FMS BKS.D.3 Linear Actuator Instruction Manual
- June 1, 2024
- Fms
Table of Contents
Installation Manual
FMS winderGLIDE Type BKS.D.3
Actuator for unwind and rewind stations
Document Version 1.10 12/2023 NS
This operation manual is also available in German.
Please contact your local representative.
Safety Instructions
1.1 Description Conditions
a) High danger of health injury or loss of life
Danger
This symbol refers to high risk for persons to get health injury or loss of
life. It has to be followed strictly.
b) Risk of damage of machines
Caution
This symbol refers to information, that, if ignored, could cause heavy
mechanical damage. This warning has to be followed absolutely.
c) Note for proper function
Note
This symbol refers to an important information about proper use. If not
followed, malfunction can be the result.
1.2 List of Safety Instructions
The winderGLIDE BKS.D.3 may not be stressed over the specification limits
neither during assembly nor operation. In particular it may not be operated
outside the specified temperature range and protection class.
The attachment points for the winderGLIDE on the machine must be properly
designed
For correct installation and operation, follow the electrical wiring diagram
and instructions in this manual.
Product Data
2.1 Mechanical Dimensions
Dimensions (see Fig. 1) | in mm and [in] |
---|---|
Steering offset L | 125 [4.92] or 200 [7.87] |
Bracket distance A in center position of toggle link sockets | 236 [9.29] + L |
Total length B at full travel positions | 236 [9.29] + 2L |
Total length C | 266 [9.29] + L |
Screw pitch | 5 [0.2] |
2.2 Order Code (Example) winderGLIDE Type D.3
2.3 Scope of Delivery
Actuator with spherical rod ends on both sides
Not included in the scope of delivery are the preassembled cable and
alternative mounting devices. Additional mounting devices like clevis, hinge
or flange for front mounting can be ordered separately.
Installation
3.1 Assembly Conditions
The winderGLIDE BKS.D.3 is defined as “partly completed machinery” according
to the Directives 2006/42/EC, article 2. In order to assure a proper
functionality of the parts and guarantee the essential health and safety
requirements of operators working with it, the following conditions for the
assembly of the winderGLIDE must be met:
Caution
The winderGLIDE BKS.D.3 may not be stressed over the specification limits
neither during assembly nor operation. In particular it may not be operated
outside the specified temperature range and protection class.
Caution
The attachment points for the winderGLIDE on the machine must be properly
designed.
Caution
For correct installation and operation, follow the electrical wiring diagram
and instructions in this manual (ref to Fig. 3 “Pin Assignment”) .
3.2 Mounting the winderGLIDE Type D.3
There are four mounting devices to assemble the winderGLIDE on the machine
frame
These mounting devices can be combined according to the table below to meet
the requirements of the application (see also Fig.2).
Mounting devices | Joint at the static end | Joint at the moving end |
---|---|---|
Spherical rod end | ● | ● |
Clevis | ● | ● |
Hinge | ● | – |
Flange | ● | – |
Caution
When tightening the rod end, you must secure the push rod against twisting
using a hexagon wrench, otherwise the thread of the push rod may be damaged!
The static part of the winderGLIDE must be mounted to the machine frame e.g by
means of the spherical rod end on the gearbox or the flange at the end of the
spindle housing. The moving rod end is mounted to the winding stand. The
BKS.D.3 was designed for horizontal mounting positions.
3.1 Installation on unwinding station
3.2 Installation on winding station
3.3 Pin Assignment
Functional Description
The FMS-winderGLIDE D.3 is a dedicated actuator for the use in unwind and
rewind stations.
The stepper motor equipped drive is powerful and simple in its application.
The used technology is clean. Specially when used in the food and
pharmaceutical packaging industry the FMS-winderGLIDE D.3 has huge advantages
compared to hydraulic drives. The FMS-winderGLIDE is designed around an
accurate spindle and ball screw which makes the devise very precise. The
easily accessible connector and its pacesaving design make the FMS-actuator
very suitable for upgrading existing installations.
Technical Specification
Parameter | Specification |
---|---|
Spindle Pitch | 5 |
Thrust Force [N] | 650 |
Adjusting Speed [mm/s] | 25 |
Drive | 16mm spindle, ball screw combination |
Temperature Range | -10 … 60 °C (14…140 °F) |
Protection Class | IP40 |
FMS Force Measuring Systems AGAspstrasse 6
8154 Oberglatt (Switzerland)
Tel. +41 44 852 80 80
Fax +41 44 850 60 06
info@fms-technology.com
www.fms-technology.com | FMS Italy
Via Baranzate 67
I-20026 Novate Milanese
Tel: +39 02 39487035
Fax: +39 02 39487035
fmsit@fms-technology.com | FMS USA,
Inc.
2155 Stonington Ave. Suite 119
Hoffman Estates, IL 60169 USA
Tel. +1 847 519 4400
Fax +1 847 519 4401
fmsusa@fms-technology.com | FMS UK
Highfield, Atch Lench Road
Church Lench
Evesham WR11 4UG, Great Britain
Tel. +44 1386 871023
Fax +44 1386 871021
fmsuk@fms-technology.com
---|---|---|---