Baldwin Boulder AC Z-Wave Deadbolt 8252 Manual

June 8, 2024
BALDWIN

Table of Contents

Baldwin

Boulder AC Z-Wave Deadbolt

SKU: 8252

Quickstart

This is a
secure
Door Lock – Keypad
for
U.S. / Canada / Mexico
.

Please make sure the internal battery is fully charged.

To add this device to your network execute the following action:
Initiate the process to add the lock to your system at your smart home controller.When prompted by your smart home system to add the lock, press button A on the lock interior one time. The red LED will illuminate when the lock enters Add Mode.Please allow time for the controller to add the lock to your system.

Please refer to the
Manufacturers Manual
for more information.

Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.

Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This
device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message ( two- way
communication
) and every mains powered node can act as a repeater for other nodes
( meshed network ) in case the receiver is not in direct wireless range of the
transmitter.

This device and every other certified Z-Wave device can be used together with any other
certified Z-Wave device regardless of brand and origin
as long as both are suited for the
same frequency range.

If a device supports secure communication it will communicate with other devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to maintain
backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer
to www.z-wave.info.

Product Description

Baldwin, the leader in residential security, introduces the Boulder AC Electronic Deadbolt with Z-Wave.Backlit keypad with One touch locking30 user codesBHMA grade 2 certifiedFull 128-bit encryption securityDrill and pick resistant backup keywaySmartKey: Re-key the lock in seconds

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default
state.
Please make sure to reset the device into factory default. You can do this by
performing an Exclusion operation as described below in the manual. Every Z-Wave
controller is able to perform this operation however it is recommended to use the primary
controller of the previous network to make sure the very device is excluded properly
from this network.

Reset to factory default

This device also allows to be reset without any involvement of a Z-Wave controller. This
procedure should only be used when the primary controller is inoperable.

A factory reset will delete all user codes associated with the lock and will remove itself from your smart home system.Please only perform a factory reset when the primary controller is missing or inoperable.To perform a factory reset, please perform the following:1. Remove the battery pack2. Press and HOLD the Program button while reinserting the battery pack.3. Keep holding the button for 30 seconds until the lock beeps and the status LED flashes red.4. Press the Program button once more.The status LED will flash green and red several times.5. After a few seconds, the lock will initiate the door handing process.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs
to be added to an existing wireless network to communicate with the devices of this network.
This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network. This
controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is
then performed doing a special manual action right on the device.

Inclusion

Initiate the process to add the lock to your system at your smart home controller.When prompted by your smart home system to add the lock, press button A on the lock interior one time. The red LED will illuminate when the lock enters Add Mode.Please allow time for the controller to add the lock to your system.

Exclusion

Follow your smart home systems instructions to remove the lock from the network. When prompted by the system, press button A on the lock interior once.The red LED will illuminate when the lock enters Remove mode.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association – one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device
controlling another device is called association. In order to control a different
device, the controlling device needs to maintain a list of devices that will receive
controlling commands. These lists are called association groups and they are always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’ Command.

Association Groups:

Group NumberMaximum NodesDescription

1| 1| Z-Wave Plus LifelineSupports the following types of unsolicited messages:Battery Report – sends periodic battery reports containing the battery percentage.Door Lock Operation Report – upon power up, this message will be sent to allow the controller to sync up with the current lock status.Notification Report – many notification types will be sent for status and alarms.The following notification types are supported:Access Control (V2), Home Security (V2), and Power Management (V2).Device Reset Locally Notification – this message will be sent to notify the smart home controller that the lock is resetting back to factory defaults and will be leaving the network.
---|---|---
2| 5| This group will provide all Notification reports as described for the Lifeline.This group allows other controllers, other than the lifeline, to receive these types of unsolicited messages as well.

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock further
enhanced features.

IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56.
In case of a two byte value the same logic applies: Values greater than 32768 may
needed to be given as negative values too.

Parameter 1: User Code Type for User Code 1

This configuration parameter is used to get or set the type of user for their corresponding user code. By default, all user codes are set to the Owner type unless otherwise specified. The parameter type is associated with the user code location 1. Caution must be used when setting these values. Guests and Workers will require schedules attached to them in order for those types to be assigned.
Size: 1 Byte, Default Value: 1

SettingDescription

1 Owner
3 Guest
4 Worker

Parameter 10: User Code Type for User Code 10

This configuration parameter is used to get or set the type of user for their corresponding user code. By default, all user codes are set to the Owner type unless otherwise specified. The parameter type is associated with the user code location 10. Caution must be used when setting these values. Guests and Workers will require schedules attached to them in order for those types to be assigned.
Size: 1 Byte, Default Value: 1

SettingDescription

1 Owner
3 Guest
4 Worker

Parameter 11: User Code Type for User Code 11

This configuration parameter is used to get or set the type of user for their corresponding user code. By default, all user codes are set to the Owner type unless otherwise specified. The parameter type is associated with the user code location 11. Caution must be used when setting these values. Guests and Workers will require schedules attached to them in order for those types to be assigned.
Size: 1 Byte, Default Value: 1

SettingDescription

1 Owner
3 Guest
4 Worker

Parameter 12: User Code Type for User Code 12

This configuration parameter is used to get or set the type of user for their corresponding user code. By default, all user codes are set to the Owner type unless otherwise specified. The parameter type is associated with the user code location 12. Caution must be used when setting these values. Guests and Workers will require schedules attached to them in order for those types to be assigned.
Size: 1 Byte, Default Value: 1

SettingDescription

1 Owner
3 Guest
4 Worker

Parameter 13: User Code Type for User Code 13

This configuration parameter is used to get or set the type of user for their corresponding user code. By default, all user codes are set to the Owner type unless otherwise specified. The parameter type is associated with the user code location 13. Caution must be used when setting these values. Guests and Workers will require schedules attached to them in order for those types to be assigned.
Size: 1 Byte, Default Value: 1

SettingDescription

1 Owner
3 Guest
4 Worker

Parameter 14: User Code Type for User Code 14

This configuration parameter is used to get or set the type of user for their corresponding user code. By default, all user codes are set to the Owner type unless otherwise specified. The parameter type is associated with the user code location 14. Caution must be used when setting these values. Guests and Workers will require schedules attached to them in order for those types to be assigned.
Size: 1 Byte, Default Value: 1

SettingDescription

1 Owner
3 Guest
4 Worker

Parameter 15: User Code Type for User Code 15

This configuration parameter is used to get or set the type of user for their corresponding user code. By default, all user codes are set to the Owner type unless otherwise specified. The parameter type is associated with the user code location 15. Caution must be used when setting these values. Guests and Workers will require schedules attached to them in order for those types to be assigned.
Size: 1 Byte, Default Value: 1

SettingDescription

1 Owner
3 Guest
4 Worker

Parameter 16: User Code Type for User Code 16

This configuration parameter is used to get or set the type of user for their corresponding user code. By default, all user codes are set to the Owner type unless otherwise specified. The parameter type is associated with the user code location 16. Caution must be used when setting these values. Guests and Workers will require schedules attached to them in order for those types to be assigned.
Size: 1 Byte, Default Value: 1

SettingDescription

1 Owner
3 Guest
4 Worker

Parameter 17: User Code Type for User Code 17

This configuration parameter is used to get or set the type of user for their corresponding user code. By default, all user codes are set to the Owner type unless otherwise specified. The parameter type is associated with the user code location 17. Caution must be used when setting these values. Guests and Workers will require schedules attached to them in order for those types to be assigned.
Size: 1 Byte, Default Value: 1

SettingDescription

1 Owner
3 Guest
4 Worker

Parameter 18: User Code Type for User Code 18

This configuration parameter is used to get or set the type of user for their corresponding user code. By default, all user codes are set to the Owner type unless otherwise specified. The parameter type is associated with the user code location 18. Caution must be used when setting these values. Guests and Workers will require schedules attached to them in order for those types to be assigned.
Size: 1 Byte, Default Value: 1

SettingDescription

1 Owner
3 Guest
4 Worker

Parameter 19: User Code Type for User Code 19

This configuration parameter is used to get or set the type of user for their corresponding user code. By default, all user codes are set to the Owner type unless otherwise specified. The parameter type is associated with the user code location 19. Caution must be used when setting these values. Guests and Workers will require schedules attached to them in order for those types to be assigned.
Size: 1 Byte, Default Value: 1

SettingDescription

1 Owner
3 Guest
4 Worker

Parameter 2: User Code Type for User Code 2

This configuration parameter is used to get or set the type of user for their corresponding user code. By default, all user codes are set to the Owner type unless otherwise specified. The parameter type is associated with the user code location 2. Caution must be used when setting these values. Guests and Workers will require schedules attached to them in order for those types to be assigned.
Size: 1 Byte, Default Value: 1

SettingDescription

1 Owner
3 Guest
4 Worker

Parameter 20: User Code Type for User Code 20

This configuration parameter is used to get or set the type of user for their corresponding user code. By default, all user codes are set to the Owner type unless otherwise specified. The parameter type is associated with the user code location 20. Caution must be used when setting these values. Guests and Workers will require schedules attached to them in order for those types to be assigned.
Size: 1 Byte, Default Value: 1

SettingDescription

1 Owner
3 Guest
4 Worker

Parameter 21: User Code Type for User Code 21

This configuration parameter is used to get or set the type of user for their corresponding user code. By default, all user codes are set to the Owner type unless otherwise specified. The parameter type is associated with the user code location 21. Caution must be used when setting these values. Guests and Workers will require schedules attached to them in order for those types to be assigned.
Size: 1 Byte, Default Value: 1

SettingDescription

1 Owner
3 Guest
4 Worker

Parameter 22: User Code Type for User Code 22

This configuration parameter is used to get or set the type of user for their corresponding user code. By default, all user codes are set to the Owner type unless otherwise specified. The parameter type is associated with the user code location 22. Caution must be used when setting these values. Guests and Workers will require schedules attached to them in order for those types to be assigned.
Size: 1 Byte, Default Value: 1

SettingDescription

1 Owner
3 Guest
4 Worker

Parameter 23: User Code Type for User Code 23

This configuration parameter is used to get or set the type of user for their corresponding user code. By default, all user codes are set to the Owner type unless otherwise specified. The parameter type is associated with the user code location 23. Caution must be used when setting these values. Guests and Workers will require schedules attached to them in order for those types to be assigned.
Size: 1 Byte, Default Value: 1

SettingDescription

1 Owner
3 Guest
4 Worker

Parameter 24: User Code Type for User Code 24

This configuration parameter is used to get or set the type of user for their corresponding user code. By default, all user codes are set to the Owner type unless otherwise specified. The parameter type is associated with the user code location 24. Caution must be used when setting these values. Guests and Workers will require schedules attached to them in order for those types to be assigned.
Size: 1 Byte, Default Value: 1

SettingDescription

1 Owner
3 Guest
4 Worker

Parameter 25: User Code Type for User Code 25

This configuration parameter is used to get or set the type of user for their corresponding user code. By default, all user codes are set to the Owner type unless otherwise specified. The parameter type is associated with the user code location 25. Caution must be used when setting these values. Guests and Workers will require schedules attached to them in order for those types to be assigned.
Size: 1 Byte, Default Value: 1

SettingDescription

1 Owner
3 Guest
4 Worker

Parameter 26: User Code Type for User Code 26

This configuration parameter is used to get or set the type of user for their corresponding user code. By default, all user codes are set to the Owner type unless otherwise specified. The parameter type is associated with the user code location 26. Caution must be used when setting these values. Guests and Workers will require schedules attached to them in order for those types to be assigned.
Size: 1 Byte, Default Value: 1

SettingDescription

1 Owner
3 Guest
4 Worker

Parameter 27: User Code Type for User Code 27

This configuration parameter is used to get or set the type of user for their corresponding user code. By default, all user codes are set to the Owner type unless otherwise specified. The parameter type is associated with the user code location 27. Caution must be used when setting these values. Guests and Workers will require schedules attached to them in order for those types to be assigned.
Size: 1 Byte, Default Value: 1

SettingDescription

1 Owner
3 Guest
4 Worker

Parameter 28: User Code Type for User Code 28

This configuration parameter is used to get or set the type of user for their corresponding user code. By default, all user codes are set to the Owner type unless otherwise specified. The parameter type is associated with the user code location 28. Caution must be used when setting these values. Guests and Workers will require schedules attached to them in order for those types to be assigned.
Size: 1 Byte, Default Value: 1

SettingDescription

1 Owner
3 Guest
4 Worker

Parameter 29: User Code Type for User Code 29

This configuration parameter is used to get or set the type of user for their corresponding user code. By default, all user codes are set to the Owner type unless otherwise specified. The parameter type is associated with the user code location 29. Caution must be used when setting these values. Guests and Workers will require schedules attached to them in order for those types to be assigned.
Size: 1 Byte, Default Value: 1

SettingDescription

1 Owner
3 Guest
4 Worker

Parameter 3: User Code Type for User Code 3

This configuration parameter is used to get or set the type of user for their corresponding user code. By default, all user codes are set to the Owner type unless otherwise specified. The parameter type is associated with the user code location 3. Caution must be used when setting these values. Guests and Workers will require schedules attached to them in order for those types to be assigned.
Size: 1 Byte, Default Value: 1

SettingDescription

1 Owner
3 Guest
4 Worker

Parameter 30: User Code Type for User Code 30

This configuration parameter is used to get or set the type of user for their corresponding user code. By default, all user codes are set to the Owner type unless otherwise specified. The parameter type is associated with the user code location 30. Caution must be used when setting these values. Guests and Workers will require schedules attached to them in order for those types to be assigned.
Size: 1 Byte, Default Value: 1

SettingDescription

1 Owner
3 Guest
4 Worker

Parameter 31: Dipswitch settings

This is a one byte read only bit mask that returns the state of the user accessible dipswitches on the rear panel of the door lock.0x01: Lock Status LED (1: enabled, 0: disabled)0x02: Autolock setting (1: enabled, 0: disabled)0x04: Buzzer (1: enabled, 0: disabled)
Size: 1 Byte, Default Value: 5

SettingDescription

0 All features disabled
1 Lock Status LED enabled
2 Autolock enabled
3 Autolock & Lock status LED enabled
4 Internal Buzzer enabled
5 Internal buzzer & Lock status LED enabled
7 All features enabled

Parameter 33: SKU number, 1st 4 bytes

This configuration parameter provides the first 4 bytes of the SKU number that has been programmed into the lock.Each byte allows all printable characters from 32 to 126.
Size: 4 Byte, Default Value: 32

SettingDescription

32 – 126 All printable characters

Parameter 34: SKU number, last 4 bytes

This configuration parameter provides the second and last 4 bytes of the SKU number that has been programmed into the lock.Each byte allows all printable characters from 32 to 126.
Size: 4 Byte, Default Value: 32

SettingDescription

32 – 126 All printable characters

Parameter 4: User Code Type for User Code 4

This configuration parameter is used to get or set the type of user for their corresponding user code. By default, all user codes are set to the Owner type unless otherwise specified. The parameter type is associated with the user code location 4. Caution must be used when setting these values. Guests and Workers will require schedules attached to them in order for those types to be assigned.
Size: 1 Byte, Default Value: 1

SettingDescription

1 Owner
3 Guest
4 Worker

Parameter 40: Reset to Default

This configuration parameter allows the smart home controller to force a factory reset of the lock.After receiving this request, the lock will send a Device Reset Locally message back to the lifeline controller.
Size: 1 Byte, Default Value: 0

SettingDescription

0 No action taken
1 Force Factory Reset

Parameter 5: User Code Type for User Code 5

This configuration parameter is used to get or set the type of user for their corresponding user code. By default, all user codes are set to the Owner type unless otherwise specified. The parameter type is associated with the user code location 5. Caution must be used when setting these values. Guests and Workers will require schedules attached to them in order for those types to be assigned.
Size: 1 Byte, Default Value: 1

SettingDescription

1 Owner
3 Guest
4 Worker

Parameter 6: User Code Type for User Code 6

This configuration parameter is used to get or set the type of user for their corresponding user code. By default, all user codes are set to the Owner type unless otherwise specified. The parameter type is associated with the user code location 6. Caution must be used when setting these values. Guests and Workers will require schedules attached to them in order for those types to be assigned.
Size: 1 Byte, Default Value: 1

SettingDescription

1 Owner
3 Guest
4 Worker

Parameter 7: User Code Type for User Code 7

This configuration parameter is used to get or set the type of user for their corresponding user code. By default, all user codes are set to the Owner type unless otherwise specified. The parameter type is associated with the user code location 7. Caution must be used when setting these values. Guests and Workers will require schedules attached to them in order for those types to be assigned.
Size: 1 Byte, Default Value: 1

SettingDescription

1 Owner
3 Guest
4 Worker

Parameter 8: User Code Type for User Code 8

This configuration parameter is used to get or set the type of user for their corresponding user code. By default, all user codes are set to the Owner type unless otherwise specified. The parameter type is associated with the user code location 8. Caution must be used when setting these values. Guests and Workers will require schedules attached to them in order for those types to be assigned.
Size: 1 Byte, Default Value: 1

SettingDescription

1 Owner
3 Guest
4 Worker

Parameter 9: User Code Type for User Code 9

This configuration parameter is used to get or set the type of user for their corresponding user code. By default, all user codes are set to the Owner type unless otherwise specified. The parameter type is associated with the user code location 9. Caution must be used when setting these values. Guests and Workers will require schedules attached to them in order for those types to be assigned.
Size: 1 Byte, Default Value: 1

SettingDescription

1 Owner
3 Guest
4 Worker

Technical Data

Hardware Platform ZM5101
Device Type Door Lock – Keypad
Network Operation Listening Sleeping Slave
Firmware Version HW: 2 FW: 4.10:56.12
Z-Wave Version 6.51.08
Certification ID ZC10-18096235
Z-Wave Product Id 0x0090.0x0009.0x0238
Supported Notification Types Access ControlHome SecurityPower Management
Door Lock Type Deadbolt
Firmware Updatable Updatable by Consumer by RF
Frequency XXfrequency
Maximum transmission power XXantenna

Supported Command Classes

  • Antitheft V2
  • Association Grp Info
  • Association V2
  • Battery
  • Configuration
  • Device Reset Locally
  • Door Lock Logging
  • Door Lock V2
  • Firmware Update Md V3
  • Manufacturer Specific V2
  • Notification V4
  • Powerlevel
  • Schedule Entry Lock V2
  • Security
  • Time Parameters
  • User Code
  • Version V2
  • Zwaveplus Info V2

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network.
    Controllers are typically Gateways,Remote Controls or battery operated wall controllers.

  • Slave — is a Z-Wave device without capabilities to manage the network.
    Slaves can be sensors, actuators and even remote controls.

  • Primary Controller — is the central organizer of the network. It must be
    a controller. There can be only one primary controller in a Z-Wave network.

  • Inclusion — is the process of adding new Z-Wave devices into a network.

  • Exclusion — is the process of removing Z-Wave devices from the network.

  • Association — is a control relationship between a controlling device and
    a controlled device.

  • Wakeup Notification — is a special wireless message issued by a Z-Wave
    device to announces that is able to communicate.

  • Node Information Frame — is a special wireless message issued by a
    Z-Wave device to announce its capabilities and functions.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals