DIMENSIONS
E39
EX39
*Special Order, call 1-800-624-4488
NOTICE FOR USER
- Please turn off power before installation or maintenance.
- The input voltage of the fixture and lamps should match. Make sure wiring is insulated.
- Installation, service, and maintenance of luminaries should be performed by a qualified licensed electrician.
- Suitable for damp locations. Do not use with dimmers.
- Make sure to remove or bypass the ballast in the fixture before installing the lamp.
- Suitable for use in enclosed luminaires, min. Luminaire compartment dimensions: 420230230M
ADVANTAGE
- UL cUL certificate
- E39 or EX39 lamp base
- Big heat sink,NO fan
- Internal driver, input voltage AC120-277V 1-10V dimming .
- Wattage adjustable options are available, segmented wattage adjustable
- Meets 4KV surge immunity level
- Long lifespan and good heat dissipation
- Direct replacement for Metal Halide, easy installation
- Fits many different fixtures to replace traditional lamps
- Operating ambient temperature up to 50 degrees Celsius
- Rotatable, ensures light output is aimed directly out of the fixture
APPLICATION
- Replacement Lamps for Outdoor Pole/ Arm-mounted Area and Roadway Luminaires(UL Type B)
SPECIFICATIONS
PACKAGE
**OPTICAL| Input Power (Tolerance : ±10%)|
75W(54W63W/75W via switch)
---|---|---
Color Temperature| 3000K| 3500K| 4000K| 4500K| 5000K| 5700K| 6500K
Lumen (Tolerance : ±10%)-InLuminaires| ** 8550LM| 8640LM|
8729LM| 8819LM| 8909LM| 8998LM| 9088LM
Efficacy (Tolerance : ±3%)-InLuminaires| 110LM/W| 112LM/W|
113LM/W| 114LM/W| 115LM/W| 116LM/W| 117LM/W
CRI| >80
Color Consistency| <6 Steps (or <6 SDCM)
Diffuser Type| TYPEⅢ
Beam Angle(50%)(Tolerance : ±25%)| 115Degree
**ELECTRICAL| Input Voltage and Frequency|
120-277VAC 50/60Hz
PF (Tolerance : -3%)| ≥0.9
THD (Tolerance : +5%)| ≤20%
Flicker Percent| <100%
Driver Surge protection| L-N: 4kV
Dimmable| 0-10V dimming standard (through switch on the lamp)
Sensor Type| NO
Optional Accessory| NO
Equivalent| 150W CFL,250W MHL/HPS/HID
****MATERIALS| LED Brand| LUMILEDS
LED Type| SMD2835
LED QTY| 140PCS
Housing| PC + Aluminum
Housing Color| Any colour
Waterproof Rating| DAMP(IP64)
****OTHERS**| Operating Temperature| -40℃ TO 50℃
Storage Temperature| -40℃ TO 80℃
Operating Humidity| 20%-70% RH
Storage Humidity| 10%-75% RH
Warranty Time| 5 years
*Multiple CCT options available via Special Order. Call 1-800-624-4488.
PACKAGE
| Size| Qty / Carton| Net Weight / Carton| Gross Weight /
Carton
---|---|---|---|---
Inner box| 340160110 MM| 1PCS| 1.25KG| 1.45KG
Outer box| 660360245 MM| 8PCS| 10KG| 12.51 KG
Tolerance of Outer Carton Size: ±15 MM, Tolerance of Weight: ±10%.
LIGHT DISTRIBUTION TESTING PARAMETERS
Remark: The testing data comes from the product in luminaires.
Luminaire Property
Luminaire Manufacturer:
Luminaire Category:
Lamp Catalog:
Number of Lamps:
Luminous Length (mm):
Luminous Height (mm):
Current: 0.669 A
Power Factor: 0.964
Luminaire Description:
Lamp Description:
Lumens per Lamp:
Luminous Width (mm):
Voltage: 120.0 V
Power: 77.29 W
Photometric Results
IES Classification : Type II
Total Rated Lamp Lumens : 8549.9 Im
Efficiency: 100%
Upward Ratio: 0%
COro Intensity: 2504.13 cd
Pos of Max. Intensity: H157.5 V24
Luminous Intensity Distribution Curve
Longitudinal Classification: Very Short
Measurement Flux: 8549.9 Im
Downward Ratio: 100%
Luminaire Efficacy Rating (LER): 110.67
Max. Intensity: 4400.28 cd
Beam Angle(CO/C180,C90/C270,C45/C225,C135/315): 124.8, 99.0, 101.9, 96.7
The Average Illuminance Effective Figure
Flux Out : 847767m
The Average Illuminance Effective Figurefd
Problem | Solution |
---|---|
Flickering light | Turn off the power, then turn on again after 3 minutes. |
Ifthe light continues to flicker, call a licensed electrician.
Light is not coming on| Check the electrical connection.