MEAN WELL ERP-350 Series 350W Single Output Switching Power Supply Owner’s Manual
- June 1, 2024
- MEAN WELL
Table of Contents
MEAN WELL ERP-350 Series 350W Single Output Switching Power Supply
Product Information
Product Specifications
MODEL| DC VOLTAGE| RATED CURRENT| CURRENT RANGE RATED POWER| RIPPLE & NOISE
(max.)
---|---|---|---|---
ERP-350-12| 12V| 26.7A| 0 ~ 26.7A 320.4W| 150mVp-p
ERP-350-24| 24V| 14.6A| 0 ~ 14.6A 350.4W| 150mVp-p
ERP-350-36| 36V| 9.7A| 0 ~ 9.7A 349.2W| 240mVp-p
ERP-350-48| 48V| 7.3A| 0 ~ 7.3A 350.4W| 240mVp-p
Frequently Asked Questions
- Q: Can I use ERP-350 series power supply for outdoor applications?
- A: The ERP-350 series is designed for indoor use only and should not be exposed to outdoor elements to ensure proper functioning and safety.
- Q: What is the maximum ripple and noise level for ERP-350-36 model?
- A: The maximum ripple and noise level for the ERP-350-36 model is 240mVp-p, as indicated in the specifications.
- Q: How do I ensure proper ventilation for the ERP-350 series power supply?
- A: To maintain optimal performance and prevent overheating, ensure that the power supply unit has proper ventilation by keeping it in a well-ventilated area with sufficient airflow.
Features
- AC input 180~264VAC
- Withstand 300 VAC surge input for 5 seconds
- Design against rain splash
- Protections: Short circuit / Overload / Over voltage/ Over temperature
- Cooling by free air convection
- LED indicator for power on
- Low cost,high reliability
- 100% full load burn-in test
- 3 years warranty
Applications
- LED strip lighting
- LED channel letters
- LED display
GTIN CODE
- MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
ERP-350 series is a 350W single output enclosed type AC/DC power supply. It adopts an aluminum case and the interior is semi-potted, protecting the internal electronic components from rain splash and dust. With the complete protection functions, ERP-350 is suitable for the applications such as outdoor LED channel letters, billboard, commercial display, etc.
Model Encoding
SPECIFICATION
MODEL| | ERP-350-12| ERP-350-24| ERP-350-36|
ERP-350-48
---|---|---|---|---|---
OUTPUT
| DC VOLTAGE| 12V| 24V| 36V| 48V
RATED CURRENT| 26.7A| 14.6A| 9.7A| 7.3A
CURRENT RANGE| 0 ~ 26.7A| 0 ~ 14.6A| 0 ~ 9.7A| 0 ~ 7.3A
RATED POWER| 320.4W| 350.4W| 349.2W| 350.4W
RIPPLE & NOISE (max.) **Note.2| 150mVp-p| 150mVp-p| 240mVp-p| 240mVp-p
VOLTAGE ADJ. RANGE| 10.8 ~ 13.2V| 21.6 ~ 26.4V| 32.4 ~ 39.6V| 43.2 ~
52.8V
VOLTAGE TOLERANCE Note.3| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 1500ms, 200ms/230VAC
HOLD UP TIME (Typ.)**| 20ms/230VAC
INPUT
| VOLTAGE RANGE| 180 ~ 264VAC 254 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 87%| 89%| 90%| 90%
AC CURRENT (Typ.)| 4A/230VAC
INRUSH CURRENT (Typ.)| 90A/230VAC
LEAKAGE CURRENT| <1mA / 240VAC
PROTECTION
| ****
OVER LOAD
| 110 ~ 140% rated output power| 130 ~ 180% rated output power| 120 ~ 160%
rated output power
12-36V Hiccup mode, recovers automatically after fault condition is removed
48V Shut down and latch off o/p voltage, re-power on to recover
OVER VOLTAGE
| 13.8 ~ 16.2V| 27.6 ~ 32.4V| 41.4 ~ 46.8V| 55.2 ~ 64.8V
12-36V Hiccup mode, recovers automatically after fault condition is removed
48V Shut down and latch off o/p voltage, re-power on to recover
OVER TEMPERATURE| 12-36V Shut down O/P voltage, recovers automatically
after temperature goes down 48V Shut down and latch off o/p voltage, re-power
on to recover
ENVIRONMENT
| WORKING TEMP.| -30 ~ +60℃ (Refer to output load derating curve)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -30 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.05%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC
| SAFETY STANDARDS| UL 62368-1,IEC 62368-1,GB 4943.1,EAC TP TC 004
approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25℃/
70% RH
EMC EMISSION| Refer to EN55022 (CISPR22) class A, EAC TP TC 020
EMC IMMUNITY| Refer to EN61000-4-5;light industry level, EAC TP TC 020
OTHERS
| MTBF| 2396.7K hrs min. Telcordia SR-332 (Bellcore) 321Khrs
min. MIL-HDBK-217F (25℃)
DIMENSION| 220.413048mm (LWH)
PACKING| 0.9Kg; 9 pcs/11Kg/0.63CUFT
NOTE|
- All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
- Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0. 1uf & 47uf parallel capacitor.
- Tolerance: includes set up tolerance, line regulation and load regulation.
- The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft).
- Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Block Diagram
Derating Curve
Static Characteristics
Mechanical Specification
- Case No. 230
- Unit: mm
Terminal Pin No. assignment
Pin No. | Assignment | Pin No. | Assignment |
---|---|---|---|
1 | AC/L | 4~6 | DC OUTPUT -V |
2 | AC/N | 7~9 | DC OUTPUT +V |
3 | FG |
Installation
- ERP-350 is designed for outdoor application and should be installed in the place with shelter.
- ERP-350 should be installed in an upright position, leaning forward, backward or lay flat are not allowed.
- For heat dissipation, at least 10cm installation distance around the PSU should be kept, shown as below:
User’s Manual
Documents / Resources
| MEAN
WELL ERP-350 Series 350W Single Output Switching Power
Supply
[pdf] Owner's Manual
ERP-350 Series 350W Single Output Switching Power Supply, ERP-350 Series, 350W
Single Output Switching Power Supply, Single Output Switching Power Supply,
Output Switching Power Supply, Switching Power Supply, Power Supply, Supply
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>