TECHNICAL DATA
Compact Transfer Pump| M18 BTP
---|---
Production code| 4742 30 01 …

… 000001-999999

Battery voltage| 18 V
Protection class| IPX4
Flow rate max.| 30,3 l/min
Head height max.| 23 m
Lift height max.| 5,5 m
Water temperature max.| 60 °C
Air temperature max.| 40 °C
Pump fitting (Hose)| 13 mm (1/2“) NPT male to 19 mm (3/4“) BSPT male
19 mm (3/4“) BSPT female
Continuous runtime max.| 1 h
Weight without battery| 3,4 kg
Weight according EPTA-Procedure 01/2014 (Li-Ion 2,0 Ah … 12,0 Ah)| 4,0 kg…, 5,1 kg
Recommended battery types| M18B…M18HB
Recommended charger| M12-18…; M1418C6

WARNING Read all safety warnings, instructions, illustrations and specifications provided with this power tool. Failure to follow all instructions listed below may result in electric shock, fire and/or serious injury. Save all warnings and instructions for future reference.

SAFETY INSTRUCTIONS FOR PUMPS

  • Do not place pump under water or in wet areas. Place pump in dry locations only.
  • Caution! Risk of electric shock Do NOT connect conduit to pump.
  • Do not pump flammable or explosive fluids such as gasoline, fuel oil, kerosene, etc. Do not use the device in rooms with a potentially explosive atmosphere.
  • Do not pump water with a termperature over 60 °C (140 °F). Do not pump sand, particulate, or large debris. Damage to the pump will occur.
  • Do not allow pump to run dry for more than 10 seconds. Turn off pump quickly when job is complete. Always remove battery pack before attempting to install or service the pump.
  • Do not allow this pump to operate unattended. Failure to follow this warning could result in personal injury and/or death.
  • Always remove battery pack before attempting to install or service  the pump. Never handle pump with wet hands or when standing on a wet or damp surface or in water. Fatal electrical shock could occur.
  • Secure the discharge hose before starting the pump. An unsecured discharge hose may whip. Personal injury and/or death could result.
  • Do not use the pump if the switch does not turn it on and off. Any pump that cannot be controlled with the switch is dangerous and must be repaired.
  • Do not operate pump in explosive atmospheres, such as in the presence of flammable liquids, gases, or dust. Motors create sparks which will ignite the dust of fumes.
  • Dress properly. Do not wear loose clothing or jewellery. Keep your hair, clothing and gloves away from moving parts. Wear protective hair covering to contain long hair. Loose clothes, jewelry, or long hair could be caught in moving parts.
  • Do not overreach. Keep proper footing and balance at all times. Proper footing and balance enables better control in unexpected situations.

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.Children shall not play with the appliance.

Cleaning and user maintenance shall not be made by children without supervision.This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

Children should be supervised to ensure that they do not play with the appliance.

Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

DESCRIPTION

DESCRIPTION

  1. Outlet
  2. Direction of flow indicator
  3. Handle
  4. Battery compartment button
  5. Battery compartment
  6. On/Off button
  7. Inlet

ADDITIONAL SAFETY AND WORKING INSTRUCTIONS

  • Not for potable water or other potable liquids.
  • Always remove battery pack from the pump before making any adjustments, changing accesories, or storing appliance. Such preventive safety measures reduce the risk of starting the appliance accidentally.
  • Keep handles and grasping surfaces dry, clean and free from oil and grease. Slippery handles and grasping surface do not allow for safe handling and control of the tool in unexpected situations.
  • Keep bystanders, children, and visitors away while operating pump. Distractions will result in mistakes.
  • Stay alert, watch what you are doing and use common sense when operating this pump. Do not attempt to operate this pump while your are tired or under the influence of drugs, alcohol or medication. A moment of inattention may result in serious personal injury.
  • Use safety equipment. Always wear eye protection. Dust mask, non-skid safety shoes and hard hat must be used for appropiate conditions.
  • Do not let familiarity gained from frequent use of tools allow you to become complacent and ignore tool safety principles. A careless action can cause severe injury within a fraction of a second.
  • Do not pump water from a creek, pond, or source where foreign objects may be sucked into the pump. Solids may enter the inlet hose.
  • Keep work area clean and well lit. Cluttered or dark areas invite accidents.
  • Indoor use only.
  • Use hoses with 19 mm (3/4”) BSPT brass female fitting.
  • A heavy duty hose should be used for the inlet hose to prevent the hose from collapsing. For best results, use a short length, large diameter hose, such as a 183 cm (6’) long, 19 mm (3/4”) inner diameter garden hose. Longer or thinner hoses may reduce performance and flow rate.
  • A regular garden hose may be used as an outlet hose

SPECIFIED CONDITIONS OF USE

This pump is designed for applications such as emptying water heaters, tanks, etc. The pump is not waterproof or weatherproof and is not intended to be used outdoors or inside showers, saunas or other potentially wet locations.

This pump has been evaluated for use with clear water only. It is not designated to handle salt water, brine, laundry discharge, or any other application which may contain caustic chemicals and/or foreign material. This pump is not suitable for use with aquatic life. Do not use this product in any other way as stated for normal use

BATTERIES

Battery packs which have not been used for some time should be recharged before use.

Temperatures in excess of 50°C (122°F) reduce the performance of the battery pack. Avoid extended exposure to heat or sunshine (risk of overheating).

The contacts of chargers and battery packs must be kept clean.

For an optimum life-time, the battery packs have to be fully charged, after use. Battery packs which have not been used for some time should be recharged before use. To obtain the longest possible battery life remove the battery pack from the charger once it is fully charged. For battery pack storage longer than 30 days: Store the battery pack where the temperature is below 27°C and away from moisture Store the battery packs in a 30% – 50% charged condition, Every six months of storage, charge the pack as normal.

Do not dispose of used battery packs in the household refuse or by burning them. Milwaukee Distributors offer to retrieve old batteries to protect our environment. Do not store the battery pack together with metal objects (short circuit risk).

Use only System M18 chargers for charging System M18 battery packs. Do not use battery packs from other systems.

Never break open battery packs and chargers and store only in dry rooms. Keep dry at all times.

Battery acid may leak from damaged batteries under extreme load or extreme temperatures. In case of contact with battery acid wash it off immediately with soap and water. In case of eye contact rinse thoroughly for at least 10 minutes and immediately seek medical attention.

No metal parts must be allowed to enter the battery section of the charger (short circuit risk).

BATTERY PACK PROTECTION

In extremely high torque, binding, stalling and short circuit situations that cause high current draw, the tool will stop for about 2 seconds and then the tool will turn OFF.

To reset, release the trigger.

Under extreme circumstances, the internal temperatur of the battery could become to high. If this happens, the battery will shut down.

Place the battery on the charger to charge and reset it.

TRANSPORTING LITHIUM BATTERIES

Lithium-ion batteries are subject to the Dangerous Goods Legislation requirements.

Transportation of those batteries has to be done in accordance with local, national and international provisions and regulations.

The user can transport the batteries by road without further requirements.

Commercial transport of Lithium-Ion batteries by third parties is subject to Dangerous Goods regulations. Transport preparation and transport are exclusively to be carried out by appropriately trained persons and the process has to be accompanied by corresponding experts.

When transporting batteries::

Ensure that battery contact terminals are protected and insulated  to prevent short circuit. Ensure that battery pack is secured againstmovement within packaging. Do not transport batteries that are cracked or leak. Check with forwarding company for further advice

MAINTENANCE

Maintain pump and accessories. Check for misalignment or binding of moving parts, breakage of parts and any other condition that may affect the pump‘s operation. If damaged, have the pump repaired before use. Accidents can be caused by a poorly maintained pump.

  • Remove the battery pack before starting any work on the appliance. Release all pressure within the system before servicing any component.
  • Drain all liquids from system before servicing.
  • Periodically inspect pump and system components, checking for weak and/or worn hoses. Check impeller for wear or blockage. Ensure all connections are secure.
  • When servicing a pump, use only identical replacement parts. Follow instructions in the Maintenance section of this manual. Use of unauthorized parts or failure to follow maintenance instructions may create a risk of electrical shock or injury and may void the warranty.
  • Do not modify or attempt to repair the pump or the battery pack except as indicated in the instructions for use and care.
  • Cleaning and user maintenance shall not be made by children without supervision.

Only use the appliance if it is in perfect condition.

Repairs should only be carried out by qualified persons using original spare parts otherwise this may result in considerable danger to the user.

Clean tool and guarding system with dry cloth.

Certain cleaning agents and solvents are harmful to plastics and other insulated parts.

Regular maintenance and cleaning provide for a long service life and safe handling.

Compliance with the specified service work and service intervals is mandatory.

Only carry out maintenance work described in the operating instructions.

Use only Milwaukee accessories and Milwaukee spare parts. Should components need to be replaced which have not been described, please contact one of our Milwaukee service agents (see our list of guarantee/service addresses).

If needed, an exploded view of the tool can be ordered. Please state the Article No. as well as the machine type printed on the label and order the drawing at your local service agents or directly at: Techtronic Industries GmbH, Max-Eyth-Straße 10, 71364 Winnenden, Germany.

TROUBLESHOOTING

PROBLEM CAUSE CORRECTION
Pump will not run. Impeller blockage. See „Impeller Replacement/ Clearing”
Flow rate is too low. Inlet/Outlet line is

clogged or damaged.
Inlet connection is not
airtight.| Replace Inlet/ Outlet line. Check
lines for blockages, kinks or bends.
Clear blockages.
| Impeller cover is not secured tightly.
Impeller worn out.| Tighten inlet connection, adding teflon tape or a gasket if necessary.
 |  | Hand tighten four (4) cover screws.
|  | See „Impeller Replacement/ Clearing“
Pump shutdown.| Dry pump shutdown.
Locked impeller.
Battery installed when
pump turned on.| Correct situation, then turn tool off, then back on to reset.
Over temperature shutdown| Blocked outlet line.
Outlet line too high.
Outlet line too long.
Pump ON for too long.| Allow pump to cool.
Correct situation, then turn tool off, then back on to reset.

SYMBOLS

CAUTION! WARNING! DANGER!

Please read the instructions carefully before starting the machine.

Wear ear protectors!

Always wear goggles when using the machine.

Not for flammable or caustic chemical Liquids.

  Max. Temperature of the Liquid to be transfered must not exceed 60 °C (140 °F).

Caution! Not too strong and not tighten with pliers.

Not frost-resitant

Max. continous runtime 1 h.

Keep bystanders, children, and visitors away while operating pump.

This tool is only suitable for indoor use. Never expose tool to rain.

Remove the battery pack before starting any work on the appliance.

Spare Part – Not included in standard equipment, available as a spare part.

Do not dispose electric tools, batteries/rechargeable batteries together with household waste material. Electric tools and batteries that have reached the end of their life must be collected separately and returned to an environmentally compatible recycling facility. Check with your local authority or retailer for recycling advice and collection point.

V Voltage

 Direct Current

European Conformity Mark

  British Conformity Mark

Ukraine Conformity Mark

  EurAsian Conformity Mark

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals