HANYOUNG NUX HSR-2E Single Phase 2 Wire Control Overcurrent Sensing Solid State Relay Instruction Manual

June 16, 2024
HANYOUNG NUX

HANYOUNG-NUX-LOGO

HANYOUNG NUX HSR-2E Single Phase 2 Wire Control Overcurrent Sensing Solid

State Relay

HANYOUNG-NUX-HSR-2E-Single-Phase-2-Wire-Control-Overcurrent-Sensing-Solid-
State-Relay-PRODUCT

Thank you for purchasing Hanyoung Nux products. Please read the instruction manual carefully before using this product, and use the product correctly.
Also, please keep this instruction manual where you can view it at any time.

Safety information

Please read the safety information carefully before use, and use the product correctly.
The alerts declared in the manual are classified into Danger, Warning and Caution according to their importance.

DANGER Indicates an imminently hazardous situation that, if not avoided, will result in death or serious injury
WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury
CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor injury or property damage

DANGER

The input/output terminals are subject to electric shock risk. Never let the input/output terminals come in contact with your body or conductive substances.

WARNING

  • When used in equipment with a high risk of personal injury or property damage (examples: medical devices, nuclear control, ships, aircraft, vehicles, railways, combustion devices, safety devices, crime/disaster prevention equipment etc.) install double safety devices and prevent accidents. Failure to do so may result in fire, personnel accident or property damage.
  • Please read the safety information carefully before use, and use the product correctly.
  • If there is a possibility that a malfunction or abnormality of this product may lead to a serious accident, install an appropriate protection circuit on the outside and plan to prevent accidents.
  • Please supply the rated power voltage, to prevent product breakdowns or malfunctions.
  • To prevent electric shocks and malfunctions, do not supply power until the wiring is completed.
  • Please disassemble the product after turning OFF the power.
  • Any use of the product other than those specified by the manufacturer may result in personal injury or property damage.
  • Please use this product after installing it to a panel, because there is a risk of electric shock.

CAUTION

  • Please make sure that the product specifications are the same as you ordered.
  • Please use the product in places where corrosive gases (especially harmful gases, ammonia, etc.) and flammable gases are not generated.
  • Please use the product in places without liquids, oils, chemicals, steam, dust, salt, iron, etc. (pollution degree 1 or 2).
  • Please avoid places where large inductive interference, static electricity, and magnetic noise are generated.
  • Please avoid places with heat accumulation caused by direct sunlight, radiant heat, etc.
  • When water enters, a short circuit or fire may occur, so please inspect the product carefully.
  • Do not connect anything to the unused terminals.
  • For DC types, please wire correctly, after checking the polarity of the terminals.
  • When using the SSR, the product may be damaged if the specified heat sink is not used. Be sure to use the specified heat sink.
  • When disposing of the product, treat it as industrial waste.

Suffix code

HANYOUNG-NUX-HSR-2E-Single-Phase-2-Wire-Control-Overcurrent-Sensing-Solid-
State-Relay-FIG-24

Specifications

HANYOUNG-NUX-HSR-2E-Single-Phase-2-Wire-Control-Overcurrent-Sensing-Solid-
State-Relay-FIG-25

Description of Each Part

HANYOUNG-NUX-HSR-2E-Single-Phase-2-Wire-Control-Overcurrent-Sensing-Solid-
State-Relay-FIG-26

Connection Example

Caution

  • This product does not have an internal fuse.
  • We recommend using an external fast-acting fuse as shown in the diagram.
  • Operating circuit power: terminals 7 and 8.
  • Control signal input: terminals 13 and 14.

HANYOUNG-NUX-HSR-2E-Single-Phase-2-Wire-Control-Overcurrent-Sensing-Solid-
State-Relay-FIG-4

Load Current Characteristics

HANYOUNG-NUX-HSR-2E-Single-Phase-2-Wire-Control-Overcurrent-Sensing-Solid-
State-Relay-FIG-5

LED Status Display and Function

HANYOUNG-NUX-HSR-2E-Single-Phase-2-Wire-Control-Overcurrent-Sensing-Solid-
State-Relay-FIG-27

Description of Automatic Mode Jog Operation

HANYOUNG-NUX-HSR-2E-Single-Phase-2-Wire-Control-Overcurrent-Sensing-Solid-
State-Relay-FIG-28

How to use User Setup Menu

  1. Press and hold Jog on the main screen to enter the user settings menu.
  2. On the user setting menu screen, the parameter name is displayed for 1 second, then blinks twice and the parameter setting value is displayed repeatedly.
  3. Rotate the jog left/right on the user setting menu screen to change the parameter setting value.
  4. If you press the jog button once briefly, you can enter the parameter setting value editing screen.
  5. After completing the setting, press and hold the jog on the user setting menu screen to save and return to the main screen.

If there is no operation for more than 5 seconds, it will automatically return to the main screen without saving.

Description of User Settings Menu Display

HANYOUNG-NUX-HSR-2E-Single-Phase-2-Wire-Control-Overcurrent-Sensing-Solid-
State-Relay-FIG-6

Note 1) Overload current value depends on the model ▶ 15A ▶ 25A ▶ 35A

Display of User Assistance Menu Screen

HANYOUNG-NUX-HSR-2E-Single-Phase-2-Wire-Control-Overcurrent-Sensing-Solid-
State-Relay-FIG-7

Manual Mode Description

(Stand Alone Control)
Cannot be used except for adjusting the amount of output

HANYOUNG-NUX-HSR-2E-Single-Phase-2-Wire-Control-Overcurrent-Sensing-Solid-
State-Relay-FIG-29

Installation Clearance

HANYOUNG-NUX-HSR-2E-Single-Phase-2-Wire-Control-Overcurrent-Sensing-Solid-
State-Relay-FIG-9

Caution

  • Please ensure that the installation clearance is at least the dimension indicated in the diagram.
  • When installing wiring ducts, please make sure they are installed with a height of no more than half of the heat sink plate to avoid obstructing the airflow.
  • HSR is designed to meet the specified conditions at ambient temperatures of 25℃ or below. Please use the product under conditions where the ambient temperature is always lower than the specified temperature.
  • When installing HSR, be sure to install the heat sink plate in the vertical direction.
  • If installed horizontally, the product’s performance will be reduced by 50% or more.

Installation Method

HANYOUNG-NUX-HSR-2E-Single-Phase-2-Wire-Control-Overcurrent-Sensing-Solid-
State-Relay-FIG-10

Caution

  1. Torque selection
    • Input/Output terminals: 0.25 Nm
  2. Modification of terminal wiring notation
  • Input terminal wiring (10 A / 20 A / 30 A)
  • 1.31SQ (mm2)
  • Output terminal wiring
  • 10A: 1.31SQ (mm2)
  • 20A: 4.17SQ (mm2)
  • 30A: 5.26SQ (mm2)

Flow Chart

Reading parameters (example)

HANYOUNG-NUX-HSR-2E-Single-Phase-2-Wire-Control-Overcurrent-Sensing-Solid-
State-Relay-FIG-30

Display on FND

Initial value setting

  • Setting value: 1 ~ 99 sec
  • Factory setting value: 1 sec
  • Initial power-on waiting time setting

Entering User Menu

(Jog push down for 1 second or more.)

HANYOUNG-NUX-HSR-2E-Single-Phase-2-Wire-Control-Overcurrent-Sensing-Solid-
State-Relay-FIG-14 HANYOUNG-NUX-HSR-2E-Single-Phase-2-Wire-Control-Overcurrent-
Sensing-Solid-State-Relay-FIG-15 HANYOUNG-NUX-HSR-2E-
Single-Phase-2-Wire-Control-Overcurrent-Sensing-Solid-State-Relay-
FIG-16 HANYOUNG-NUX-HSR-2E-Single-Phase-2-Wire-Control-Overcurrent-Sensing-Solid-
State-Relay-FIG-17

Entering Auxiliary Menu
(Rotate jog to the right.)

HANYOUNG-NUX-HSR-2E-Single-Phase-2-Wire-Control-Overcurrent-Sensing-Solid-
State-Relay-FIG-19

Alarm display list

HANYOUNG-NUX-HSR-2E-Single-Phase-2-Wire-Control-Overcurrent-Sensing-Solid-
State-Relay-FIG-20 HANYOUNG-NUX-HSR-2E-Single-Phase-2-Wire-Control-Overcurrent-
Sensing-Solid-State-Relay-FIG-21 HANYOUNG-NUX-HSR-2E-
Single-Phase-2-Wire-Control-Overcurrent-Sensing-Solid-State-Relay-
FIG-22

Dimensions

HANYOUNG-NUX-HSR-2E-Single-Phase-2-Wire-Control-Overcurrent-Sensing-Solid-
State-Relay-FIG-23

CONTACT

HANYOUNGNUX CO., LTD

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

HANYOUNG NUX User Manuals

Related Manuals