Alecto BC-19 Digital Thermometer

PARTS OF DESCRIPTION

Parts Description

  1. temperature sensor
  2. display
  3. on/start/stop/memory/off button

temperature display

temperature display memory

battery empty

INTRODUCTION

This Alecto BC-19 thermometer is a digital thermometer developed to take your temperature as simply and accurately as possible. In order to get the most reliable results, these instructions must be followed accurately. For the most accurate temperature reading, we recommend using the thermometer rectally. Although the generally accepted ‘normal’ temperature is 37.0°C, body temperature can vary from 36.1°C to 37.2°C.

Fluctuations in temperature can be due to activities such as sports, smoking, eating and drinking, and also depend on the part of the body where the temperature is taken. When measured orally, the body temperature is generally 0.5°C lower than when measured rectally, while a temperature measured under the armpit is 1.0°C lower. Your temperature is lower in the morning than in the evening.

SPECIFICATIONS

  • Temperature range: 32.0°C – 42.9°C
  • Low temperature display:
  • temperature ≤ 32°C, display: Lo°C
  • High temperature display:
  • temperature ≥ 42,9°C, display: HI°C
  • Display resolution: 0.1°C
  • Accuracy: 35,5°C – 42.9°C: ± 0.1°C
  • ≤ 35,5°C ≥ 42°C: ± 0.2°C
  • Normal temperature ≤ 37.8°C: 10 beeps
  • Fever alarm ≥ 37.8°C: 10×3 beeps
  • Auto-OFF: 10 minutes ± 2 minutes
  • Battery: LR41 , 192 or SR41
  • Power consumption: 0,15 mW
  • Battery life: 2 years
  • Dimensions: 136 x 22 x 14,5mm
  • Weight: ±14 gr (batt incl.)
  • Conditions for use:
  • Temperature: 10°C – 35°C
  • Humidity: 25% – 80% RH
  • Storage conditions:
  • Temperature: -25°C – 55°C
  • Humidity: 25% -80% RH

MEASURING YOUR TEMPERATURE

  1. Press the ON/OFF key once to activate the thermometer. You will hear a beep.

  2. The display shows in succession: ‘188.8°C’ the last measured temperature ‘37,0’ (for internal calibration) ‘LO’ and flashing ‘°C’ (*)

  3. Place the thermometer in the chosen body part to measure your temperature.

  4. When you hear beeps, your temperature has been recorded. • if your body temperature is normal, you will hear 10 beeps • if your body temperature is above normal (≥37.8°C), you will hear
    10×3 beeps.

  5. Press the ON/OFF key to switch off the thermometer. (The thermometer will switch off automatically after approx. 10 minutes).
    *: If the room temperature is higher than 32.0°C, the room temperature will be shown instead of ‘Lo’

Measurement under the tongue:
Place the mometer under the tongue, as far back as possible to the left or right.

A temperature taken under the tongue is approx. 0.5°C lower than when taken rectally
Measurement

Measurement under the arm
Make sure the armpit is dry and place the thermometer under the arm. The sensor must touch the skin. Keep your arm crossed in front of your chest. A temperature taken under the tongue is approx. 1.0°C lower than when taken rectally.

Rectal measurement
Insert the thermometer sensor gently (maximum 1.25 cm).

BATTERY LOW

The battery is low when the symbol appears in the display. The battery cannot be replaced. Please replace the complete thermometer.

DISPOSAL OF THE DEVICE

At the end of the product lifecycle, you should not throw this product into the normal household garbage but bring the product to a collection point for the recycling of electrical and electronic equipments.

ADVICE AND WARNINGS

  • Keep the thermometer and battery out of the reach of children.
  • Do not talk or walk around while taking your temperature.
  • Store the thermometer in the special case.
  • Do not expose the thermometer to direct sunlight, dust or moisture.
  • Do not dismantle the thermometer

STORAGE AND CLEANING

Clean the thermometer before and after use, using a soft cloth and alcohol, or cold soapy water. The thermometer may be briefly immersed in water or alcohol (do not soak or sterilise). Store the thermometer in the special case.

CE

The declaration of conformity is available at:
http://DOC.hesdo.com/BC-19-DOC.pd

WARRANTY

For the Alecto BC-19 thermometer you have a warranty of 24 months from the date of purchase. During this period, we guarantee the free repair of defects caused by material and workmanship errors. All this subjected to the final assessment of the importer.

HOW TO HANDLE: If you notice any defect, first refer to the user’s manual. Please contact the supplier of this thermometer or contact customer service of Alecto via the Internet www. alecto.nl

THE WARRANTY BECOMES NULL AND VOID: In case of improper use, incorrect connections, leaking and/ or incorrectly installed batteries, use of unoriginal parts or accessories, negligence and in case of defects caused by moisture, fire, flooding, lightning and natural disasters. In case of unauthorised modifications and/or repairs performed by third parties. In case of incorrect transportation of the device without adequate packaging and when the device is not accompanied by this warranty card and proof of purchase.All further liability, especially concerning any consequential damages, is excluded.

Hangzhou Hua’an Medical &
Health Instruments Co.,Ltd,
Building 2, 1# Fuzhu Nan RD,
Wuchang Town, Yuhang District ,
Hangzhou, Zhejiang 310023
Model: DT-K101A

Shanghai International
Holding Corp. GmbH,
Eiffestrasse 80, 20537
Hamburg Germany

Imported by: Commaxx B.V.
Wiebachstraat 37, 6466 NG
Kerkrade, The Netherland

Service
Help
WWW.ALECTO.NL
SERVICE@ALECTO.NL

Commaxx B.V.
Wiebachstraat 37
6466 NG, Kerkrade
The Netherlands

Symbol
Symbol

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals