Hank Scene Controller HNKESCN01 Manual

June 8, 2024
HANK

Hank

Scene Controller

SKU: HNKESCN01

Quickstart

This is a
secure
Wall Controller
for
Europe
.

To run this device please insert fresh *1 LIR2450** batteries.

Please make sure the internal battery is fully charged.

1. Insert the LIR2450 battery.
2. Set the Z-Wave network main controller into learning mode( see Z-Waave network controller operating manul).
3. Triple click the Z-button.
4. If the inclusion is successful, the LED will blink in blue less than for 5 seconds and then keep on for 15 seconds.

Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.

Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This
device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message ( two- way
communication
) and every mains powered node can act as a repeater for other nodes
( meshed network ) in case the receiver is not in direct wireless range of the
transmitter.

This device and every other certified Z-Wave device can be used together with any other
certified Z-Wave device regardless of brand and origin
as long as both are suited for the
same frequency range.

If a device supports secure communication it will communicate with other devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to maintain
backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer
to www.z-wave.info.

Product Description

The Scene Controller is a wireless, portable and rechargeable scene switch. It can control a Z-Wave device, such as smart plug, smart dimmer with a Z-Wave gateway. You can also activate a scene like sleep scene, movie scene and entertainment scene with it.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default
state.
Please make sure to reset the device into factory default. You can do this by
performing an Exclusion operation as described below in the manual. Every Z-Wave
controller is able to perform this operation however it is recommended to use the primary
controller of the previous network to make sure the very device is excluded properly
from this network.

Reset to factory default

This device also allows to be reset without any involvement of a Z-Wave controller. This
procedure should only be used when the primary controller is inoperable.

Pressing and holding the Z-button for 20 seconds. Release the button after 20 seconds, LED will keep in yellow for 3 seconds. Scene Controller will be reset to factory defaults if you short press the button within this 3 seconds.

Safety Warning for Batteries

The product contains batteries. Please remove the batteries when the device is not used.
Do not mix batteries of different charging level or different brands.

Installation

Open the cover, as the figure beows shows.

Insert your battery and close the cover, as the figure below shows.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs
to be added to an existing wireless network to communicate with the devices of this network.
This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network. This
controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is
then performed doing a special manual action right on the device.

Inclusion

Non-secure: Triple click the Z-button.

Secure: Pressing and holding the Z-button for 3 seconds.

Exclusion

Triple click the Z-button, if the exclusion is successful, LED will blink in orange for less than 5 seconds and then keep on for 3 seconds.

Product Usage

LOW BATTERY ALARM FUNCTION

If the battery level of the Scene Controller is less than 20%, the Scene Controller will sound 3 times” when the button is pressed.

COMMUNICATION FAILURE ALARM FUNCTION

The Scene Controller will sound one time when the communication between the Scene Controller” and any one of the controlled device is failed.

TESTING Z-WAVE NETWORK RANGE

Scene Controller’s LED indicator can signal its communication quality with the Z-Wave main” controller.

To start testing:

Press and hold the Z-button for 11 to 15 seconds, the LED will keep on in purple for 3 seconds, it” will enter testing mode if you short press the Z-button during these 3 seconds.”

Blink in green –Scene Controller establish a direct communication with the main controller, and” still under checking.

Keep green – The green light should last about 2 seconds, which means the direct communication” is stable.

Blink in orange –Scene Controller can communicate with the main controller in intermediate radio” transmit power level, and still under checking.

Keep orange – The communication quality is moderate.

Keep Red – The communication is failed.

BATTERY CHARGING

Scene Controller has an internal rechargeable battery that will run for half a year under the normal” use condition. If the battery level is less than 20%, this will activate the low battery level function,” this means you need to charge the battery.

The charger’s output should be a micro USB terminal with the specification of output DC 5V.” The LED nearby the micro USB port will keep on in red during the changing, and it will turn to green.

Communication to a Sleeping device (Wakeup)

This device is battery operated and turned into deep sleep state most of the time
to save battery life time. Communication with the device is limited. In order to
communicate with the device, a static controller C is needed in the network.
This controller will maintain a mailbox for the battery operated devices and store
commands that can not be received during deep sleep state. Without such a controller,
communication may become impossible and/or the battery life time is significantly
decreased.

This device will wakeup regularly and announce the wakeup
state by sending out a so called Wakeup Notification. The controller can then
empty the mailbox. Therefore, the device needs to be configured with the desired
wakeup interval and the node ID of the controller. If the device was included by
a static controller this controller will usually perform all necessary
configurations. The wakeup interval is a tradeoff between maximal battery
life time and the desired responses of the device. To wakeup the device please perform
the following action:

Pressing and holding Z-Button for 3 seconds. Led will turn to green, which means Scene Controller has been woken up.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association – one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device
controlling another device is called association. In order to control a different
device, the controlling device needs to maintain a list of devices that will receive
controlling commands. These lists are called association groups and they are always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’ Command.

Association Groups:

Group NumberMaximum NodesDescription

1| 5| Scene Controller will send Scene Controller sends the central scene notification command and battery report command to the associated nodes.
---|---|---
2| 5| Scene Controller will send Basic Set command to the associated nodes.
3| 5| Scene Controller will send switch multilevel set, the multilevel start level change and multilevel stop level change command to the associated nodes.

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock further
enhanced features.

IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56.
In case of a two byte value the same logic applies: Values greater than 32768 may
needed to be given as negative values too.

Parameter 254: Enable/disable the configuration command

Lock/unlock all configuration parameters.
Size: 1 Byte, Default Value: 0

SettingDescription

0 Unlock all configuration parameters.
1 Lock all configuration parameters

Parameter 255: Reset Scene Controller

Reset Scene Controller and remove from the Z-Wave network
Size: 4 Byte, Default Value: 0

SettingDescription

1431655765 Reset Scene Controller and remove from the Z-Wave network

Technical Data

Dimensions 0.0500000×0.0160000×0.0500000 mm
Weight 18.63 gr
Hardware Platform ZM5101
EAN 6925312929075
IP Class IP 20
Voltage 3V
Battery Type 1 * LIR2450
Device Type Wall Controller
Network Operation Portable Slave
Z-Wave Version 6.51.08
Certification ID ZC10-16085175
Z-Wave Product Id 0x0208.0x0200.0x0009
Frequency Europe – 868,4 Mhz
Maximum transmission power 5 mW

Supported Command Classes

  • Association Group Information
  • Association V2
  • Battery
  • Central Scene V2
  • Configuration
  • Device Reset Locally
  • Firmware Update Md V2
  • Manufacturer Specific V2
  • Powerlevel
  • Security
  • Version V2
  • Wake Up V2
  • Zwaveplus Info V2

Controlled Command Classes

  • Basic
  • Battery
  • Central Scene V2
  • Switch Multilevel V2

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network.
    Controllers are typically Gateways,Remote Controls or battery operated wall controllers.

  • Slave — is a Z-Wave device without capabilities to manage the network.
    Slaves can be sensors, actuators and even remote controls.

  • Primary Controller — is the central organizer of the network. It must be
    a controller. There can be only one primary controller in a Z-Wave network.

  • Inclusion — is the process of adding new Z-Wave devices into a network.

  • Exclusion — is the process of removing Z-Wave devices from the network.

  • Association — is a control relationship between a controlling device and
    a controlled device.

  • Wakeup Notification — is a special wireless message issued by a Z-Wave
    device to announces that is able to communicate.

  • Node Information Frame — is a special wireless message issued by a
    Z-Wave device to announce its capabilities and functions.

Read User Manual Online (PDF format)