GPS FC48-AC Air Ionization System Instruction Manual
- June 1, 2024
- GPS
Table of Contents
GPS FC48-AC Air Ionization System Instruction Manual
NOTICE: This product is to be used only as directed. Read entire manual before use. Do not use unless properly installed.
Thank you for purchasing a GPS-FC48-AC air ionization system from GPS Air.
Hardware Provided by GPS
Before you start, confirm the contents of your shipment. Each GPS-FC48-AC will consist of the following.
- GPS-FC48-AC with in line power switch.
- Rare earth magnets (2).
- Machine screws and nuts (2 each) for mounting magnets.
Hardware by Others
- Electrical wiring, junction box, or receptacle to provide power to the GPS-FC48-AC.
- Self-tapping screws (optional) if not using magnet mount.
Installation Location
WARNING: MAKE SURE POWER IS DISCONNECTED TO THE HVAC EQUIPMENT BEFORE INSTALLATION.
GPS recommends mounting the GPS-FC48-AC on the blower housing on the side opposite the motor. Alternate mounting locations are on the supply air duct or the return air duct after the system filter. The emitter brushes should be no closer than two inches from any wiring or metal objects.
Care should be taken to avoid mounting in locations that are heavily moisture laden and/or dead air spots where there is no flow of the airstream over the ionizer.
NOTE: Use Temperature – Maximum Ambient temperature in which unit shall be used: 140 degree F/ 60°C.
Mechanical Installation
-
Ensure power to the HVAC equipment and the circuit the GPS-FC48-AC will be connected to has been turned off.
-
Find an appropriate location. Verify the carbon fiber emitters have a 2” clearance from wires or other metal objects.
-
Mount the magnets to the GPS-FC48-AC using included hardware. See FIGURE 1.
-
Install the GPS-FC48-AC so that airflow is passing by both emitters at the same time (like a football through goalposts).
-
Check that the wiper arm has room to rotate freely.
Wiring
-
Confirm the power is off prior to wiring. Follow all local and national electrical and building codes.
-
GPS recommends the GPS-FC48 be powered constantly and NOT switched with the system or blower.
-
The GPS-FC48-AC will self-adjust to voltages from 24VAC to 240VAC. Output and performance will not be effected by choice of input voltage. Connect the power wires as follows:
Black 24 – 240VAC
White Neutral or L2
Green Ground
Brown Dry Contacts/BAS terminals -
Wire in BAS terminals (optional). The GPS-FC48-AC is equipped with dry contacts that are normally open and close when the GPS-FC48-AC is on and has no faults. The contacts are rated up to 250VAC and 1A.
Operation
CAUTION! NEVER TOUCH BRUSHES WHILE OPERATING, SHOCK MAY OCCUR
Once powered, the unit initiates an internal check of all systems. If the auto cleaning wiper blade is not in the “home” position, it will move to the home position in series with the airflow and a green LED on the GPS-FC48 AC will illuminate.
Cleaning Cycle
The GPS-FC48-AC comes with a preset cleaning cycle designed to clean the
brushes every three days. The cleaning process may be activated by pushing the
test button located on the top of the unit. To change the cycle frequency,
press the cleaning cycle button once. While cleaning is in progress press and
hold the cleaning cycle button for 5 seconds.
The LED will start flashing. Pressing the cleaning cycle button again will
change the days between cleaning. The number of flashes indicates the cleaning
interval in days (3 flashes=3 days, 5 flashes=5 days).
Troubleshooting
-
Unit will not power up, LED not illuminated:
a. Confirm proper voltage is applied to the correct terminal(s).
a. Try an alternate power source. If using 24v try using 120v or vice versa. -
Wiper sticks or stops on emitters:
a. Adjust height of emitters: loosen screw at base of emitter gently push or pull emitter to a height where wiper just contacts emitter. Hold the emitter in place and tighten screw. Verify correct height after tightening screw. -
Wiper does not clean/ contact emitters:
a. Adjust height of emitters: loosen screw at base of emitter gently push or pull emitter to a height where wiper just contacts emitter. Hold the emitter in place and tighten screw. Verify correct height after tightening screw.
a. If the emitter is worn to the point where there is no adjustment, replacement emitters can be ordered from GPS. Remove the screw and the emitter base, unplug the emitter from the connector. Plug the new emitter in, reinstall base, adjust emitter height and tighten screw. -
If unit does not operate properly after verifying the above instructions please contact GPS for additional assistance.
The information provided in this manual is up to date at the time of printing. Any revisions to this document will supersede the content included. For the latest applicable version of this manual, visit our website or utilize the QR code.
3101 Yorkmont Road Suite 1500 Charlotte, NC 28208 980-279-5622
To access a list of applicable patents, please visit gpspatents.com
© 2023 GPS Air
GPS Air is the owner of certain trademarks that appear in our materials.
Please visit www.gpsair.com/trademarks for
a list of our marks.
References
- Patents | Global Plasma Solutions
- Environmental Claim Validation | UL
- GPS Air | Optimize Your Indoor Air Quality | GPS Air IAQ Solutions
- GPS Air | trademarks
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>