PLT PremiumSpec Color Selectable Architectural LED Light Engine Instruction Manual

June 1, 2024
PLT

PLT PremiumSpec Color Selectable Architectural LED Light Engine Instruction Manual
PLT PremiumSpec Color Selectable Architectural LED Light
Engine

WARNING

  • Installation, service, and maintenance of luminaries should be performed by a qualified licensed electrician.
  • Please read these instructions to fully understand and safely use this product.

CAUTION

  • Check that all fixture connections have been properly made and the fixture is grounded to avoid potential electrical shock.
  • Designed for use in AC 120-277V, 50/60Hz, 1-10V dimming protected circuits.

NOTICE

  • Suitable for damp locations.
  • Access above ceiling required. Suitable for suspended ceilings.

LED Light Engines

40w
REES0326

80W
PLT-90327
LED Light Engines

Reflector Trims

6″ Round
**PLT-90328

8″ Round
PLT-90329

10” Round
PLT-90330**
Reflector Trims

Installation Instructions

Pre-Installation

  1. PLT-90326 & PLT-90327 light engines are designed for use with PLT-90328 to PLT-90330 trims.
  2.  Align the three pins located on the light engine with the slots atop the reflector trim.
  3. Turn clockwise until it is tightened.
    Installation Instructions

Installation

  1. Locate the desired location for the fixture and make a mark on the ceiling at that spot.

  2. Drill a hole in the ceiling according to the trim size (see Trim Size section in these instructions). (Figure 1)
    Installation Instructions

  3. If retrofitting an existing application, use the mounting frame from the existing fixture.
    Note: Top access is recommended.

  4. If mounting in new construction, install a mounting frame (purchased separately), making sure the frame can support the weight of the luminaire. Secure the frame within the ceiling plenum. Note: Top access is REQUIRED.

  5. For new construction, mount the four retaining clips on the mounting frame equidistant around the collar (Figure 2).
    Installation Instructions

  6. PLT-90326: The 40-watt driver contains two whips (Figure 3).
    Installation Instructions
    Plug the black, white, and red wires of the driver whip into the connection port inside the hole on the light engine (Figure 4).
    Installation Instructions

    Push the whip into the hole on the light engine until it engages. PLT-90327: The 80-watt driver contains two whips (Figure 3). Plug the black and red wires of the driver whip into the connection port inside the hole on the light engine. Push the whip into the hole on the light engine until it engages.

  7. Connect the driver whip with five-conductors to the junction box (supplied by others), connecting the black wire to the line, the white wire to the neutral, and the green wire to ground (Figure 5).
    Installation Instructions
    Green
    NOTE: Compatible with 0-10V dimmers. Connect the driver’s PURPLE (D+) wire to the dimmer’s Violet PURPLE (+) wire, and the driver’s PINK (D-) wire to the dimmer’s PINK (-) using UL listed wire nuts (supplied by others). Tuck all wires back in the junction and close the cover.

  8. Move the driver’s “Low/Medium/High” or “1000/670/450” wattage light output switch to your desired setting. If installing our CCT Selectable PLT-90326 offering, move the 3000K/3500K/4000K switch to your desired setting. (Figure 6 and Figure 7)
    Installation Instructions
    Installation Instructions

  9. Secure the driver to the ceiling with screws (supplied by others).

  10. Connect the safety cable (attached to the light engine) to a structural member within the ceiling.

  11.  Push the reflector and light engine into the ceiling cavity. The retaining clips attached to the mounting frame will keep the luminaire snug against the ceiling (Figure 8).
    Installation Instructions

  12. If retrofitting, attach the “Lamping Replacement Cautionary Label” in a visible location on the luminaire.

Trim Size

SKU Trim Type Recommended Hole Size
PLT-90328 6-inch Round 6.0” min to 6.7” max.
PLT-90329 8-inch Round 7.7″ min to 8.4” max.
PLT-90330 10-inch Round 10.0” min to 10.7” max

WARNING

  • Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
  • To reduce the risk of death, personal injury, or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards, read all warnings and instructions included with and on the fixture box and all fixture labels.
  • Proper grounding is required to ensure safety.
  • Power must be turned off at the breaker before installation or maintenance.
  • This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
  • Wear gloves and eye protection at all times while installing, servicing, or performing maintenance on the luminaire, and avoid direct eye exposure to the light source while it is on.
  • To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
  • Do not install damaged product. Inspect luminaire for damage that may have occurred during transit. If damaged, contact the manufacturer immediately.
  • These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, contact the manufacturer.