SEALEY STW901 Torque Wrench Micrometer Style 3pc Set Instruction Manual
- June 1, 2024
- SEALEY
Table of Contents
SEALEY STW901 Torque Wrench Micrometer Style 3pc Set
Product Information
Specifications
- Model: STW900SET
- Drive: 1/4, 3/8, 1/2
- Length: 245mm, 420mm, 520mm
- Range: 5-25Nm, 20-120Nm, 40-220Nm
Product Usage Instructions
Safety
Ensure all workshop safety rules, regulations, and conditions are complied with when using the torque wrench. Maintain the wrench in good condition and replace any damaged or worn parts with genuine parts only. The wrench is a precision tool, do not abuse it. Maintain correct balance and footing, ensure the floor is not slippery, and wear non-slip shoes. Keep children and unauthorized persons away from the working area. Do not use the wrench if damaged or thought to be faulty.
Introduction
This product is a SQ Drive Torque Wrench Micrometer Style – Calibrated Series model STW900SET manufactured by Sealey. It is designed to provide accurate torque measurements for various applications. Follow the instructions carefully for safe and effective use of the product.
Operation
Preparing to Set Torque
Release torque adjuster by sliding the collar backwards. Set torque as required and then lock in place by sliding the collar forwards.
Setting Torque Value
Follow the instructions provided in figure 1 and figure 2 for setting the torque value accurately.
Re-Certification
Parts support is available for this product. For any inquiries or support needs, please contact sales@sealey.co.uk or call 01284 757500.
Environment Protection
Recycle unwanted materials instead of disposing of them as waste. When the product becomes unserviceable, drain any fluids into approved containers and dispose of the product and fluids according to local regulations.
Warranty and Support
This product comes with a lifetime guarantee. Proof of purchase is required for any warranty claims. Contact Sealey Group for further assistance or information.
Register Your Purchase
Visit www.sealey.co.uk to register your purchase and stay updated on product improvements and notifications.
Frequently Asked Questions
Q: Can I use this torque wrench for heavy-duty applications?
A: The torque wrench is designed for a specific torque range as mentioned in the specifications section. Ensure you use it within the recommended limits for optimal performance and longevity.
Q: How often should I recalibrate this torque wrench?
A: It is recommended to recalibrate the torque wrench periodically to ensure accurate torque measurements. Refer to the manufacturer’s guidelines for specific recalibration intervals.
Q: What should I do if I encounter any issues with the torque wrench?
A: If you experience any problems or suspect a fault with the torque wrench, do not use it and contact a qualified service agent for inspection and potential repairs.
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
SAFETY
- Ensure all workshop safety rules, regulations, and conditions are complied with when using torque wrench.
- Maintain the wrench in good condition and replace any damaged or worn parts. Use genuine parts only. Non-authorised parts may be dangerous and will invalidate the warranty.
- The wrench is a precision tool, DO NOT abuse it.
- Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes.
- Keep children and unauthorised persons away from the working area.
WARNING! DO NOT use the wrench if damaged or thought to be faulty. (Contact Service Agent).
- DO NOT drop or throw the wrench.
- DO NOT use wrench unless you have been instructed in its use by a qualified person.
- DO NOT use any cleaner which might affect the high pressure grease with which the wrench is packed.
- After use adjust to lowest torque setting (but not below),clean and store in a safe, dry, childproof location.
INTRODUCTION
Flip reverse Chrome Vanadium steel ratchet head with smooth action mechanism. Scales graduated in both Nm and lb.ft. Calibration tolerance in accordance with BS EN ISO 6789-1:2017. Wrenches are individually tested to standards with ±4% accuracy and each wrench is issued with an individually numbered test certificate. Aluminium knurled handles for comfort and control. Supplied in an EVA tray.
SPECIFICATION
Model | STW901 | STW903 | STW904 |
---|---|---|---|
Drive | 1/4” | 3/8” | 1/2” |
Length | 245mm | 420mm | 520mm |
Range | 5-25Nm | 20-120Nm | 40-220Nm |
OPERATION
PREPARING TO SET TORQUE (fig.1)
- Release torque adjuster by sliding the collar backwards. Set torque (see 4.2) and then lock in place by sliding the collar forwards.
SETTING TORQUE VALUE (fig.1, fig.2)
- With the adjuster unlocked (fig.1), rotate the handle to reach the main scale value i.e. 60 Nm (fig.2) aligned with collar value 0.
- To set the torque to more discrete values i.e. 52 Nm (fig.2) alig n main scale to 50 and then rotate collar value to 2 (fig.2).
- Once the torque value is set, slide the locking ring forward to lock adjuster in position.
- When tightening the nut/bolt you will feel and hear the wrench mechanism click when the set torque is reached. Immediately stop applying force to wrench to avoid overtightening nut/bolt. Wrench will reset ready for next application.
NOTE: If the wrench has not been used for some time, operate it a few times, at a low setting, to ensure all internal parts are coated in grease.
RE-CERTIFICATION
Unless otherwise stipulated, and to ensure continued accuracy of the torque tool, a period of 12 months, or 5,000 cycles (whichever occurs first), may be taken as default values for the interval between calibration checks. This calibration check should also be carried out if the torque tool has been subjected to an impact, has been misused, or the readings are suspect. Jack Sealey Ltd have up-to-date calibration checking equipment, certified to international standards, to carry out this service.
Parts support is available for this product. Please email sales@sealey.co.uk or telephone 01284 757500
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools,
accessories and packaging should be sorted, taken to a recycling centre and
disposed of in a manner which is compatible with the environment. When the
product becomes completely unserviceable and requires disposal, drain any
fluids (if applicable) into approved containers and dispose of the product and
fluids according to local regulations.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice. Important: No Liability is accepted for incorrect use of this product.
Warranty: Lifetime guarantee. Proof of which is required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500
sales@sealey.co.uk
www.sealey.co.uk
TORQUE TOOL CALIBRATION CERTIFICATE
Declaration of Conformance (in accordance with BS EN ISO 6789-1:2017)1
Notes:
- Testing is in compliance with International Standard procedures, with test equipment calibrated by a laboratory traceable to International Standards.
- Measurement error shall be less than ¼ of the maximum permissible relative deviation of the torque tool.
- The observed values fall within the maximum permissible deviation (tolerance). For tools with a flexible head, the result is valid only if the measuring axis is perpendicular to the axis of the tool.
- This Sealey Declaration of Conformance is issued at the time of manufacture and its validity is open ended until the torque tool is used for the first time. Unless otherwise stipulated, a period of 12 months, or 5,000 cycles, whichever occurs first, may be taken as default values for the interval between calibration checks. This period starts after first use of the torque tool. (BS EN ISO 6789-1:2017, clause 5.3 refers).
© Jack Sealey Limited
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>