ideal lux PL1 D40 Mapa Bianco Ceiling Lamp Instruction Manual

June 1, 2024
ideal lux

ideal-lux-logo

ideal lux PL1 D40 Mapa Bianco Ceiling Lamp

ideal-lux-PL1-D40-Mapa-Bianco-Ceiling-Lamp-product-
image

Product Specifications:

  • Model: Mapa Bianco PL1 D40
  • Socket Type: E27
  • Maximum Wattage: 1 x 60W
  • Voltage: 220-240V, 50/60Hz
  • Barcode: 8021696059839
  • Color: BIANCO

Product Usage Instructions

Installation:
The lighting fitting should be installed by a qualified electrician following the assembly instructions provided in the manual.

Safety Instructions:

  • Always disconnect the power supply before installation or maintenance.
  • Avoid looking directly at the light source.
  • Ensure the fitting is compliant with safety standards.
  • For damaged external electrical cables, replacement should be done by the manufacturer, retailer, or qualified electrician.
  • Use appropriate fixing accessories and comply with regulations.
  • Do not disassemble the LED light source.
  • If the lamp does not turn on, replace the fuse.
  • Ensure proper grounding as per safety class requirements.

Safety Classes:

  • Class I: Main insulation with grounding connection.
  • Class II: Double insulation or reinforced insulation without grounding.
  • Class III: Safety ensured by low voltage (below 50 Volts).

Protection Ratings:

  • IP0… to IP6…: Protection against solid objects and dust ingress.
  • IPX1… to IPX8: Varying levels of protection against solid objects and moisture.

Frequently Asked Questions (FAQ):

  • Q: Can I replace the LED light source in the fixture?
    A: No, the LED light source is non-replaceable. Do not disassemble it.

  • Q: What should I do if the lamp does not turn on?
    A: Check and replace the fuse if needed. If the issue persists, consult a professional electrician.

  • Q: Is grounding mandatory for this lighting fixture?

  • A: Yes, grounding is mandatory to ensure electrical safety as per the specified safety classes.

IDEAL LUX s.r.l.

  • www.ideal-lux.com
  • IDEAL LUX Warehouse
  • Via delle Industrie, 8/D
  • 30036 Santa Maria di Sala (Venezia) 8.00 – 12.00 / 13.30 – 17.00

Mapa Bianco PL1 D40

  • Ceiling lamp
  • E27 max 1 x 60W / 220~240V 50/60Hz

ideal-lux-PL1-D40-Mapa-Bianco-Ceiling-Lamp- \(4\)

FOLLOW THE ASSEMBLY INSTRUCTIONS BY READING THE NUMERICAL PROGRESSION

THE LIGHTING FITTING SHOULD BE INSTALLED BY A QUALIFIED ELECTRICIANideal-
lux-PL1-D40-Mapa-Bianco-Ceiling-Lamp- \(5\) ideal-lux-PL1-D40-Mapa-Bianco-Ceiling-Lamp- \(6\) ideal-lux-PL1-D40-Mapa-Bianco-Ceiling-Lamp- \(7\) ideal-lux-PL1-D40-Mapa-Bianco-Ceiling-Lamp- \(8\)

SAFETY INSTRUCTIONS

  1. This fitting is produced and tested in accordance with the strictest European safety standards (EN 60.598-1).
  2. This fitting cannot be disposed of as household waste. For disposal information ask the local authorities about how to collect it.
  3. As indicated by specific regulations, the lighting fitting should be installed by a qualified electrician.
  4. If the external wire is damaged it has to be replaced exclusively by the manufacturer, distributor or by a qualified electrician.
  5. Always isolate power before commencing installation, maintenance or repair.
  6. The luminaire contains certain parts which can be very hot.
  7. Each material requires specific mounting accessories. Use screws and wall plugs suitable for the material to which they are fastened. Those included may be unsuitable.
  8. Always tighten the screws firmly to avoid contact problems.
  9. This fitting should only be installed indoors.
  10. Luminaires not suitable for recessed on normally flammable surfaces.
  11. Luminaire not suitable for direct mounting on normal flammable surfaces.
  12. This fitting is only suitable for fixing to the ceiling.
  13. This fitting is only suitable for fixing to the wall.
  14. The weight of the lamp has to be supported by the chain. Adjust the length of the electric wire so that it is longer than the chain.
  15. Only use lamps which do not exceed the maximum specified wattage.
  16.  Always observe the minimum distance between the lamp and the surface being lit, as shown in the icon. The lamp can cause a fire if the minimum distance is not observed.
  17. Auto-protected bulb. Only use bulbs marked with this symbol. Halogen bulbs get very hot. Wait until they cool down before replacing.
  18. Cracked or broken safety glass has to be replaced immediately. Use only manufcturer approved parts complying with regulations.
  19. Light source with not-substitutable light emitting diode (LED). Do not disassemble the product since the diodes can damage the eyes. Do not immerse in water. Wipe with a damp cloth.
  20. Do not use solvents or strong detergents.
  21. This fitting is equipped with a fuse. If the lamp is out of order, replace the internal fuse.
  22. Class I Electrical safety guaranteed by the main insulation and an additional protective conductor (earthing) connected with the metal frame of the lamp. Earthing is obligatory.
  23. Class Il Electrical safety guaranteed by the main insulation and a double or reinforced insulation. Earthing not necessary.  Class Ill Electrical safety guaranteed by very low power supply (less than 50 Volt). Earthing excluded.
  24.  Not protected.
  25. Protected against solid objects greater than 50 mm.
  26. Protected against solid objects greater than 12 mm.
  27. Protected against solid objects greater than 2,5 mm
  28. Protected against solid objects greater than 1mm.
  29. Dust protected.
  30. Totally protected against dust infiltration.
  31. Not protected.
  32.  Protected against vertically falling water drops.
  33. Protected against water drops falling with a maximum angle of 15° to the vertical axis.
  34. . Protected against rain
  35. Protected against splashing water
  36. Protected against water jets.
  37. Protected against strong water jets.
  38. Protected against temporary immersion
  39. Protected against prolonged immersion.
  40. Luminaire not suitable for covering with thermally insulating material.
  41. Caution, risk of electric shock.
  42. Do not stare at the operating light source

ideal-lux-PL1-D40-Mapa-Bianco-Ceiling-Lamp- \(8\) ideal-lux-PL1-D40-Mapa-Bianco-Ceiling-Lamp- \(10\)

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals