DELTA DOP-107WVCS HMI Touch Screen User Manual
- June 1, 2024
- Delta
Table of Contents
DOP-107WVCS
High Color ‧Widescreen‧
User-Friendly HMI Products
Delta Electronics Inc,
No.18, Xinglong Rd., Taoyuan City 33068, Taiwan
Instruction Sheet
Preface
Thank you for purchasing DOP-107WV. This instruction sheet provides information about DOP-107WV. Before using the product, please read through this manual carefully in order to ensure the correct use of the product. In addition, please place this manual safely for quick reference whenever is needed. Please follow the rules below if you have not finished reading this manual yet.
- Before operate the touch panel, please remove the film of HMI.
- Install the product in a clean and dry location free from corrosive and inflammable gases or liquids, indoor use only.
- Ensure that all wiring instructions and recommendations are followed.
- Ensure that HMI is correctly connected to the ground. The grounding method must comply with the national electrical standard (Please refer to NFPA 70: National Electrical Code, 2005 Ed.
- Do not modify the wiring or disassemble HMI interface when HMI is connected to the power.
- Do not touch the power supply during operation. Otherwise, it may cause electric shock.
- When HMI displays low power notification and requires battery changes, please contact local distributors or DELTA customer service center for the replacement. Do not change batteries by yourself.
- DOP-100 series can be used for industrial automation equipment. Please read through this manual carefully and install the product according to the instructions in order to avoid danger.
- Cleaning method: Please use dry cloth to clean the product.
- The product should be used at an altitude below 5000 m.
- If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
- For repairing and maintenance, please contact DELTA Electronics, Inc. Address: No.18, Xinglong Rd., Taoyuan City, Taiwan. TEL: +886-3-3626301.
If you have any enquiry during operation, please contact our local distributors or Delta sales representatives. The content of this instructionsheet may be revised without prior notice. Please consult our distributors or download the latest version at https://www.deltaww.com/zh- tw/index.
Communication Port Pin Assignment
DOP-107WVCS COM1
COM Port | Pin | MODE1 |
---|
RS-232
| 1|
2| RXD
3| TXD
4|
5| GND
6|
7| RTS
8| CTS
9|
DOP-107WVCS COM2
COM Port | Pin | MODE1 | MODE2 | MODE3 |
---|---|---|---|---|
COM2 | COM3 | COM2 | COM3 | COM2 |
RS-232 | RS-485 | RS-485 | RS-485 | RS-232 |
1 | D+ | |||
2 | RXD | |||
3 | TXD | |||
4 | D+ | D+ | ||
5 | GND | GND | GND | |
6 | D- | |||
7 | RTS | |||
8 | CTS | |||
9 | D- | D- |
Note 1: Blank means connection is not required.
Part names
DOP-107WVCS (Front View)
A | Touch Screen/Display |
---|
DOP-107WVCS (Rear View)
A | Power Input (24AWG wire min.) | B | COM2/ COM3 |
---|---|---|---|
C | COM1 | D | Network Port(LAN) |
E | USB Slave | F | USB Host |
Dimensions for Installation
DOP-107WVCS
Operation Temperature is -30ºC ~ +70ºC
Storage Temperature is -40ºC ~ +80ºC
Installation and Wiring
Installation Notes:
- Improper installation will result in malfunction and greatly reduce the life of the HMI. Be sure to follow the guidelines in this quick start when installing the HMI.
- In order to ensure the HMI being well ventilated, make sure that the ventilation holes are not obstructed and provide sufficient clearance for the HMI.
- To protect the panel, be sure to install a waterproof gasket into HMI.
- For use on a flat surface of a Type 4X enclosure or equivalent. If Enclosure with lower type rating will cause de-rating.
- The allowable thickness of the panel for mounting should be less than 5 mm (0.2 inches)。
Installation Method:
Step 1:
Put the waterproof gasket into HMI and then insert the HMI into the panel
cutout.
Step 2:
Place the fasteners into slots and tighten the screws till reaching the panel
cutouts.
Step 3:
Tighten the screws with torque less than 0.5N-M / 0.7N-M to avoiddamage to the
plastic case. DOP-107 Torque: 6.17 lb-inch (0.7N-M)
Step 4:
For heat dissipation, keep a minimum clearance of 60 mm (2.36 inches) and 45
mm (1.77 inches) respectively on the rear and bottom of the HMI.
Recommended wiring is as follows:
Type | Material | Wire Gauge (AWG) | Stripped length | Torque |
---|---|---|---|---|
Solid | Copper | 24 ~ 12 | 7 ~ 8 mm | 5 kg-cm (4.3 lb-in) |
Stranded | Copper | 24 ~ 12 | 7 ~ 8 mm | 5 kg-cm (4.3 lb-in) |
WARNING
Be sure to perform wiring by referring to the following figure (power supply
connector), wiring must be rated 75℃ min
Specifications
Model | DOP-107WVCS |
---|---|
LCD Module | Display Type |
Resolution | 800 x 480 pixels |
Backlight | LED Back Light (less than 20,000 hours half-life at 25oC) (Note 1) |
Display Size | 154.08 x 85.92 mm |
Brightness | 1000 cd/m² (Typ.) |
CPU | ARM Cortex-A8 (1GHz) |
Flash ROM | 1000 Mbytes |
RAM | 1000 Mbytes |
Touch Screen | 4-wire resistive touch screen |
10,000,000 operated
Buzzer| Multi-Tone Frequency (2 K ~ 4 K Hz)/80 dB
Ethernet Interface| 10/100 Mbps Auto sensing (with built-in isolated power circuit (Note 2))
USB| 1 USB Slave Ver 2.0
1 USB Host Ver 2.0
SD| N/A
Serial Communication Port| COM1| RS-232 (supports flow control) (Note 2))
COM2| RS-232 (supports flow control) / RS-485(Note 2))
COM3| RS-422 / RS-485(Note 2))
Perpetual Calendar| Built-in
Cooling Method| Natural cooling
Safety Approval| CE / UL (Please use shielding Ethernet cable and the magnetic ring with filter of 300 ohm/100 MHz)
Waterproof Level of Panel Display| IP 66/NEMA 4/Type 12/Type 4X (indoor and outdoor use)
Operation Voltage (Note2)| +24 VDC (-15% ~ +20%) (with built-in isolated power supply unit)
Supplied by Class 2 or SELV circuit (isolated from MAINS by double insulation)
Voltage Endurance| 500 VAC for 1 minute (between charging (DC24V terminal) and FG terminals)
Power Consumption (Note 2)| 8.4W (Max) (Note 3)
Backup Battery| 3V lithium battery CR2032 × 1
Backup Battery Life| About 3 years or more at 25oC but subjects to the temperature and the conditions during usage.
Operation Temperature| -30oC ~ +70oC
Storage Temperature| -40oC ~ +80oC
Operating Environment| 10% ~ 90% RH [0 ~ 40oC], 10% ~ 55% RH [41 ~ 50oC], 10% ~ 20% RH [51 ~ 70oC]; Pollution degree: 1
Storage Environment| 10%~95%RH【0~40 oC】, 10%~55%RH【41~50 oC】, 10%~20%RH【51~80 oC】
Vibration Resistance| Conforms to IEC61131-2; Continuous: 5 Hz ~ 8.3 Hz 3.5 mm, 8.3 Hz ~ 150 Hz 1 G
Shock Resistance| Conforms to IEC60068-2-27: 11 ms, 15 G Peak , X, Y, Z direction for 6 times
Dimension (W) x (H) x (D) mm| 196 x 136 x 39
Dimension for Installation (W) x (H) mm| 186.8 x 126.8
Weight| Approx. 560 g
Note:
-
The half-life of backlight is defined as original luminance being reduced by 50% when the maximum driving current is supplied to HMI. The life of LED backlight shown here is an estimated value under 25ºC normal temperature and humidity conditions.
-
The withstand voltage of the isolated power circuit is 1500 V peak for 1 minute.
-
Power consumption of HMI is the power consumed when not connecting to any peripheral devices. To ensure normal operation of HMI, the recommended power supply is: power consumption x 1.5 ~ 2.
-
Isolated power supply is recommended.
-
DOPSoft, the program editor for DOP-100 series products and user manuals can be downloaded at our website. In addition, the content of this instruction sheet may be revised without prior notice.
Please consult our distributors or download the latest version at https://www.deltaww.com/zh-tw/index. -
DOP-100 series can be used for industrial automation equipment. Please read through this manual carefully and install the product according to the instructions to avoid danger.
Part Name | Hazardous Substances |
---|---|
(Pb) | (Hg) |
Metal Part | X |
Plastic Part | O |
Electronic | X |
Contacts | O |
Cable & Cabling accessories | X |
Battery | O |
This table is made according to SJ/T 11364.
O: Indicates that the concentration of hazardous substance in all of the
homogeneous materials for this part is below the limit as stipulated in GB/T
26572.
X: Indicates that concentration of hazardous substance in at least one of the
homogeneous materials used for this part is above the limit as stipulated in
GB/T 26572.
5014052100