Specifications
- AIO – CU/DU/RU 3GPP Standard RAT Mode Platform SU-MIMO
- Modulation: DL: 4 layers, UL: 2 layers (4T2R); DL: QPSK/16QAM/64QAM/256QAM, UL: QPSK/16QAM/64QAM
- Interface: Copper(RJ45) x1, Optical (SFP+) x1
- Capacity: 64 active UEs
- Throughput: DL 1.2 Gbps (7DS2U); UL: 400 Mbps (DSUU)
- Duplex mode: TDD (7D1S2U, DSUU, SUDS)
- Frequency band: N48 100MHz
- Bandwidth: Maximum 4T4R, Internal
- Antenna: 250mW (24dBm) per channel
- Dimensions: 310 x 265 x 95 mm
- Weight: 5 kg
- Power supply: 12V DC adaptor (85~264VAC input)
Product Usage Instructions
Installation and Setup
Follow the provided Wall Mount Bracket Installation Manual for mounting the device securely on Masonry Walls or Cement Walls.
Connection
Connect the device using the provided interfaces:
- SFP+ Fiber for Datalink
- RJ45 for management port/Debug use
- 12V Adapter Connector for power supply
Application
The device is primarily used for small-cell 5G applications. It
connects to a 5GC Server to provide networking for 5G signals.
Maintenance
Regularly check the device for any dust accumulation and ensure proper ventilation to prevent overheating.
FAQ
- Q: What should I do if the device is not powering on?
- A : Check the power supply connection and ensure that the input voltage is within the specified range (85~264VAC).
- Q : How can I troubleshoot connectivity issues?
- A : Verify the cable connections, reset the device, and check for any configuration errors in the network settings.
Connect Your Talent
Overview
Introduction
A small Cell (Cedar) is an Integrated small Cell, and it includes CU/DU/RU.
Specification
AIO – CU/DU/RU
3GPP Standard| R15
RAT Mode| 5G SA, Option 2
Platform| NXP LX2160A + NXP LA123X
SU- MIMO| DL: 4 layers, UL: 2 layers (4T2R);
Modulation| DL: QPSK/16QAM/64QAM/256QAM,
UL: QPSK/16QAM/64QAM
Interface| 10Gbps Copper(RJ45) x1, Optical (SFP+) x1
Capacity| 64 active UEs
Throughput| DL 1.2 Gbps (7DS2U); UL: 400 Mbps (DSUU)
Duplex mode| TDD (7D1S2U, DSUU, DDDSUDDSUU)
Frequency band| N48
Bandwidth| 100MHz Maximum
Antenna| 4T4R, Internal
Max. transmit power| 250mW (24dBm) per channel
Dimensions| 310 x 265 x 95 mm
Weight| 5 kg
Power supply| 12V DC adaptor (85~264VAC input)
Application Interface (HW/Ant/SW)
ME Mechanical Specification
Configuration
Packing Mechanical Specification
Packing Structure
-
Step 1
Wrapped the device with foam, then placed it well into the EPE. -
Step 2
Put the accessories in the right place. -
Step 3
Put the EPE with the device in the carton first. -
Step 4
Then put the EPE with accessories on the top of the carton. -
Step 5
H-sealing.
Application Block diagram
The device is used for small cell 5G application as below as
Application Description
- Use small cell to connect 5GC Server and provide networking for 5G signal
- Small Cell is adapter 4T4R structure and RF power is 250mW/per path.
- RJ451 or SFP+1 for Data link;
- RJ45*1 for management port/Debug use.
Wall Mount Bracket Installation Manual
Materials
Masonry Walls or Cement Walls
6- Drill holes in the wall.
- Step. 2 Insert plastic anchors into the holes in the wall.
- Step. 3 Insert Screw-B through Bracket-B into plastic anchors.
- Step. 4 Put the Bracket-A on the device and fixed by four screws.
Note: Assuming I/O ports facing down.
- Step. 5 Put Bracket-A into bracket-B two slide rails from top to bottom
FCC STATEMENT
Legal Information
Warning Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference
- This device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user‘s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna
- Increase the separation between the equipment and the receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device has been tested and meets applicable limits for Radio Frequency (RF) exposure. This equipment should be installed and operated with a minimum distance 20cm between the radio & your body.
RF Exposure Information
This device has been tested and meets applicable limits for Radio Frequency (RF) exposure. This equipment should be installed and operated to ensure a minimum of 20 cm spacing to any person at all times.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>