Hunter 19654 Dunshire Bell Clear Glass 1 Light 12 Inch Medium Pendant Instructions
- June 4, 2024
- Hunter
Table of Contents
Dunshire
Bell Clear Glass 1 Light 12 Inch Medium Pendant
Instructions Manual For Models:
19654
19655
19654 Dunshire Bell Clear Glass 1 Light 12 Inch Medium Pendant
Here are the tools you’ll need to complete your installation:
| | |
---|---|---|---
Ladder
|
Screwdriver
|
Pliers
|
Wire Strippers
1. Light Pendant
Fixture weight ±2 lbs: 7.1 lbs (3.22 kg)
Hardware Service Kit
Part #| Model|
Finish
KD80101834| 19654
19655| Noble Bronze
INSTALLATION INSTRUCTIONS
WARNING
- To avoid possible electrical shock, before installing your light fixture, disconnect the power by turning off the circuit breakers to the outlet box associated with the wall switch location.
- The lighting fixture must be grounded. If the ground wire for the installation site is not present, immediately STOP installation and consult a qualified electrician.
- All wiring must be in accordance with national and local electrical codes ANSI/NFPA 70. If you are unfamiliar with wiring or in doubt, consult a qualified electrician.
READ AND SAVE THESE INSTRUCTIONS
These instructions are provided for your safety. It is very important that
they are read carefully and completely before beginning the installation of
the lighting fixture.
PREPARING FOR INSTALLATION
Carefully remove all contents from the carton. Shut off the power at the circuit breaker and completely remove the old fixture from the ceiling, including the old mounting bracket. Remove the new mounting bracket assembly from the bag. One end of the threaded post (H) should be attached to the mounting bracket (A) with a hex nut (G) in place. The other end should be connected to the canopy loop (E). Unscrew the canopy loop ring (F) from the canopy loop (E). Depending on the placement of your junction box the position of the threaded post (H) may need to be adjusted to allow the canopy to be flush with the ceiling. Determine this by lifting mounting bracket (A) up to the junction box and placing canopy (D) over the canopy loop (E), so that it is flush with the ceiling. Adjust the position of the threaded post (H) on the mounting bracket (A) so that the canopy (D) covers at least half of the exterior threads on the canopy loop (E) while it is securely connected to the threaded post (H). The threaded post (H) can be adjusted by loosening the hex nut (G) to allow movement of the threaded post (H) on the mounting bracket (A). Once the ideal position of the threaded post (H) is determined, tighten up the hex nuts (G) onto the threaded post (H) just beneath the mounting bracket (A) to secure the threaded post in place.
ASSEMBLING THE FIXTURE
There are 4 12-inch rods (I), and 1 6-inch rod (J) included for each fixture.
Determine the correct number of rods needed for proper hanging height. To
lengthen the fixture, add additional rods. To shorten the fixture, trim the
wires to the desired length. Leave at least 8 to 10 inches of wire in addition
to the desired length and slide any excess rods off the fixture’s wiring to
discard. Keep in mind that you must use at least one rod to hang the fixture.
Thread the wires through the rods and pull the wires until taut before
connecting the rods together. Screw the rod onto the threaded post (K) on the
fixture. Pull the fixture wires through the canopy loop ring (F), top of the
canopy (D), and canopy loop (E). Screw the threaded post of the top rod to the
canopy loop (E). Have a helper support the fixture’s weight and attach the
mounting bracket (A) to the junction box by securely tightening the mounting
screws (B).
CONNECTING THE WIRES
Attach the fixture’s wires to the power supply wires from the junction box.
Connect black to black (Live); white to white (grounded);
grounding to grounding (green or copper). Twist the ends of the wire pairs
together. Then, twist on a wire connector. Make sure all twists are in the
same direction. Loop fixture’s ground wire around grounding screw (C) and
tighten. If there is no ground wire (green or copper) from the junction box,
contact a qualified electrician.
FINISHING THE INSTALLATION
Place the canopy (D) flush to the ceiling and slide the canopy loop ring (F)
up beneath the canopy. Tightly screw canopy loop ring (F) onto the canopy loop
(E) to properly secure the canopy (D) in place. Install light bulb (not
included) in accordance with the fixture’s specifications. Do not exceed the
recommended wattage. Your installation is now
completed. Turn on the power and test the fixture.
CLEANING TIPS
Treat the fixture gently! Regular cleaning will reduce the need for deep
cleaning. For regular cleaning, turn off the light and wipe down the fixture
with a clean lint-free cotton or microfiber cloth. Never spray cleaner
directly onto the fixture.
NOTICE
| |
Hunter Pro Tip:
---|---|---
In order to use a 12-in rod by itself, you must first remove the post from the
6-in rod and install it on one of the ends of the 12-in rod.| wist or tape
wire ends together to make it easier to pass them through the downloads.
Threaded posts may also be removed for easier wire access.
©2021 Hunter Fan Co.
ML195
r112221
Documents / Resources
|
Hunter 19654 Dunshire Bell Clear Glass 1 Light 12 Inch Medium
Pendant
[pdf] Instructions
19654, Dunshire Bell Clear Glass 1 Light 12 Inch Medium Pendant, 19654
Dunshire Bell Clear Glass 1 Light 12 Inch Medium Pendant, Bell Clear Glass 1
Light 12 Inch Medium Pendant, Clear Glass 1 Light 12 Inch Medium Pendant,
Glass 1 Light 12 Inch Medium Pendant, Light 12 Inch Medium Pendant, 12 Inch
Medium Pendant, Medium Pendant, Pendant
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>