IMMERGAS 3.029467 Victrix Omnia Wall-Hung Connection Group Kit Instructions
- June 1, 2024
- IMMERGAS
Table of Contents
**IMMERGAS 3.029467 Victrix Omnia Wall-Hung Connection Group Kit Instructions
**
GENERAL WARNINGS.
All Immergas products are protected with suitable transport packaging.
The material must be stored in a dry place protected from the weather.
This instruction manual provides technical information for installing the
Immergas kit. As for the other issues related to kit installation (e.g. safety
in the workplace, environmental protection, accident prevention), it is
necessary to comply with the provisions specified in the regulations in force
and with the principles of good practice.
Improper installation or assembly of the Immergas appliance and/or components,
accessories, kits and devices can cause unexpected problems for people,
animals and objects. Read the instructions provided with the product carefully
to ensure proper installation.
Installation and maintenance must be performed in compliance with the regulations in force, according to the manufacturer’s instructions and by professionally qualified staff, meaning staff with specific technical skills in the plant sector, as envisioned by the law.
The Kit enables boiler connection for Victrix Omnia condensing boiler.
KIT INSTALLATION.
Mount the connection unit as shown in fig. 1, taking care to correctly
position the required seals.
N.B.: once assembly is complete, proceed with gas and water circuit
resistance tests.
Kit composition
Ref.| Description| Quantity
1| CU D.18 DIN flow connection pipe| 1
2| 24 x 16 x 2 flat gasket| 4
3| 18 x 10 x 2 flat gasket| 2
4| CU D.14 hot water outlet connection pipe| 1
5| G 3/4″Vabco fitting| 2
6| G 3/4″Squared gas cock| 1
7| D.18 Cupper bar hold| 1
8| CU D.14 cold water inlet connection pipe| 1
9| CU D.18 DIN return connection pipe| 1
10| 3/4″ F brass nut| 2
11| 1/2 F brass nut| 2
12| 1/2″ M ball valve| 1
13| G 1/2″ Vabco fitting| 1
Key:
M – System flow
AC – Domestic hot water outlet
G – Gas supply 3/4″
AF – Domestic cold water inlet
R – System return 3/4″