ideal lux AP2 Gioconda Wall Lamp Instruction Manual

June 1, 2024
ideal lux

ideal lux AP2 Gioconda Wall Lamp

Product Specifications:

  • Model: Gioconda AP2
  • Power: E14 max 2 x 40W
  • Voltage: 220-240V, 50/60Hz
  • Color Options: ARGENTO, ORO
  • Dimensions:
    • Height: 425mm
    • Width: 310mm
    • Depth: 215mm
  • Manufacturer: IDEAL LUX s.r.l.
  • Manufactured in Italy
  • Website: www.ideal-lux.com

Product Usage Instructions

Installation :
The lighting fitting should be installed by a qualified electrician following the assembly instructions provided in numerical progression.

Safety Instructions:

  1. Always ensure the power supply is disconnected before installation or maintenance.
  2. Avoid looking directly at the light source.
  3. Use appropriate mounting accessories and comply with safety regulations.
  4. Do not disassemble the LED light source.
  5. If the lamp does not turn on, replace the fuse.
  6. Ensure proper grounding according to safety class requirements.

Cleaning and Maintenance:
Regularly clean the fixture with a soft, dry cloth. Avoid using harsh chemicals or abrasive materials that may damage the finish.

Replacing Light Source:
If the LED light source needs replacement, contact the manufacturer or a qualified electrician for assistance.

Frequently Asked Questions (FAQ):

  • Q: Can I replace the LED light source myself?
    A: It is recommended to contact the manufacturer or a qualified electrician for LED light source replacement to ensure safety and proper functioning.

  • Q: What should I do if the lamp does not turn on?
    A: Check and replace the fuse if necessary. If the issue persists, consult with a qualified electrician for further assistance.

  • Q: Is grounding mandatory for this product?
    A: Yes, grounding is mandatory to ensure electrical safety as per the specified safety classes.

Gioconda AP2

  • Wall lamp
  • E14 max 2 x 40W / 220~240V 50/60Hz
    • 8021696044910 ARGENTO
    • 8021696060491 ORO ideal-lux-AP2-Gioconda-Wall-Lamp-fig- \(3\)

ASSEMBLY INSTRUCTIONS

FOLLOW THE ASSEMBLY INSTRUCTIONS BY READING THE NUMERICAL PROGRESSION
THE LIGHTING FITTING SHOULD BE INSTALLED BY A QUALIFIED ELECTRICIAN

ideal-lux-AP2-Gioconda-Wall-Lamp-fig- \(4\)

ideal-lux-AP2-Gioconda-Wall-Lamp-fig- \(5\)

SAFETY INSTRUCTIONS

  1. This fitting is produced and tested in accordance with the strictest European safety standards EN 60.598-1).
  2. This fitting cannot be disposed of as household waste. For disposal information ask the local authorities about how to collect it.
  3. As indicated by specific regulations, the lighting fitting should be installed by a qualified electrician.
  4. If the external wire is damaged it has to be replaced exclusively by the manufacturer, distributor or by a qualified electrician.
  5. Always isolate power before commencing installation, maintenance or repair.
  6. The luminaire contains certain parts which can be very hot.
  7. Each material requires specific mounting accessories. Use screws and wall plugs suitable for the material to which they are fastened. Those included may be unsuitable.
  8. Always tighten the screws firmly to avoid contact problems.
  9. This fitting should only be installed indoors.
  10. Luminaires not suitable for recessed on normally flammable surfaces.
  11. Luminaire not suitable for direct mounting on normal flammable surfaces.
  12. This fitting is only suitable for fixing to the ceiling.
  13. This fitting is only suitable for fixing to the wall.
  14. The weight of the lamp has to be supported by the chain. Adjust the length of the electric wire so that it is longer than the chain.
  15. Only use lamps which do not exceed the maximum specified wattage.
  16. Always observe the minimum distance between the lamp and the surface being lit, as shown in the icon. The lamp can cause a fire if the minimum distance is not observed.
  17. Auto-protected bulb. Only use bulbs marked with this symbol. Halogen bulbs get very hot. Wait until they cool down before replacing.
  18. Cracked or broken safety glass has to be replaced immediately. Use only manufacturer approved parts complying with regulations.ideal-lux-AP2-Gioconda-Wall-Lamp-fig- \(6\)
  19. Light source with not-substitutable light emitting diode (LED). Do not disassemble the product since the diodes can damage the eyes. Do not immerse in water. Wipe with a damp cloth. Do not use solvents or strong detergents.
  20. This fitting is equipped with a fuse. If the lamp is out of order, replace the internal fuse.
  21. Class I Electrical safety guaranteed by the main insulation and an additional protective conductor (earthing) connected with the metal frame of the lamp. Earthing is obligatory.
  22. Class Il Electrical safety guaranteed by the main insulation and a double or reinforced insulation. Earthing not necessary.
  23. Class III Electrical safety guaranteed by very low power supply (less than 50 Volt). Earthing excluded.
  24. Not protected.
  25. Protected against solid objects greater than 50 mm.
  26. Protected against solid objects greater than 12 mm.
  27. Protected against solid objects greater than 2,5 mm.
  28. Protected against solid objects greater than 1mm.
  29. Dust protected.
  30. Totally protected against dust infiltration.
  31. Not protected.
  32. Protected against vertically falling water drops.
  33. Protected against water drops falling with a maximum angle of 15° to the vertical axis.
  34. Protected against rain. 35. Protected against splashing water.
  35. Protected against water jets.
  36. Protected against strong water jets.ideal-lux-AP2-Gioconda-Wall-Lamp-fig- \(7\)
  37. Protected against temporary immersion.
  38. Protected against prolonged immersion.
  39. Luminaire not suitable for covering with thermally insulating material.
  40. Caution, risk of electric shock.
  41. Do not stare at the operating light source.

ideal-lux-AP2-Gioconda-Wall-Lamp-fig- \(8\)

IDEAL LUX s.r.l.
Via Taglio Destro 32
30035 Mirano (VE) Italy
www.ideal-lux.com
IDEAL LUX Warehouse
Via delle Industrie, 8/D
30036 Santa Maria di Sala (Venezia) 8.00 – 12.00 / 13.30 – 17.00

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals