Drive Medical 13008 Deluxe Tilt Top Overbed Table Instruction Manual
- June 1, 2024
- Drive Medical
Table of Contents
Drive Medical 13008 Deluxe Tilt Top Overbed Table Instruction Manual
Assembly Instructions
-
Remove contents from packaging and lay top board upside down on flat surface with Mounting Tube (5) facing upward. See Fig. 2
-
Take the Column Assembly (2) and place Trip Lever (3) on top of Trip Rod and secure with Bolt and Nut (4) **See Fig. 1
**
-
Remove Triangle Knob (16) and Spacer (17) and remove Inner tube (6) from Outer tube (18). See Fig. 3
-
Insert Outer tube (18) on Column Assembly through Mounting Tube (5) on table top. Then insert Inner tube (6) through Mounting Tube (5). See Fig. 4.
-
Replace Triangle Knob (16) and Spacer (17) and secure by tightening the knob.
-
Install two Casters With Lock (8) into Base (7) which connects to Column Assembly (2). Install two Non-Locking Casters (9) into base opposite Column Assembly (2). See Fig. 5.
-
Install two Bolt Sleeves (10) into upside down Base (7) and then position two Bolts (12) through Bolt Plate (11) and into Bolt Sleeves (10). Position Base (7) over Column Assembly (2) and thread bolts into bottom of Column Assembly (2) and tighten using 16mm wrench. **See Fig. 6.
**
- Turn the table upright and stand on casters.
- CAUTION: This step must be completed last to prevent damage to the spring loaded mechanism. Remove the Black Screw (13) in the Column Assembly (2) collar labeled “Remove for Assembly” and replace it with the Chrome Screw (14) contained in hardware package. Do not remove Chrome Screw labeled “Do Not Remove”. **See FIg. 7 and Fig. 8.
**
WARNING
FOR SAFETY – DO NOT REMOVE BLACK SCREW (13) ON COLUMN ASSEMBLY (2) UNTIL THE
TABLE IS FULLY ASSEMBLED AND STANDING IN UPRIGHT POSITION. AFTER REMOVING
BLACK SCREW, REPLACE WITH CHROME SCREW (14) INCLUDED IN HARDWARE PACKAGE.
THE BOTTOM CHROME SCREW WITH THE “DO NOT REMOVE” LABEL SHOULD NEVER BE
REMOVED AS IT WILL DAMAGE THE UNIT AND VOID YOUR WARRANTY
Parts List
- Table Top
- Column Assembly
- Trip Lever
- 1/4 – 20 x 2 1/8” Bolt & Nut (1 each)
- Mounting Tube (Top to Column Assembly)
- Inner Tube
- Base
- Casters with Lock (2 ea)
- Casters without Lock (2 ea)
- Bolt Sleeves (2 each)
- Bolt Plate
- 3/8 – 15 x 2” Bolts (2 each)
- Black Screw
- Chrome Screw (to replace #13 black screw)
- Trip Rod 1/4” x 20 1/2” (inside Column Assembly)
- Triangle Knob
- Spacer
- Outer Tube
Operating Instructions
- To raise top to desired height, apply light pressure upward at any point under table.
- To lower, squeeze trip lever (3) up towards top and push down at column to desired height. Do not put pressure on tabletop end that is opposite the column. Column assembly will lock upon release of trip lever.
- To tilt, turn Triangle Knob (16) counter-clockwise to loosen. Set to desired angle and then turn knob (16) clockwise to tighten.
Assembly Precautions
This Overbed Table utilizes a high-tension spring loaded mechanism to raise
the table, DO NOT remove #13 Black Screw and replace with #14 Chrome Screw
until table is fully assembled.
DO NOT over tighten bolts, screws or use power tools when assembling this
product.
Important Warnings
Please follow all instructions and warnings to avoid hazardous situations that
can result in property damage and/or patient/ resident/staff/caregiver injury
and/or death. Inspect the product for damage and loose hardware before each
use. DO NOT use the product if it appears to be damaged or unstable and DO NOT
modify the product in any way.
Intended Use
This product is designed for use as a movable patient/resident table top
surface for reading, eating, or keeping small personal items such as glasses,
telephone, or books within easy reach.
This product is designed for indoor use ONLY within close proximity of skilled
caregivers. It is not designed to hold electrical items (such as televisions,
computer monitors, coffee pots, etc.)and should not be used near open flames
and excessive heat.
Maximum weight limitation for this product is 50 lbs (22 kg.); weight should
be evenly distributed over the table top surface while at the lowest usable
height to help maintain a stable condition
Lifetime Limited Warranty
Your Drive branded product is warrantied to be free of defects in materials
and workmanship for the lifetime of the product for the original consumer
purchaser.
This device was built to exacting standards and carefully inspected prior to
shipment. This Lifetime Limited
Warranty is an expression of our confidence in the materials and workmanship
of our products and our assurance to the consumer of years of dependable
service.
This warranty does not cover device failure due to owner misuse or negligence,
or normal wear and tear. The warranty does not extend to non durable
components, such as rubber accessories, casters, and grips, which are subject
to normal wear and need periodic replacement.
If you have a question about your Drive device or this warranty, please
contact an authorized Drive dealer
SPECIAL NEEDS COMPUTERS
1-877-724-4922
©2014 Medical Depot, Inc. All rights reserved.
Drive is a trademark of Medical Depot, Inc.
Port Washington N.Y. 11050 USA Made in China
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>