Xpelair C4SR Simply Silent 100mm Contour Fan Instruction Manual

June 9, 2024
Xpelair

Simply Silent™ 100mm Contour Fan
Installation and Maintenance Instructions
C4SR (078339) Standard

C4TSR (078346) Timer
C4PSR (078353) Pull Cord
C4HTSR (078360) Humidistat, Timer
Instruction Manual
Xpelair C4SR Simply Silent 100mm Contour Fan
-

C4SR Simply Silent 100mm Contour Fan

  • Do read the entire instruction leaflet before commencing installation.
  • Do install each fan with a means for disconnection in all poles in the fixed wiring.
  • Do make sure the mains supply is switched off before attempting to make electrical connections or carry out any maintenance or cleaning.

Please leave this leaflet with the fan for the benefit of the user.

This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance.
Cleaning and maintenance of the appliance shall not be made by children.

This appliance is intended for connection to fixed wiring.
Check that the electrical rating shown on each fan matches the mains supply.
THE APPLIANCE IS DOUBLE INSULATED AND DOES NOT REQUIRE AN EARTH CONNECTION.
All installations must be supervised by a qualified electrician. Installations and wiring must conform to current IEE Regulations (UK), local or appropriate regulations (other countries).
**** All Xpelair Simply Silent™ Contour AC fans have the following features:

  • Two speed extraction (Selectable at installation)
  • Built-in back draught shutter
  • Replaceable Baffle. Fans are supplied with the Square Baffle fitted. This can be exchanged with the spare Round Baffle supplied within the pack.
C4SR – Operate the fan using an on/off switch (not supplied).
C4PSR – Operate the fan using an integral pull-cord.
C4TSR* – Built-in timer operates fan for a preset delay from 30 seconds to 30

minutes.
C4HTSR*| – Operates when triggered automatically by the integral humidity sensor, or by using an external on/off switch (not supplied).
In automatic mode: the built-in timer automatically operates the fan for a pre-set delay time from 30 seconds to 30 minutes once humidity drops below the pre-set Relative Humidity (RH) value.
External operation: When switched off using the external on/off switch the fan continues to run for the preset delay from 30 seconds to 30 minutes.

* Factory settings: Timer 15 minutes, RH 75%

Xpelair C4SR Simply Silent 100mm Contour Fan - fig 1Xpelair C4SR Simply Silent 100mm Contour Fan - fig
2Xpelair C4SR Simply Silent 100mm Contour Fan -
fig 3

Where to locate the fan.

  • Locate it as high as possible.
  • At least 110mm from the edges of the mounting surface to the centre of the hole.
  • As far away as possible from and opposite to the main source of air replacement to ensure airflow acrossthe room (e.g. opposite the internal doorway).
  • Near the source of steam or odours.
  • Not where ambient temperatures are likely to exceed 50°C.
  • If installed in a kitchen fans must not be mounted immediately above a cooker hob, or eye level grill.
  • If installing in a room containing a fuel burning device which has a non-balanced flue, it is the installer’s responsibility to ensure that there is enough replacement air to prevent fumes being drawn down the flue when the fan is operating up to maximum extract. Refer to Building Regulations for specific requirements.
  • Exhaust air must not be discharged into a flue used for exhausting of fumes from appliances supplied with energy other than electric. Requirements of all authorities concerned must be observed for exhaust air discharge and intake flow rates.
  • Not suitable for use in possible chemical corrosive atmospheres.

What the installer will need.

  • 3mm electrician’s screwdriver and No.1 or 2 Pozidrive screwdrivers.

Installation

If wall mounting the fan, you will also need:

  • A 100mm diameter prepared hole.
  • An appropriate external Wall Grille and Ø100mm wall sleeve duct. Kit Ref 91232AW.

If ceiling mounting the fan, you will also need:

  • A 100mm diameter prepared hole.
  • Appropriate ancillaries for termination. These items are available from Xpelair:
  1. 3m flexible ducting Ref: 89663AA. If the duct passes through a cold space use insulated duct ref: 89847AA.
  2. Soffit Grille Ref: 89742AW
  3. XCT100 – Condensation Trap. Ref: 89749AA. Fitted immediately above the fan, this prevents water ingress due to condensation forming in the duct above the fan and running down.

If surface mount wiring the fan, you will also need:

  • Miniature PVC trunking 16mm wide x 8mm deep to house the cable to the fan.

Installing the isolating switch and cables.

**** A means for disconnection in all poles must be incorporated in the fixed wiring in accordance with wiring regulations

  • If metal switch boxes are used, earthing regulations must be followed.
  • The cross-sectional area of the supply cord used should be ranged from 1-1.5mm².
  • C4SR / C4PSR – 2 core, C4TSR / C4HTSR – 3 core.
  • C4TSR / C4HTSR. A wall or ceiling On/Off switch (with indicator light) is recommended
  1. Check that the electrical rating shown inside the back-plate matches your mains supply.

  2. Check there are no buried pipes or cables e.g. electricity, gas, water behind the switch location (in the wall or above the ceiling). If in doubt, seek professional advice.

  3. Isolate the mains supply.

  4. Lay in the cable from the isolating switch to the fan location via the on/off switch (if required). This must be housed in miniature PVC trunking.

  5. Lay in the cable from the isolating switch to the point of connection to the mains supply.
    Warning: Do not make any connections to the electrical supply at this stage.

  6. Install the isolating switch and on/off switch (if required).

  7. Make all connections within the isolating switch and the on/off switch (if required).

Wet Rooms: On/Off switch must be situated so that it cannot be touched by persons making use of the bath or shower.

For Australia Only – C4SR / C4PSR
Connection to the supply can be made by a flexible 2-core cable complete with 3 pin plug for insertion into an approved 10A GPO or directly wired through an approved 10A wall mounted surface switch with at least 3mm clearance between contacts.
For Australia Only –C4TSR / C4HTSR
These models are permanently connected to the supply and operation is controlled by a remote switch. They should be directly wired to the supply through an approved 10A wall mounted surface switch with at least 3mm clearance between contacts.

Preparing the Fan for installation.

  1. Remove the front cover/baffle assembly by depressing the latch on the underside of the cover and pulling off the front cover / baffle from the bottom (See Figure C).
    If working above ground floor level, safety precautions must be observed.
    Mark the position of the back-plate

  2. Hold the back-plate so that the level line marked on it is orientated horizontally.

  3. Carefully insert the fan tube into the wall duct.

  4. Mark on the wall the positions of the fixing holes in the back-plate.

  5. Remove the back plate from the ducting.

  6. Drill screw holes in these positions if necessary, and fit wall plugs and screws as required. The fan may also be fixed to a wall tube using the clamping brackets. See 9 below.
    If installing in a ceiling, appropriate termination ancillaries are required. Follow instructions provided.
    Mount the back-plate.

  7. Feed the mains cable through the cable entry hole in the back plate to the terminals. If surface mount wiring ‘break out’ the side wall in the duct flange for cable entry (See Figure E)

  8. Insert the fan tube of the back-plate into the wall duct/ceiling as before.

  9. Fasten the back-plate to the wall/ceiling using appropriate fasteners. See figure A.

  10. If using screws, do not over tighten. The fan may also be fixed to a wall tube using the clamping brackets. Tighten the screws until the fan is firmly secured to the tube – see figure B.
    Wire the electrical connections.

  11. Make sure the mains supply is isolated. Switch off the mains electrical supply and remove fuses.

  12. Feed the cable to the terminal block. Wire the fan as shown in Figure H using the diagram appropriate to the fan model.

  13. Connect the cable from the isolating switch to the electrical supply wiring.

Xpelair C4SR Simply Silent 100mm Contour Fan - fig 4

Fan Settings.

SPEED SETTING
The fans are factory set to low speed, but have two speed settings for different applications. Select either high or low speed by connecting the jumper between the centre and high or low speed pin on the jumper (see Figure F)

C4TSR Only.

  • To adjust the over-run period turn the control (T) clockwise to increase and anti-clockwise to decrease – see Figure D.

C4HTSR Only – see figures D and F.

  • The pre-set humidity operation is factory set at approximately 75% Relative Humidity (RH), but can be adjusted between 65% and 85% RH by control H.
  • The over-run timer is factory set at 15 minutes but can be adjusted from 30 seconds to 30 minutes by control T.
  • Turn the controls clockwise to increase RH or time and anti-clockwise to decrease.

Using the fan.
C4SR Only

  • Operate the fan using the on/off switch (not supplied). Repeat to switch off.

C4PSR Only

  • Operate the fan by pulling and releasing the cord. Repeat to switch off.

C4TSR Only

  • Operate the fan using an on/off switch (not supplied). When the switch is turned off, the fan continues to operate for the set time delay. To adjust the over-run period, turn the control “T” clockwise to increase and anti-clockwise to decrease – see Figure F.

C4HTSR Only.

  • Automatic mode – The fan automatically adjusts to slow changes in natural humidity levels without operating the fan. If the humidity levels increase at a rate slower than 5% RH in 5 minutes, up to the pre-set humidity level, the fan will not be triggered by humidity. This is to prevent nuisance triggering of the fan. If humidity levels increase  quicker than 5% RH in 5 minutes the fan will operate. When relative humidity drops the fan continues to operate for the adjustable time delay.
  • External operation – Use the external on/off switch. When the fan is switched off, the fan continues to operate for the adjustable time delay then goes into automatic mode.

All Fans
Re-fit the front cover/baffle assembly by hooking in the top first, and then swing the cover down to clip into place.
If surface mount wiring, ‘break out’ the thin wall section in the front cover prior to re-fitting (see figure E). The miniature PVC trunking must then be sealed against the front cover to prevent any water ingress.
Replacing Square Baffle with Round Baffle (Figs. G1 and G2)
Ensure fan is isolated from supply before performing this action.

  1. Remove Square Baffle/Cone assembly from Fan Front Cover by twisting anti-clockwise until all three support legs are released from clips.
  2. Fit Round Baffle/Cone assembly by aligning clips on baffle with legs on Front Cover and rotating Baffle Clockwise until all three clips engage and are retained on Front Cover.

Cleaning (recommended once a month).

  1. Before cleaning, isolate the fan completely from the mains supply.
  2. Remove the front cover/baffle assembly by depressing the latch on the underside of the cover and pulling off the front cover / baffle from the bottom.
  3. To clean the front cover/baffle assembly, either wipe it with a damp, lint free cloth or wash it with warm soapy water. Thoroughly dry the front cover and refit.
  4. Do not immerse the fan in water or other liquids to clean any other parts of the fan.
  5. Do not use strong detergents, solvents or chemical cleaners
  6. Allow fan to dry thoroughly before use.
  7. Apart from cleaning, no other maintenance is required.

Important
**** For electrical products sold within the European Community. At the end of the electrical products useful life it should not be disposed of with household waste. Please recycle where facilities exist. Check with a Local Authority or retailer for recycling advice in your country. Batteries should be disposed of or recycled in accordance with WEEE Directive 2012/19/EU. Packaging should be recycled where possible.

Warranty

What does an Xpelair Warranty cover?
Xpelair products deliver reliable service for normal, household use in domestic settings. All Xpelair products are individually tested before leaving the factory.
If you are a consumer and you experience a problem with your Xpelair product, which is found to be defective due to faulty materials or workmanship within the Warranty Period, this Xpelair Warranty will cover repair or – at the discretion of Xpelair – replacement with a functionally equivalent Xpelair product.
The Xpelair Warranty Period is two calendar years from the date of purchase of your Xpelair product, or the date of delivery of the product, if later. The Xpelair Warranty is conditional upon you providing the original purchase receipt as proof of purchase. Please therefore retain your receipt as proof of purchase.
If you do experience a problem with your Xpelair product please call the Helpline on +44 [0]344 879 3588 or at the address below.
We will need details of your Xpelair product, and a description of the fault which has occurred. Once we receive your information and proof of purchase we will contact you to make the necessary arrangements.
Customers outside UK – see international below.
If your Xpelair product is not covered by this Xpelair Warranty there may be a charge to repair your product. However, we will contact you for agreement to any charges before any chargeable service is carried out.

What is not covered by an Xpelair Warranty?
The Xpelair Warranty does not cover any of the following:

  • Any fault or damage to your Xpelair product due to faulty materials or workmanship occurring outside the two year Warranty Period.

  • Any fault or damage occurring to any pre-owned Xpelair product or to any other equipment or property.

  • Accidental damage to your Xpelair product or damage to your Xpelair product from external sources (for example, transit, weather, electrical outages or power surges).

  • Fault or damage to your Xpelair product which is:

  • Not due to faulty materials or workmanship or which is due to circumstances outside Xpelair’s control.

  • Caused by use of your Xpelair product for anything other than normal domestic household purposes in the country where it was purchased.

  • Caused by any misuse, abuse or negligent use of the Xpelair product, including but not limited to any failure to use it in accordance with the Operating
    Instructions supplied with the product.

  • Caused by any failure to assemble, install, clean and maintain your Xpelair product in accordance with the Operating Instructions supplied with the product unless this was carried out by Xpelair or its authorised dealers.

  • Caused by repairs or alterations to your Xpelair product not carried out by Xpelair service personnel or its authorised dealer(s).

  • Caused by use of any consumables or spare parts for your Xpelair product which are not Xpelair specified.

Terms and Conditions

  • The Xpelair Warranty is valid for Xpelair from the date of purchase of your Xpelair product from a recognised retailer in the country of purchase and use, or the date of delivery of the product if later, always provided the original receipt has been retained and is produced as proof of purchase.
  • You must provide to Xpelair or its authorised agents on request the original receipt as proof of purchase and – if required by Xpelair – proof of delivery. If you are unable to provide this documentation, you will be required to pay for any repair work required.
  • Any repair work under the Xpelair Warranty will be carried out by Xpelair or its authorised dealer(s) and any parts that are replaced will become the property of Xpelair. Any repairs performed under the Xpelair Warranty will not extend the Warranty Period.
  • Any replacement of your Xpelair product by Xpelair during the Warranty Period will start the two year Warranty Period afresh from the date of delivery of the replacement Xpelair product to you.
  • The Xpelair Warranty does not entitle you to recovery of any indirect or consequential loss or damage including but not limited to loss or damage to any other property.
  • The Xpelair Warranty is in addition to your statutory rights as a consumer and your statutory rights are not affected by this Xpelair Warranty.

Contact Xpelair
If you have any questions about what the Xpelair Warranty covers and does not cover or how to claim under the Xpelair Warranty, please contact us using the information below.
Contact details
Millbrook House, Grange Drive, Hedge End, Southampton, SO30 2DF
Telephone: +44 (0) 344 879 3588
Email: customer.services@glendimplex.com
www.xpelair.co.uk

International.

  • Guarantee: Contact your local distributor or Xpelair direct for details.
  • Technical Advice and Service: Contact your local Xpelair distributor.

Xpelair: A brand of the GDC Group Limited, trading as Glen Dimplex Heating & Ventilation
© Glen Dimplex. All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing of Glen Dimplex

Xpelair C4SR Simply Silent 100mm Contour Fan - fig 5 Part No: 08/100114/0 (Rev A)