater station and talk directly to
a station that is nearby. This feature has no effect when you are operating on
“simplex” channels, where the receive and transmit frequencies are already the
same. When the “TA” function is activated, the “ ” icon will be indicated on
the display. Note that your dealer may have mode provision for “Talk Around”
channels by programming “repeater” and “Talk Around” frequencies on two
adjacent channels. If so, the key may be used for one of the other Pre-
Programmed Functions.
TA SCAN
The “TA SCAN” is one of “DW Scan” between Rx and Tx frequency. It works the Rx
channel as priority channel and the radio will always transmit on the Tx
Channel if the PTT is pressed in the TA SCAN mode. Press (or press and hold)
the assigned programmable key to activate/deactivate the TA SCAN feature.
ENCRYPTION (OPTION)
When the Voice Scrambler feature is enabled, press (or press and hold) the
assigned programmable key to toggle the voice encryption on and off. When the
Voice Scrambler feature is activated, the “ ” icon will be indicated on the
display.
EMERGENCY
The VX-2200 series include an “Emergency” feature which may be useful if you
have someone monitoring on the same frequency as your transceiver’s channel.
Press (or press and hold) the assigned programmable key to initiate an
emergency call. For further details contact your VERTEX STANDARD dealer.
RESET
Press (or press and hold) the assigned programmable key to reset the RFC
(Ready for Communication) condition, or to reset the keypad entry condition.
CALL 1 TO CALL 3
Press (or press and hold) the assigned programmable key to send a 2-Tone or
5-Tone sequential burst which is pre-defined.
DTMF CODE SET
Press (or press and hold) the assigned programmable key to start storing the
DTMF dialing sequence. After completion to enter all DTMF digits, you can
transmit the codes by pressing the PTT key.
CODE UP/DOWN
Press (or press and hold) the assigned programmable key to select a 2-Tone or
5- Tone encode code from pre-defined encode list.
CODE SET
Press (or press and hold) the assigned programmable key to change the
5-Tone encodeing digit. To change the tones, select the desired digit using
the [P1]/[P2] keys, then change the number using the [ ]/[ ] keys.
SPEED DIAL
Your Dealer may have pre-programmed Auto-Dial telephone number memories into
your radio. To dial a number, press (or press and hold) the assigned
programmable key, then press the microphone’s key corresponding to the Auto-
Dial memory number list provided by your Dealer if the keypad microphone is
using, or press the PTT key if the normal (without keypad) microphone is
using. The DTMF tones sent during the dialing sequence will be heard in the
speaker.
PUBLIC ADDRESS
Press (or press and hold) the assigned programmable key to use the transceiver
as a PA amplifier. When you enable this function, a tone sounds and “PUBLIC A”
will appear on the display. The public address can be used even while scanning
and receiving a call.
EXT. ACC1
Press (or press and hold) the assigned programmable key to toggle output port
on “1” “on” and “off.”
EXT. ACC2
Press (or press and hold) the assigned programmable key to toggle output port
on “2” “on” and “off.”
DIRECT CH#1/CH#2
Press (or press and hold) the assigned programmable key to recall the Dealer
preprogrammed channel directly.
AF MIN VR
Press (or press and hold) the assigned programmable key to reduce the audio
output to the (lower) level programmed by your Dealer.
LONE WORKER
Press (or press and hold) the assigned programmable key to toggle the Lone
Worker feature “On” and “Off.” The Lone Worker feature is designed to emit an
alarm for 30 seconds when the Lone Worker Timer (programmed by your Dealer)
has expired. If the user does not reset the timer by pressing the PTT switch,
the radio switches to the Emergency mode. To revive the radio from the
Emergency mode, just press (or press and hold) the programmable key which is
assigned the Emergency feature or turn off the radio.
HA (HORN ALERT)
Press (or press and hold) the assigned programmable key to turn the Horn Alert
function “ON” or “OFF.” If you receive a call from the base station with
2-Tone, 5- Tone or DTMF signaling, horn alert will be activated and your
vehicles horn will sound. When you turn the Horn Alert “ON,” a tone will sound
and the “HORN ALT” will appear on the display.
KEY LOCK
Press (or press and hold) the assigned programmable key to lock the various
aspects of the VX-2200’s keys. The precise lockout configuration must be
programmed by your VERTEX STANDARD dealer.
SET
Press the assigned programmable key to activate the “User Set” (Menu) Mode
ARTS (Auto Range Transpond System)
This system is designed to inform you when you and another ARTS-equipped
station are within communication range. During ARTS operation, when the radio
receives an incoming ARTS signal, a short beep will sound, and “IN SVC” (“In
Service”) will be displayed on the LCD for 2 seconds. If you move out of range
for more than two minutes, your radio senses that no signal has been received;
a short triple-beep will sound, and “OUT SVC” (“Out of Service”) will be
displayed on the LCD for 2 seconds. If you subsequently move back into
communication range, as soon as the other station transmits, a short beep will
sound and “In” will be displayed again on the LCD for 2 seconds.
DTMF Paging System
(Requires the optional FVP-25 Encryption/DTMF Pager Unit) This system
allows paging and selective calling, using DTMF tone sequences. When your
radio is paged by a station bearing a tone sequence which matches yours, your
radio’s squelch will open and the alert will sound. The three-digit code of
the station which paged you will be displayed on your radio’s LCD.
USER SET MODE
The VX-2200 Series includes a “User Set” (Menu) Mode which allows the user to define or configure various settings, such as Squelch, Display contrast, etc. To activate the “User Set” (Menu) Mode:
- Press the programmable key assigned to the “SET” function.
- Select the User Set Mode item you wish to change using the [P1]/[P2] keys, then use the [ ]/[ ] keys to adjust the setting of the selected item.
- Press the [P1] or [P2] key to store the new configuration.
- Press the programmable key assigned to the “SET” function to exit to normal operation.
DISPLAY | DESCRIPTION |
---|---|
SQL | Sets the Squelch level. |
BEEP | Enables/Disables the Key Beeper. |
BELL | Enables/Disables the Bell function. |
(alert tone activated by incoming subaudible CTCSS/DCS tone)
LIGHTING| Enables/Disables the BUSY/TX LED.
GROUP| Select the desired Channel Group.
SCAN| Engages/Disengages Scanning (same as the programmable [SCAN] key).
DW| Engages/Disengages Dual Watch (same as the programmable [DW] key).
TA| Engages/Disengages Talk Around (same as the programmable [TA] key).
ENCRYPTX| Enables/Disables the disabling the Encryption Unit temporarily.
ENB: Enables the disabling the Encryption Unit.
DIS: Disables the disabling the Encryption Unit.
AF MINVR| Sets the minimum Audio Volume level.
BEEP VR| Sets the Beep Volume level.
CONTRAST| Sets the LCD Contrast level.
DIMMER| Sets the brightness of the LCD backlighting.
Requires optional unit
OPTIONAL ACCESSORIES
- MH-67A8J Standard Microphone
- MH-25A8J Standard Microphone
- MH-64A8J 16 Keypad Microphone
- MD-11A8J Desktop Microphone
- MLS-100 External Speaker (12 W Peak Power)
- MLS-200 External Speaker (15 W Peak Power)
- FP-1023A External Power Supply (13.8 VDC 23 A)
- FVP-25 DTMF Paging/Voice Inversion Type Encryption Unit
- FVP-36 Voice Inversion Type Encryption Unit
- FVP-35 High Level Encryption Unit
- VME-100 ANI Encode Unit (MDC-1200®/GE-STAR® ANI ENCODE)
- VT60FS VX-trunk Unit (w/ Encryption)
- VT60F VX-trunk Unit
- LF-1 Line Filter
- VPL-1 Programming Kit (Computer to PC)
- CE82 PC Programming Software
- FIF-10A USB Programming Interface (Required the Microsoft® Windows® 2000 or Windows® XP)
- CT-104A Connection Cable for FIF-10A
Availability of accessories may vary; some accessories are supplied standard per local requirements, others may be unavailable in some regions. Check with your VERTEX STANDARD Dealer for changes to this list. Changes or modifications to this device not expressly approved by Vertex Standard could void the user’s authorization to operate this device.
Copyright 2006
VERTEX STANDARD CO., LTD. All rights reserved. No portion of this manual may
be reproduced without the permission of VERTEX STANDARD CO., LTD.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>