- Stiebel Eltron FTB 200 Electric Underfloor Heating
- Product Information
- Product Usage Instructions
- SPECIAL INFORMATION
- OPERATION
- Safety
- Settings
- Troubleshooting
- INSTALLATION
- Appliance description
- Preparation
- Covering the floor
- Installation
- Commissioning
- Commissioning
- Handover
- Specification
- Warranty card
- Test report
- Installation diagram
- Guarantee
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Stiebel Eltron FTB 200 Electric Underfloor Heating
Product Information
- Product Name: FTB 200
- Manufacturer: Stiebel-Eltron
- Website: www.stiebel-eltron.com
- Language: German (Deutsch)
Product Usage Instructions
-
General Notes:
- The user manual is available in multiple languages, including German.
- The manual contains information on operation, installation, maintenance, troubleshooting, and technical specifications.
-
Safety:
- The manual provides general safety instructions.
- Symbols are used to indicate different types of hazards and their severity.
- Signal words such as “GEFAHR” (danger), “WARNUNG” (warning), and “VORSICHT” (caution) are used to highlight the importance of safety instructions.
-
Operation:
- The section provides general information on operating the product.
- No specific usage instructions are provided in this section.
-
Cleaning, Care, and Maintenance:
- The product does not require any special maintenance.
- No cleaning instructions are provided.
-
Troubleshooting:
The section provides a table with common problems, their possible causes, and solutions. -
Installation:
- The section includes safety instructions and regulations that need to be followed during installation.
- The product should only be operated when fully installed with all safety devices.
-
Technical Specifications:
The section provides technical data and energy consumption information. -
Preparation:
- The section provides information on the installation location and conditions.
- It also includes information on the components included in the package.
-
Installation:
The section provides step-by-step instructions for installing the product, including installing an in-wall box and laying cold conductors. Please note that the text provided is in German (Deutsch). For a complete understanding of the user manual and accurate usage instructions, it is recommended to refer to the original manual in the desired language or contact Stiebel-Eltron customer service for assistance.
SPECIAL INFORMATION
-
The appliance may be used by children aged 8 and older and persons with reduced physical, sensory or mental capabilities or a lack of experience and know-how, provided that they are supervised or they have been instructed on how to use the appliance safely and have understood the potential risks. Children must never play with the appliance. Cleaning and user maintenance must not be carried out by children without supervision.
-
The connection to the power supply must
be in the form of a permanent connection. Ensure the appliance can be separated from the power supply by an isolator that disconnects all poles with at least 3 mm contact separation. -
To prevent hazards, the power cable must only be replaced (for example if damaged) by a qualified contractor authorized by the manufacturer, using an original spare part.
-
Fix the appliance in position as described in chapter “Installation / Preparations”.
OPERATION
General information
The chapters “Special information” and “Operation” are intended for appliance users and qualified contractors. The chapter “Installation” is intended for qualified contractors.
Notice
Read these instructions carefully before using the appliance and retain them
for future reference. Pass on these instructions to a new user if required.
Safety instructions
Structure of safety instructions
SIGNAL WORD Type of risk
Here, possible consequences are listed that may result from failure to observe
the safety instructions.
Symbols, type of risk
Signal words
Other symbols in this documentation
Notice
General information is identified by the adjacent symbol.
Read these texts carefully.
This symbol indicates that you have to do something. The action you need to take is described step by step.
Information on the appliance
Units of measurement
Notice
All measurements are given in mm unless stated otherwise.
Safety
Intended use
The heating mat is designed for electric underfloor heating in wet
environments, e.g. for wellness areas, tiled showers, loungers, benches or
whirlpool surrounds.
The appliance is intended for domestic use. It can be used safely by untrained
persons. The appliance can also be used in non-do-mestic environments, e.g. in
small businesses, as long as it is used in the same way.
Any other use beyond that described shall be deemed inappropriate. Observation
of these instructions and of the instructions for any accessories used is also
part of the correct use of this appliance.
General safety instructions
WARNING Injury
The appliance may be used by children over 8 years of age and persons with
reduced physical, sensory or mental capabilities or a lack of experience and
expertise, provided that they are supervised or they have been instructed on
how to use the appliance safely and have understood the potential risks.
Children must never play with the appliance. Cleaning and user maintenance
must not be carried out by children without supervision.
Property damage
Only operate the heating mat when fully installed and with all safety
equipment fitted.
Test mark
See type plate label, label on the warranty card or in the main junction box.
Settings
You can set the required floor temperature by means of an external floor
temperature controller.
The floor temperature which can be achieved depends on the floor structure and
the floor covering. Observe the information in the operating and installation
instructions for the floor temperature controller.
Floor temperature controller with a seven-day program
Energy saving operation is ensured by installing a floor temperature
controller with a seven-day program.
Using an individually definable seven-day program means that you can adapt the
temperatures to your personal requirements by specifying when the heating mat
will switch on and off. The self-learning, adaptive control unit automatically
determines the preheating time for timer mode. For economical operation,
adjust the time it switches off so that the appliance switches off
approximately half an hour before the end of use. Further information can be
found in the operating and installation instructions for the floor temperature
controller.
Cleaning, care and maintenance
The heating mat does not require any particular maintenance.
Troubleshooting
If you cannot remedy the fault, contact your qualified contractor. To
facilitate and speed up your enquiry, please provide the serial number from
the type plate (000000-0000-000000).
You will find the type plate on the warranty card in these instructions and in
the main junction box.
INSTALLATION
Safety
Only a qualified contractor should carry out installation, commissioning, maintenance and repair of the appliance.
General safety instructions
We guarantee trouble-free function and operational reliability only if
original accessories and spare parts intended for the appliance are used.
-
Property damage
Never switch on the heating mat when it is rolled up. -
Notice
Operation of the heating mat is only permissible in conjunction with an external floor temperature controller including floor temperature sensor.
Instructions, standards and regulations
-
Notice
Observe all applicable national and regional regulations and instructions. -
Notice
According to the Ecodesign Directive (the Commission’s companion guidelines to Regulation (EU) No. 2015/1188), external temperature control must be provided. Only use floor temperature controllers that meet the required correction factors.
Appliance description
- Heat conductor
- Floor temperature sensor
- Conduit (tube for installing the floor temperature sensor)
- Female connection for heating conductor/cold lead
- Cold lead (electrical power cable)
The heating mat is a surface heating element. The heating mat comprises a heat conductor which is sewn onto a self-adhesive mesh fabric.
The heating mat is glued directly to the screed or to levelling compound (e.g.
floating screed). The heat generated by the heating mat is thus transferred
directly to the floor.
The required floor temperature is set via an external floor temperature
controller. The floor temperature controller is equipped with a floor
temperature sensor. The floor temperature sensor must be installed at heating
level.
The heating mat is switched on or off according to the floor temperature set
on the floor temperature controller.
The floor temperature controller takes account of heat gain, e.g. due to
sunlight or lighting, and provides frost protection.
The floor temperature controller is self-monitoring. In the event of a power
failure, sensor break or sensor short-circuit, the heating automatically
switches off.
Standard delivery
- Heating mat
- Two type plate labels (warranty card / main junction box)
Warranty card / installation diagram
You must complete the warranty card and installation diagram fully. The
warranty is not valid without this proof.
The chapter “Preparation” contains information on completing the installation
diagram.
Preparation
Installation site / Installation conditions
-
Property damage
Do not lay the heating mat at temperatures below 5 °C. -
Notice
In new builds, allow the screed to cure for 4-6 weeks. Only install the heating mat once this period has ended.
Substrate
-
Property damage
The heating mat may only be laid on floors. Walls or ceilings may not be used as installation surfaces. -
Property damage
Never lay the heating mat on highly or normally flammable materials.
You may lay the heating mat on a variety of substrates, e.g. screed, hot mix asphalt or moisture-resistant chipboard. Observe the following information:
- Laying on hot mix asphalt: The substrate must be able to withstand temperatures of approx. 80 °C.
- Laying on wooden floors and chipboard: The heating mat may only be laid in combination with a separator mat. Suit-able insulation boards can also be laid to improve impact sound insulation.
- Very sandy screed surfaces must be coated with an adhesive dispersion.
Thermal insulation
Appropriate floor insulation between the unfinished floor and the heating mat
is essential to minimise heat losses to the floor. Please ensure that the
thermal insulation complies with the latest standards.
Bathrooms and shower rooms
The heating mat must not be laid in areas where sanitary equipment such as
baths, showers, freestanding WCs, etc. are to be installed.
Floor coverings
The heating mat is only suitable for use with tiles. Other floor coverings,
e.g. carpet, PVC or cork, must not be used.
-
Property damage
Only use floor coverings which are suitable for underfloor heating systems.
Note that floor coverings have different thermal conductivity values according to their type and the thickness of the material. -
Notice
According to the Energy Saving Ordinance (EnEV), the thermal resistance of the floor covering must not exceed 0.15 m2 kW. Observe the manufacturer’s instructions for the selected floor covering.
Covering the floor
Additional floor coverings, e.g. carpets, may lead to a temperature build-up in the floor itself.
- Do not use floor coverings which are more than 10 mm thick.
Minimum clearances
-
Property damage
Cupboards which cover the whole area must not be placed on heated areas. -
Property damage
The heating conductors on heating mats installed in parallel must not touch. -
Make sure that you observe a distance of at least 25 mm when installing heating mats in parallel.
-
When laying the heating mats, ensure that you maintain a minimum clearance of 60 mm to conductive parts of the building such as water lines.
Installation diagram
You must draw up an installation diagram before installing the heating mat.
See chapter “Sample installations” and “Minimum clearances” in this respect.
Draw the position of the heating mats, the floor temperature controller, the
floor temperature sensor and the cold lead on the installation diagram. Take
account of where cupboards that fully rest on the floor are located and where
sanitary ware is installed.
Sample installations
Test measurement 1
Before installation, please check the total resistance and insulation
resistance of the heating mats in their delivered condition.
Notice
The warranty is not valid without proof of this measurement.
- Measure the total resistance and insulation resistance of the heating mat.
- Check whether the measured values are in the permissible measuring range (see chapter “Specification / Data table”).
- Enter the actual values on the warranty card.
Preparing the substrate
- Make sure that the substrate is clean, dry, solid and free from dirt and grease.
- Make sure that no sharp edges or pointed objects are protruding from the floor. These could damage the heat conductor.
- If the substrate is not level, carry out levelling operations so as to avoid cavities beneath the heating conductor.
- Note that the heating mat may only be laid on wooden floors or chipboard in combination with an additional separator mat.
Installation
Installing the flush box
Property damage
In bathrooms and wet rooms, the flush box must only be installed outside
safety zone 2. The floor temperature controller is installed in a flush box.
Two conduits for the cold lead and the floor temperature sensor must be
inserted from the flush box down to the floor.
- Power cable (NYM 3×1.5 mm2)
- Flush box
- Conduit for floor temperature sensor
- Floor temperature sensor
- Conduit for cold lead
- Choose an appropriate position for the floor temperature controller. Install the flush box at this position.
- Install an additional flush box if you would like to connect more heating mats in parallel.
- Always install an additional flush box if the cold lead or the floor temperature sensor lead is too short.
Installing floor temperature sensors
- The floor temperature sensor must be installed in a conduit (ø 12 mm).
- The floor temperature sensor must be positioned directly below the heating mat and approx. 100 mm from the edge of the heating mat.
- The floor temperature sensor must be positioned exactly halfway between two heat conductors.
- The floor temperature sensor lead must not cross or touch the heat conductor.
- Choose an appropriate position for installing the conduit.
- Chisel out a groove in the screed using appropriate tools. Lay the conduit with the inserted sensor well.
- Insert the floor temperature sensor into the conduit.
Installing the cold lead
Property damage
The cold lead must be installed in a separate conduit. The cold lead and the
floor temperature sensor lead must not be installed in the same conduit.
- Install an additional conduit (ø 12 mm). Insert the cold lead into the conduit.
- Make sure that the female connection for the heat conductor/cold lead is not subjected to a tensile load.
Laying the heating mat
-
Property damage
Do not cut, squash or kink the heating conductor on the heating mat.
Ensure that heat conductors do not cross over one another. -
Notice
You may shorten and extend the cold lead as long as you do not change its cross-section. -
Property damage
Do not lay the heating mat across expansion joints or through/beneath insulating material. -
Property damage
You must not lay heating mats below cupboards that rest fully on the floor. -
Property damage
- Do not use nails or other metal objects to attach the heating mat to the floor.
- Only stand on the heating mat if absolutely necessary. Take any necessary protective measures to avoid mechanical damage (e.g. shoes with rubber soles).
-
Property damage
Do not use penetrating fixing materials in the vicinity of the heating mat, e.g. screws and rawl plugs for door stoppers. -
Property damage
There is an adhesive surface on the underside of the heating mat. The protective foil on the adhesive surface must be removed for laying the heating mat.
Unroll the heating mat with the self-adhesive side facing down, in accordance with the installation plan. Remove the protective foil on the adhesive surface little by little as you proceed. At the same time, press the heating mat onto the substrate.
For a change of direction, cut the heating mat backing fabric with scissors at the turning point. Make sure that you don’t accidentally damage or cut through the heat conductor with the scissors. The heat conductor is sewn onto the backing fabric.
Property damage
The smallest permissible bending radius is six times the diameter of the
heating conductor.
- Carefully bend the heating conductor at the cutting point.
- Observe minimum clearances (see chapter “Preparation /Minimum clearances”).
- Make sure that the floor temperature sensor is positioned centrally between two heat conductors and that the floor temperature sensor lead does not cross or touch the heat conductor.
- Make sure that heating mats do not overlap. Overlapping heating mats may lead to malfunctions.
- Make sure that the backing fabric is laid out without any creases.
- Press the heating mat firmly onto the floor.
Test measurement 2
After laying the heating mat, check the total resistance and insulation
resistance of the heating mat to rule out the possibility of damage to the
heating mat.
Notice
The warranty is not valid without proof of this measurement.
- Measure the total resistance and insulation resistance of the heating mats.
- Check whether the measured values are in the permissible measuring range (see chapter “Specification / Data table”).
- Enter the actual values on the warranty card.
- Replace the damaged heating mat if the measured values deviate from the permissible range.
Laying the floor covering
-
Property damage
Only use tile adhesive and levelling compound which are suitable for underfloor heating systems and which can withstand constant temperatures of at least 80 °C. -
Property damage
When applying tile adhesive and levelling compound, please observe the manufacturer’s instructions concerning drying time and other manufacturer’s information. -
Notice
You must wait at least 3 days, depending on the humidity levels within the building, before starting to lay the floor covering.
- Substrate with thermal insulation
- Heating mat with heating conductor
- Tile adhesive
- Floor covering
Select an appropriate tile adhesive or levelling compound, as applicable.
Seal the conduits so that tile adhesive cannot get into the conduits.
Apply the tile adhesive and levelling compound as applicable over the entire
surface. Take care not to damage the heating conductor.
Make sure that the heat conductor is fully enclosed in tile adhesive.
Make sure that no air bubbles form under the heating mat. Air bubbles may lead
to higher temperatures.
Lay the tiles in accordance with the manufacturer’s instructions.
Test measurement 3
After laying the floor covering, check the total resistance and insulation
resistance of the heating mats to rule out the possibility of damage to the
heating mats.
Notice
The warranty is not valid without proof of this measurement.
- Measure the total resistance and insulation resistance of the heating mats.
- Check whether the measured values are in the permissible measuring range (see chapter “Specification / Data table”).
- Enter the actual values on the warranty card.
Commissioning
Electrical connection
-
WARNING Electrocution
Carry out all electrical connection and installation work in accordance with national and regional regulations. -
WARNING Electrocution
The connection to the power supply must be in the form of a permanent connection.- Isolate the appliance from the power supply using an isolator with at least 3 mm omnipolar contact separation. Use mains isolators, fuses/MCBs, contractors, etc. for this purpose.
- Install an RCD with a nominal earth leakage current of ≦ 30 mA.
-
Property damage
The heating conductor must not be connected to the power supply. Only connect the cold lead to the power supply. -
Property damage
Observe the type plate. The specified voltage must match the mains power supply. -
Property damage
Make sure that the total connected load of the connected heating mats does not exceed the maximum breaking capacity of the floor temperature controller. -
Notice
Electrical connection work must only be carried out by a qualified contractor and in accordance with these instructions.
Basic wiring diagram
(e.g. for RTF floor temperature controller)
The basic wiring diagram below is provided for clarification purposes. The
floor temperature controller wiring diagram is the only applicable wiring
diagram (see operating and installation instructions for the floor temperature
controller).
Notice
Observe the operating and installation instructions for the floor temperature
controller when making the electrical connection.
- Connect the floor temperature sensor to the floor temperature controller.
- Connect the earth conductor to the earth connection (PE).
- Connect the heating mats to the floor temperature controller via the cold lead.
- Connect the floor temperature controller to the power supply.
- Check whether the earth conductor is connected correctly.
Connecting additional heating mats
-
Property damage
If you lay several heating mats in one room, the heating mats may only be connected in parallel to the mains power supply. -
Make sure that the total current does not exceed the maximum switching current and breaking capacity of the floor temperature controller. Information can be found in the operating and installation instructions for the floor temperature controller.
Commissioning
Initial start-up
Notice
Final commissioning can take place no sooner than 5 days after completion of
the floor. After laying the heating mat and applying tile adhesive or
levelling compound, you must wait at least 2 days before switching on the
heating mat for the first time. Switch on the heating mat for periods of max.
30 minutes over several days once this initial drying phase has been
completed. This ensures that the tile adhesive and levelling compound cure
slowly.
Commissioning report
- Make sure that you have completed the warranty card and the installation diagram correctly. Observe the following information:
- The installation diagram must show the exact position and number of the heating mats, the position of the flush boxes, cold leads and floor temperature sensor.
- Measured values from all three test measurements must be entered on the warranty card.
- Enter the measured total resistance and insulation resistance on both type plate labels.
- Attach the type plate label for the warranty card to the specific position on this card.
- Attach the type plate label for the main junction box in a highly visible location on this box.
Handover
- Explain the functions of the appliance to the user.
- Make users aware of potential dangers.
- Hand over these operating and installation instructions to the user.
- Hand over the completed warranty card and the installation diagram to the user.
- Inform the user that these documents must be stored care-fully and always be available in order to be able to trace the layout of the heating mat system in the future.
Specification
Energy consumption data
The product data complies with EU regulations relating to the Directive on the
ecodesign of energy related products (ErP).
Product information on electric individual room heaters to regulation (EU)
2015/1188
Data table
Warranty card
Test report
This guarantee is only valid if the warranty card is completed fully. The insulation resistance must be > 1 MΩ.
Installation diagram
Please create an accurate drawing of the room, the installed heating mats and the floor temperature sensor.
Guarantee
The guarantee conditions of our German companies do not apply to appliances
acquired outside of Germany. In countries where our subsidiaries sell our
products a guarantee can only be issued by those subsidiaries. Such guarantee
is only grant-ed if the subsidiary has issued its own terms of guarantee. No
other guarantee will be granted.
We shall not provide any guarantee for appliances acquired in countries where
we have no subsidiary to sell our products. This will not affect warranties
issued by any importers.
Environment and recycling
We would ask you to help protect the environment. After use, dispose of the
various materials in accordance with national regulations.
Deutschland
STIEBEL ELTRON GmbH & Co. KG
Dr.-Stiebel-Straße 33 | 37603 Holzminden
Tel. 05531 702-0
Fax 05531 702-480
info@stiebel-eltron.de
www.stiebel-eltron.de
Australia
STIEBEL ELTRON Australia Pty. Ltd.
294 Salmon Street | Port Melbourne VIC 3207
Tel. 03 9645-1833 | Fax 03 9644-5091
info@stiebel-eltron.com.au
www.stiebel-eltron.com.au
Austria
STIEBEL ELTRON Ges.m.b.H. Gewerbegebiet Neubau-Nord Margaritenstraße 4 A |
4063 Hörsching
Tel. 07221 74600-0 | Fax 07221 74600-42
info@stiebel-eltron.at
www.stiebel-eltron.at
Belgium
STIEBEL ELTRON bvba/sprl’t Hofveld 6 – D1 | 1702 Groot-Bijgaarden Tel. 02
42322-22 | Fax 02 42322-12
info@stiebel-eltron.be
www.stiebel-eltron.be
China
STIEBEL ELTRON (Tianjin) Electric Appliance Co., Ltd.
Plant C3, XEDA International Industry City Xiqing Economic Development Area
300385 Tianjin
Tel. 022 8396 2077 | Fax 022 8396 2075
info@stiebeleltron.cn
www.stiebeleltron.cn
Czech Republic
STIEBEL ELTRON spol. s r.o.
Dopraváků 749/3 | 184 00 Praha 8
Tel. 251116-111 | Fax 235512-122
info@stiebel-eltron.cz
www.stiebel-eltron.cz
Finland
STIEBEL ELTRON OY
Kapinakuja 1 | 04600 Mäntsälä
Tel. 020 720-9988
info@stiebel-eltron.fi
www.stiebel-eltron.fi
France
STIEBEL ELTRON SAS
7-9, rue des Selliers
B.P 85107 | 57073 Metz-Cédex 3
Tel. 0387 7438-88 | Fax 0387 7468-26
info@stiebel-eltron.fr