INOR ICON-X Transmitter Configuration Kit Instruction Manual

June 1, 2024
INOR

INOR ICON-X Transmitter Configuration Kit Instruction Manual

ICON-X

INOR TRANSMITTERS Supplementary Instructions

Accessories for Inor transmitters
Including the Ex-approved USB-interface ICON-X

Transmitter configuration kit

© INOR 04/2024 – 4006932901 – AD ICON-X ConSoft R02 en

CONFIGURATION KIT

General safety notes

CAUTION!
The USB interface ICON-X is an Ex-approved product that is intended to be used for all type of  transmitters when in safe areas.

General information

The configuration kit includes all necessary software and hardware for configuration of the  temperature transmitters from a PC´s USB port.

Configuration starts from the main program ConSoft. ConSoft will identify the connected  transmitter and open the necessary configuration software.

ICON-X configuration kit consists of:

  • USB interface ICON-X
  • USB cable (connection between PC and USB interface)
  • Adapter cables (connection between USB interface and transmitter)

The configuration kit is compatible with Windows XP (SP3), Windows Vista, Windows 7, Windows  8, Windows 8.1 and Windows 10.

DANGER!
ICON-X is the Ex-approved connection between a PC USB interface and an INOR Ex-approved  transmitter. It may be used with non-Ex approved Inor transmitter as well. The ICON-X must not  be used in hazardous area. Consult the user instruction and Ex-certificate of the used  transmitter regarding the possibility to configure “online” if the input of the transmitter is connected to hazardous area.

DANGER!
ICON-X contains no reparable parts. Repairing or fixing the circuit or replacing components may  impact the intrinsic safety.

CAUTION!
Only one transmitter may be connected at a time.

Certifications
EU directive compliance

The USB interface, used with the provided cables, is CE-marked and complies with the  statutory requirements of the relevant EU directives / UK regulations. For more information  refer to the Declaration of Conformity, which can be found in the download area of the  manufacturer’s website.

For other cables than the provided and with cable length ≥ 3 m / 9.8 ft. other requirements are  valid and are not covered by this product.

Ex approvals
ATEX KIWA 16ATEX0011X II (1) G [Ex ia Ga] IIC
IECEx IECEx KIWA 16.0005X [Ex ia Ga] IIC
USA FM18US0117X AIS CL I, Div 1 and 2, GP A-D,

CL I, Zn 0, 1 and 2, [AEx/Ex ia Ga] IIC

Canada| FM18CA0056X

USA and Canada:

EX-approvals according to: FM 3600, ANSI/ISA 60079-0, CAN/CSA C22.2 No. 0, CAN/CSA C22.2 60079-0, FM 3610, ANSI/ISA 60079-11, CAN/CSA C22.2 60079-11

See also “Special conditions for safe use” in the Ex certificates in the download area of the  manufacturer’s website.

Scope of delivery

Scope of delivery

Figure 1-1: Scope of delivery

➀ USB communication cable (connection between PC and USB interface)

➁ USB interface

➂ Mini USB to Mini USB adapter (USB interface to transmitter)

➃ Mini USB to four pole rectangular connector (USB Interface to transmitter)

➄ Mini USB to 3.5 mm tele plug connector (USB Interface to transmitter)

➅ Mini USB to three pole rectangular connector (USB Interface to transmitter)

Nameplate

Nameplate

➀ PN = Part number

SN = Serial number (yyww = year and week of manufacturing)

PO = Batch number

Technical data

Operating conditions

Ambient temperature 0…+50°C / +32…+122°F
Storage temperature -20…+70°C / -4…+158°F
Humidity (non-condensing) 0…90% RH

Installation

Installation For detailed information, refer to chapter “Installation”.
Dimensions USB interface Length: 114 mm / 4.49″; width: 36 mm / 1.42″ ;

heigth:  26 mm / 1.02″

Electrical connection

Power supply PC’s USB port; 5 VDC; 74 mA max.
Galvanic isolation 1500 VAC
Input (PC to USB interface) USB cable type A to type B
Output (USB interface to transmitter) Changeable adapter cables

System requirements

Windows Windows XP (SP3), Vista, 7, 8, 8.1 or 10
Display resolution Minimum 800×600
Free hard disk space 185 MB
PC Port 1x USB 1.1 or higher port type A

Ex parameters
Comm.port (PC connection)| Um = Vmax : 250 V AC/DC
Output port (to transmitter)| Uo = Voc : 9.4 VDC
| Io = Isc : 96 mA
| Po : 680 mW

INSTALLATION

General safety notes

CAUTION!
The USB interface ICON-X is an Ex-approved product that is intended to be used for all type of  transmitters when in safe areas.

Safety Diagram

DANGER!
The transmitter’s communication port (USB connection) may only be connected to the certified  ICON-X interface. When the ICON-X is connected, the temperature transmitter shall be outside  of the hazardous area; a connected sensor may be located in the hazardous area.

Safety Diagram

➀ Hazardous Area

➁ Safe Area

➂ Temperature Sensor

➃ Temperature Transmitter

➄ ICON-X USB interface

➅ Ex-approved Power Supply/ Zener barrier

➆ PC

Installation of USB interface drivers

Before you can use the USB interface you must install the USB drivers on your PC. The setup file  includes drivers for the USB interface and can be installed manually when running the setup file.  The drivers can also be installed automatically by using Windows Update if the computer  supports this function.

For detailed information refer to section “Installation guide for ConSoft and USB-Interface  drivers”.

All software, USB drivers and installation guides can also be downloaded from the website.

Installation of configuration software ConSoft

All necessary software for configuration can be downloaded from the website of the  manufacturer.

For detailed information refer to section “Installation guide for ConSoft and USB-Interface  drivers”.

All software, USB drivers and installation guides can also be downloaded from the website.

Description of USB interface ICON-X

The USB interface ICON-Xis powered from the PC´s USB port. There are three LED indicators on  the USB interface: “USB”, “PC” and “DEV”. They are indicators to make the understanding of the  communication between PC and transmitter easier. Their functions are described below:

  • “USB” LED indicates data transfer. It lights during data transfer, otherwise it is off.
  • “PC” LED indicates connection between configuration program and PC. It is green only during reading or writing to transmitter.
  • “DEV” LED indicates the transmitter connection status. If it’s green, the connected transmitter is detected by the USB interface. Flashing green indicates that the USB interface is waiting for a new transmitter from the same product family, e.g. changing to a new device. When it´s red no transmitter is detected by the USB interface and any sort of transmitter can be connected to the USB interface.

CAUTION!
The installation guide must be read prior to installation.

Installation guide for ConSoft and USB-Interface drivers

Locate the executable setup file “ConSoftSetup”. Double click on the file to start the installation  process and follow the instructions on screen.

Troubleshooting
Error message Action

Error message “USB Interface is not installed. The  program will not work.” displayed when starting  ConSoft.| Install drivers for the USB interface.
Error message “USB Interface:s hardware and/or  software should be updated.” appears in ConSoft.| Contact us for update of your USB interface.
Error message “Unable to install because a newer  version of this product is already installed.” is  displayed during installation of ConSoft.| A newer version of ConSoft is already installed on  the computer. If you still want to install the older  version, uninstall ConSoft through “Control Panel – Add or Remove Programs”.

Disassembling and recycling of Transmitter configuration kit ICON-X

This section describes (in short) the instructions of handling and disassembling the device when  it’s reached EOL (end of life) or is disposed of after usage. The information given is sufficient to  gather the most important parts of the device (by the end-user) which can be used for recycling.

Content of USB configuration kit ICON-X

Figure 2-1

Figure 2-1:

Item No Item Name Weight  (g) Weight  (lb)
1 USB communication cable (connection between PC and USB interface  ICON-X)
42 0,09
2 USB Interface ICON-X 63 0,14
3 Mini USB to Mini USB adapter (USB interface ICON-X to transmitter) 17

0,04
4| Mini USB to four pole rectangular connector (USB interface ICON-X to transmitter)| 23| 0,05
5| Mini USB to 3.5 mm tele plug connector (USB interface ICON-X to transmitter)| 19| 0,04
6| Mini USB to three pole rectangular connector (USB interface ICON-X to transmitter)| 24| 0,05
7| Case polypropylene| 300| 0,66
8| Foam cushioning PU| 20| 0,04
Total| | 506| 1,12

Table 2-1: USB configuration kit ICON-X
Item 1 and 3 – 6; sorted as electrical waste
Item 2; sorted according to chapter 2.9
Item 7 and 8; sorted as plastic.

Disassembling and recycling of USB Interface ICON-X DANGER!

DANGER!
The device MUST be disconnected from mains power before disassembling.

Wear personal protective equipment. Make sure you use a steady workplace/bench to do the  disassembly actions.

CAUTION!
Before disassembling the device, make sure you have the proper tools needed:

  • Torx Screwdriver T9
  • Philips head Screwdriver #1

Item 2 (Table 2-1) USB Interface ICON-X consists of

Item No Item Name Weight  (g) Weight  (lb)
1 Label, upper side polyester 0 0
2 Label, bottom side polyethylene 0 0
3 General purpose ABS plastic package box (UL94-HB) 38 0,08
4 PCB Glass fiber reinforced Epoxy 10,6×2,9 cmm2 22 0,05
5 Cover Screws threaded, 2 pieces (4×3/4 self-tapping oval head 19,1 mm) 2

0
6| Sealing washer, 2 pieces| 0| 0
7| PC Board Screws, 2 pieces (4×1/4 self-tapping oval head 6,4 mm)| 0| 0
Total| | 63| 0,14

Table 2-2: USB configuration interface ICON-X

Figure 2-2

Figure 2-2: Disassembled USB interface ICON-X

USB Interface ICON-X may be separated into smaller parts.

Items are numbered according to the Table 2-2.

  • Disassembling USB Interface ICON-X
  1. Disconnect connection to the PC (if any connected).
  2. Disconnect temperature transmitter (if any connected).
  3. Remove the labels (polyester and polyethylene) sorted as plastic.
  4. By unscrewing of the two threaded screws (item 5) from the bottom cover of the housing, upper  part of Item 3(in Table 2) can be separated from bottom part.
  5. Lift up front and rear panel of the item 3. They are sorted as plastic.
  6. By unscrewing of the two threaded screws(item 7) on the PCB(item 4) separate the bottom cov er of the housing – Item 3 and PCB(item 4).
  7. Items 1, 2 and 3 are sorted as plastic.
  8. Item 4 sorted as electronic waste.
  9. Item 6(Sealing washer) sorted as ordinary waste.
  10. Item 5 and 7 are sorted as metal waste.
Installation and control drawing

Installation and control drawing

NOTES

Notes

Notes

Notes

Inor Process AB
PO Box 9125
SE-200 39 Malmö
Sweden
Phone: +46-(0)40-312 560
Fax: +46-(0)40-312 570
E-mail: [email protected]

Subsidiaries

Inor Transmitter Oy
Unikkotie 13
FI-01300 Vantaa
Finland
Phone: +358-(0)10-4217900
Fax: +358-(0)10-4217901
E-mail: [email protected]
Web: www.krohne-inor.fi

Inor Transmitter GmbH
Am See 24
D-47279 Duisburg
Germany
Phone: +49-(0)203 7382 762 0
Fax: +49-(0)203 7382 762 2
E-mail: [email protected]
Web: www.inor-gmbh.de

Inor North America
7 Dearborn Road
Peabody, MA 01960
United States
Phone: +1 978 826 6900
Fax: +1 978 535 1720
E-mail: [email protected]
Web: www.inor.com

The current list of all INOR contacts and addresses can be found at:
www.inor.com

© INOR 04/2024 – 4006932901 – AD ICON-X ConSoft R02 en

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

INOR User Manuals

Related Manuals