drive 13067 Non-Tilt Overbed Tables Instruction Manual
- June 1, 2024
- Drive
Table of Contents
drive 13067 Non-Tilt Overbed Tables
Product Information
Specifications:
- Table Top: 1 piece
- Column Assembly: 1 piece
- Trip Lever: 1 piece
- Bolts & Nuts: 11 pieces
- Mounting Bracket: 1 piece
- Domed Phillips Head Bolts & Lock Washers: 12 sets
- Base: 1 piece
- Casters with Lock: 2 pieces
Product Usage Instructions
Assembly Instructions:
- Remove contents from packaging and lay Table Top (1) upside down on a flat surface with Mounting Bracket (5) facing upward.
- Stand the Column Assembly (2) upright ensuring Trip Rod (1155) is inside and Trip Lever (3) is inserted correctly.
- Insert the Column Assembly (2) into the tabletop Mounting Bracket (5) and secure it with bolts and nuts.
- Install bolts and locking washers through the holes in the Mounting Bracket (5) into the Column Assembly (2).
- Install Casters With Lock (8) and Non-Locking Casters (9) into the Base (7).
- Insert Bolt Sleeves (1100) into the Base (7) and secure with Bolts (12).
- Turn the table upright and stand on the casters.
- Replace Black Screw (1133) with Chrome Screw (1144) in the Column Assembly (2).
FAQ:
-
Q: Can I assemble the table without using all the provided parts?
A: It is recommended to use all provided parts during assembly to ensure stability and proper functioning of the table. -
Q: What should I do if I encounter difficulties during assembly?
A: If you face any challenges during assembly, refer back to the assembly instructions carefully or contact customer support for assistance.
Assembly Instructions
- Remove contents from packaging and lay Table Top (1) upside down on flat surface with Mounting Bracket (5) facing upward. See Fig. 2.
- Stand the Column Assembly (2) right side up as shown in Fig. 1. Ensure Trip Rod (15) is visible in the rectangular tube (as shown), but not protruding out of the top. If necessary, shake the Column Assembly (2) until the Trip Rod (15) drops into place inside the Column Assembly (2). Next, insert the Trip Lever (3), with rounded side facing up, into the Column Assembly (2) as shown, ensuring that the flat side of the Trip Lever (3) rests on the Trip Rod. (15).
- While holding the Trip Lever (3) securely in place on top of the Trip Rod (15), flip the Column Assembly (2) upside down and insert the Column Assembly (2) into the table-top Mounting Bracket (5) as shown in Fig. 2
- Align a horizontal hole in the table top Mounting Bracket (5) with a horizontal hole in Column Assembly (2) and hole through Trip Lever (3). Insert 4 x 20 Bolt (4) into the horizontal hole & secure Nut (4). Tighten with 10mm wrench. See Fig. 3
- Install two Domed Phillips Head bolts and lock washers (6) through the vertical holes in the Mounting Bracket (5) and into the threaded holes in Column Assembly (2) as shown in Fig. 4
- Install two Casters With Lock (8) into Base (7) which connects to Column Assembly (2). Install two Non-Locking Casters (9) into base opposite Column Assembly (2). See Fig. 5
- Install two Bolt Sleeves (10) into upside down Base (7) and then position two Bolts (12) through Bolt Plate (11) and into Bolt Sleeves (10). Position Base (7) over Column Assembly (2) and thread bolts into bottom of Column Assembly (2) and tighten using 16mm wrench. See Fig. 6
- Turn the table upright and stand on the casters.
- CAUTION: This step must be completed last to prevent damage to the spring-loaded mechanism. Remove the Black Screw (13) in the Column Assembly (2) collar labeled “Remove for Assembly” and replace it with the Chrome Screw (14) contained in the hardware package. Do not remove Chrome Screw labelled “Do Not Remove”. See Fig. 7 and Fig. 8.
WARNING
FOR SAFETY – DO NOT REMOVE BLACK SCREW (13) ON COLUMN ASSEMBLY (2) UNTIL THE
TABLE IS FULLY ASSEMBLED AND STANDING IN UPRIGHT POSITION. AFTER REMOVING
BLACK SCREW, REPLACE WITH CHROME SCREW (14) INCLUDED IN THE HARDWARE PACKAGE.
THE BOTTOM CHROME SCREW WITH THE “DO NOT REMOVE” LABEL SHOULD NEVER BE REMOVED
AS IT WILL DAMAGE THE UNIT AND VOID YOUR WARRANTY
Parts List
- Table Top
- Column Assembly
- Trip Lever
- 1/4 – 20 x 2 1/8” Bolt & Nut (1 each)
- Mounting Bracket (Top to Column Assembly)
- 1/4 – 12 x 1/4” Domed Phillips Head Bolt & Lock Washer (2each)
- Base
- Casters with Lock (2 each)
- Casters without Lock (2 each)
- Bolt Sleeves (2 each)
- Bolt Plate
- 3/8 – 15 x 2” Bolts (2 each)
- Black Screw
- Chrome Screw (to replace #13 black screw)
- Trip Rod 1/4” x 20 1/2” (inside Column Assembly)
Operating Instructions
- To raise top to the desired height, apply light pressure upward at any point under table.
- To lower, squeeze trip lever (3) up towards top and push down at the column to the desired height. Do not put pressure on the tabletop end that is opposite the column. Column assembly will lock upon release of the trip lever.
Assembly Precautions
This Overbed Table utilizes a high-tension spring-loaded mech-anism to raise
the table, DO NOT remove #13 Black Screw and replace it with #14 Chrome Screw
until the table is fully assembled.
DO NOT over-tighten bolts, or screws or use power tools when assembling this
product.
Important Warnings
Please follow all instructions and warnings to avoid hazardous situations that
can result in property damage and/or patient/resident/staff/caregiver injury
and/or death.
Inspect the product for damage and loose hardware before each use. DO NOT use
the product if it appears to be damaged or unstable and DO NOT modify the
product in any way.
Intended Use
This product is designed for use as a movable patient/resident tabletop
surface for reading, eating, or keeping small personal items such as glasses,
telephone, or books within easy reach.
This product is designed for indoor use ONLY within close proximity of skilled
caregivers. It is not designed to hold electrical items (such as televisions,
computer monitors, coffee pots, etc.) and should not be used near open flames
and excessive heat.
The maximum weight limitation for this product is 50 lbs (22 kg.); weight
should be evenly distributed over the tabletop surface while at the lowest
usable height to help maintain a stable condition.
DO NOT overload the product as that could result in breakage, as well as
damage to property and/or serious injury.
Use ONLY as directed for its intended use. This product should NOT be used: as
a sleep surface; as a walker or mobility aid to assist a person in walking,
sitting down or standing up; to prevent or brace a person’s fall; or to help
transport persons or items.
Lifetime Limited Warranty
- Your Drive branded product is warrantied to be free of defects in materials and workmanship for the lifetime of the product for the original consumer purchaser.
- This device was built to exacting standards and carefully inspected before shipment. This Lifetime Limited Warranty is an expression of our confidence in the materials and workmanship of our products and our assurance to the consumer of years of dependable service.
- This warranty does not cover device failure due to owner misuse or negligence, or normal wear and tear. The warranty does not extend to non-durable components, such as rubber accessories, casters, and grips, which are subject to normal wear and need periodic replacement.
- If you have a question about your Drive device or this warranty, please contact an authorized Drive dealer.
© 2014 Medical Depot, Inc. All rights reserved.
Drive is a trademark of Medical Depot, Inc.
Port Washington N.Y. 11050 USA Made in China
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>