DOMETIC GP-ISW-R Pure Sine Wave Inverter Remote User Manual

June 5, 2024
Dometic

DOMETIC GP-ISW-R Pure Sine Wave Inverter Remote

FEATURES

The GP-ISW-R remote allows the switching on and off of any GP-ISW inverter from a remote location. The LED display indicates the following:

  • Battery bank voltage display
  • Output power display
  •  Error condition indicator (High Battery, Low Battery, Over Temperature, Over Load conditions)
  • Action condition indicator (INV, POWER SAVING, GRID)

SPECIFICATIONS

SPECIFICATION ITEM GP-ISW-R-12/24
Input Voltage 10.5 ~ 66VDC
Operating Temperature Range 0 ~ 40°C
Storage Temperature Range -30°C ~ 70°C
Standby Current Draw < 80mA
Compatible Inverters GP-ISW700/1000/1500/2000/3000/4000

INTRODUCTION

FRONT PANEL INTRODUCTIONDOMETIC-GP-ISW-R-Pure-Sine-Wave-Inverter-
Remote-4
Note: the 24 volt inverter remote’s Battery volt-age indicator reads “20, 22, 24, 26, 28, 30.”

  1. Power ON/OFF button

    • Power ON/OFF button turns the inverter on or off.
  2. Output power indicator

    • Output power indicator shows the power draw from the inverter by the load. Ideally, the output power indicator should remain in the green & orange area of the bar chart. If the output power indicator is up to the red area, the OLP LED will flash and the inverter will shut down.
  3. Battery voltage indicator

    • The battery voltage indicator will move up and down as the battery voltage changes. Ideally, the voltage should remain in the green area of the bar chart.
      If the voltage goes into the red area at the top and bottom of the bar chart, the inverter may shut down.
  4. Other indicators

    • OVP (Over voltage protection):
    • This indicates that the inverter will shut down because its input voltage is above the voltage limit.
    • UVP (Under voltage protection):
    • This indicates that the inverter will shut down because its input voltage is below the voltage minimum.
    • OLP (Overload protection indicator):
    • Indicates the inverter will shut down due to a short circuit or overload protection.
    •  OTP (Over temperature protection indicator):
    • Indicates the inverter will shut down due to over-temperature protection. Once the inverter cools down, the indicator will turn off automatically.
    •  INV indicator:
    • Indicates the inverter is ready.
    • PWR. SAV. indicator:
    • Power-saving functions are described below:
      LED| MEANING| INVERTER OUTPUT
      ---|---|---
      Solid| Ready| ON
      Flashing| Active| OFF
      Off| Inactive|
    • GRID indicator:
      Indicates the AC Grid is connected to the inverter (only functional when connecting inverter series with Transfer Relay).

INTRODUCTION

REAR PANEL INTRODUCTIONDOMETIC-GP-ISW-R-Pure-Sine-Wave-Inverter-
Remote-1

  1. AUX port
    Note: the AUX port is only used in work trucks.
    The connector (shown above) attached to AUX wire (AWG 14 or 16) must be connected with a 12V / 0.5A fuse.

    •  Ignition Lockout function:
      Turns OFF the inverter when the auxiliary input wiring is connected to the ACC with 12 volts.

    • Return Override function:
      Turns ON the inverter when the auxiliary input wiring is connected to the reversed gear shift with 12 volts.

  2. JP1
    The JP1 is to set either the Return Override function or the Ignition Lockout function.

    • JP1 jumper “Short” – Return Override function:
    • Turns ON the inverter when the auxiliary input wiring is connected to the reversed gear shift with 12 volts.
    • JP1 jumper “Open” – Ignition Lockout function:
    • Turns OFF the inverter when the auxiliary input wiring is connected to the ACC with 12 volts.
    • The connector which is connected to AUX power must be used with a 12V / 0.5A fuse.
      TRIGGERED SIGNAL|

JP1

|

INVERTER STATUS

---|---|---
AUX
1| Open| OFF
0| Open| ON
1| Short| ON
0| Short| OFF

Note: default mode is Open.

  1. PHONE JACK CONNECTOR
    1. Before connecting, make sure to switch the inverter to REMOTE mode .DOMETIC-GP-ISW-R-Pure-Sine-Wave-Inverter-Remote-3
    WARNING! DO NOT use a standard telephone cable.

© 2021 Go Power!
Worldwide Technical Support and Product Information gpelectric.com Go Power! | Dometic
201-710 Redbrick Street Victoria, BC, V8T 5J3
Tel: 1.866.247.6527
80325_MANUAL_ISW-R_RevB

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals