INTRODUCTION & WARRANTY
Thank you for selecting and buying V-TAC product. V-TAC will serve you the
best. Please read these instructions carefully before starting the
installation and keep this manual handy for future reference. If you have any
another query, please contact our dealer or local vendor from whom you have
purchased the product. They are trained and ready to serve you at the best.
The warranty is valid for 3 years from the date of purchase. The warranty does
not apply to damage caused by incorrect installation or abnormal wear and
tear. The company gives no warranty against damage to any surface due to
incorrect removal and installation of the product. The products are suitable
for 10-12 Hours Daily operation. Usage of product for 24 Hours a day would
void the warranty. This product is warranted for manufacturing defects only.
This marking indicates that this product should not be disposed of with other household wastes.
Caution, risk of electric shock.
WARNING
- Please make sure to turn off the power before starting the installation.
- Installation must be performed by a qualified electrician
- The light source of this luminaire is not replaceable, when the light source reaches its end of life the whole luminaire should be replaced.
- If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard.
- Proper grounding should be ensured throughout the installation.
- Please do not install on a surface that is prone to vibrations.
- Contact our customer support team for battery replacement.
INSTALLATION PRECAUTIONS
- Microwave sensor can be installed in any lamp except the one with full metal shell.
- The detected surface cannot be shielded by metal objects.
- Make sure the microwave module is completely exposed outside.
- The detection surface of the sensor module shall be installed facing the detection area.
- Should be kept away from the driver to avoid interference generation and lamp flashing.
- Wiring must be strictly in accordance with the wiring diagram to avoid short circuit
USER NOTES
- 3M distance is suggested when having a lot sensors in one same room.
- If the sensor is applicated in the room with 5G WiFi router, 3M distance or above is needed.
INSTALLATION INSTRUCTION
INSTALLATION INSTRUCTIONS
-
Switch OFF the power before starting the installation.
-
Mark and drill the holes on the wall/surface at the correct space for the two surface mounting kits, and fix the kits on the wall/surface.
-
Unfasten securing clips.
-
Gently open the front cover/diffuser from the backside fitting.
-
Click backside fitting to surface mounting kits, Choose suitable Wattage & Colour Temperature by Dip Switch on LED driver.
-
Connect supply leads with terminal brown (L) to brown, blue (N) to blue & greenish-yellow ( )
to greenish-yellow. -
Gently put the front cover/diffuser to the backside fitting.
-
Fasten securing clips.
-
Switch ON the power to test the light.
LINKABLE UNITS WIRING DIAGRAM
SENSOR SETTINGS
DETECTION AREA – It can be adjusted by combining DIP switches for
specific application [FIG 1].
HOLD TIME – Time period during which the light will be ON after the last
detection [FIG 2].
DAYLIGHT THRESHOLD – Daylight sensor priors motion sensor. Set Threshold
for Specific needs.
If disabled, only motion sensor will work [FIG 3].
STAND-BY DIMMING LEVEL – The dimming level during which the light is ON
during the stand-by Period [FIG 4].
STAND-BY PERIOD – This is the time period during which the light keeps
dimming down after the last detection [FIG 5].
AUTOMATICALLY ON/OFF FUNCTION
DAYLIGHT DISABLE
CORRIDOR FUNCTION, BI-LEVEL DIMMABLE
REMOTE CONTROL (PURCHASE SEPERATELY)
REMARK
Indicator light on the remote will blink once every time it successfully
delivers command.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>