FMS BKS.D.7 Winder GLIDE Linear Actuator Instruction Manual
- June 1, 2024
- Fms
Table of Contents
FMS BKS.D.7 Winder GLIDE Linear Actuator
This operation manual is also available in English.
Please contact your local representative.
© by FMS Force Measuring Systems AG, CH-8154 Oberglatt – All rights reserved.
Safety Information
All safety information, operating and installation regulations listed here
ensure proper function of the device. Safe operation of the system requires
compliance at all times. Noncompliance with the safety information or using
the device outside of the specified performance data can endanger the personal
safety.
Work with respect to operation, maintenance, retrofit, repair, or setting the
device described here must only be performed by qualified personnel.
Presentation of Safety Information
-
Danger that Could Result in Personal Injury
Danger, warning, caution
Type of danger and its source Possible consequences of nonobservance Measure for danger prevention -
Note Regarding Proper Function
Note
Note regarding proper operation
Simplification of operation
Ensuring function
General Safety Information
The linear actuators may not be subjected to loads outside of the specified
values during installation and operation. In particular, the device must not
be used outside of the temperature range and protection class.
The installation points on the machine frame must be designed correctly to
properly accommodate the installation of the actuator.
The linear actuator and related web guiding controller must be wired
correctly.
Product Information
Mode of Operation
The FMS winderGLIDE linear actuators feature a backlash-free ball screw driven by a BLDC motor. This enables precise corrections at high adjusting speeds. The linear actuator is connected to the web guiding controller using one cable only and an easily accessible connector. Its compact dimensions and various mounting options make the FMS winderGLIDE the ideal candidate for retrofit on existing systems.
Dimensions
Table 1: Dimensions
Dimensions mm (in.)
| BKS.D.7.200| BKS.D7.300
Stroke| 200 (7.87)| 300 (11.8)
A Centers of rod ends, fully retracted| 439 (9.4)| 539 (21.2)
B Total length main body| 363 (14.3)| 463 (18.2)
C Overall length, fully retracted| 471 (18.5)| 571 (22.5)
Order Code
Scope of Supply
The following is included in the scope of supply
- Linear actuator, rod ends on both sides
- Installation manual
The following is not included in the scope of supply
- Web guiding controller
- Mounting material
- Material sensor
- Connection cable to web guiding controller
Installation
Preparation
The FMS winderGLIDE linear actuators are defined as an “incomplete machine” in line with EC Directive 2006/42/EC, Article 2. When installing the FMS winderGLIDE, the following conditions must be met to ensure proper function and installation in a machine without negative impact on safety and health of persons:
- The linear actuators may not be subjected to loads outside of the specified values during installation and operation. In particular, the device must not be used outside of the temperature range and protection class.
- The installation points on the machine frame must be designed correctly to properly accommodate the installation of the actuator.
- The linear actuator and related web guiding controller must be wired correctly
Mounting Accessories
Table 2: Overview of mounting accessories
Overview and combination of mounting accessories
| Attachment to static end| Attachment to moving end
Rod end (in scope of supply)| Yes| Yes
Clevis (accessories)| Yes| Yes
Hinge (accessories)| Yes| No
Flange| Yes| No
Dimensions
Figure 3: Mounting Accessories
Warning
Damaging the push rod
When tightening the rod end, you must secure the push rod against twisting
using a hexagon wrench, otherwise the thread of the push rod may be damaged!!
The static part of the linear actuator must be mounted to the machine frame,
e.g., using the rod end on the housing or using the flange on the front part
of the spindle housing. The push rod of the actuator is mounted to the take-up
or pay-off station.
The FMS winderGLIDE is designed for installation in horizontal position.
Installation on Pay-off (Undwind) Station
Installation on Take-up (Rewind) Station
Figure 5: Installation on pay-off station
Tension_Control_Web_Guiding_Scheme_Schema.ai
Electrical Connection to Web Guiding Controllers of the BKS309 Series
Table 3: Terminal assignment on Web guiding controller BKS309 BKS309_BA_Manual.ai
Pin assignment of connector
PIN| Assignment
1| 24V motor
2| GND
3| Velocity set point +/-10V
4| GND logic
5| 0 to 10V potentiometer
6| +10 V potentiometer
7| GND motor
Technical Data
Table 4: Technical Data
Technical Data
Max. thrust force| 4’000N (900lbf)
Max. adjusting speed| 25 mm/s (0.98 in/s)
Drive| Stepper motor, 16 mm ball screw with 5 mm
pitch
Temperature range| –10 to +50 °C
Protection rating| IP42
Control accuracy| <±0.1 mm
Power consumption| Max. 160 W, from web guiding controller
Stroke limiting, travel measurement| Potentiometer
CUSTOMER SUPPORT
FMS Force Measuring Systems AG
Aspstrasse 6
8154 Oberglatt (Switzerland)
Tel. 0041 1 852 80 80
Fax 0041 1 850 60 06
info@fms-technology.com
www.fms-technology.com
FMS USA, Inc.
2155 Stonington Avenue Suite 119
Hoffman Estates,, IL 60169 (USA)
Tel. +1 847 519 4400
Fax +1 847 519 4401
fmsusa@fmstechnology.com
FMS (UK)
Aspstrasse 6
8154 Oberglatt (Switzerland)
Tel. +44 (0)1767 221 303
fmsuk@fms-technology.com