JBM 54482 Ultrasonic Parts Cleaner Instruction Manual
PRODUCT’S PRESENTATION
This machine allows you to clean parts by emitting ultrasound. Through the
cavitation process, these ultrasounds create microsco- pic bubbles in the
cleaning liquid. The effect achieved is an exhaustive and precise clea- ning
of the parts to be cleaned. Therefore, this cleaner is especially suitable for
cleaning parts with complex shapes.
It has a basket to place the pieces, as well as a timer and temperature
regulator to adjust the cleaning mode.
SAFETY INSTRUCTIONS
Read carefully this owner’s ma- nual before using the product.
Failure to comply with these ins- tructions could result in personal injury
and/or damage
to the product.
Please keep the instructions for future referen- ce.
Do not use if the tank is empty as this could damage the ultrasonic generator.
The water level should not be less than 2/3. Be careful when opening the lid.
It is recommended to use special water-solu- ble detergents for ultrasonic
cleaning machi- nes.
Do not use flammable liquids such as alcohol or gasoline, as heat and
vibration could cause a fire.
TECHNICAL SPECIFICATIONS
Ultrasonic power: 600W Heating power: 500W Tank capacity: 30L
Ultrasonic frequency: 40KHz Timer: 1~60 min.
Power supply: 200~240V (50Hz) Number of transductors: 10 Heater: 0~80ºC
Material: Stainless steel SUS304 Tank dimensions: 500x300x200mm Dimensions:
530x325x325mm Weight: 14.5Kg
PARTS LIST
No. | Description |
---|---|
1 | Lid |
2 | Tank |
3 | Drainage valve |
4 | Ventilation holes |
5 | Foot |
6 | Control panel |
7 | Temperature indicator |
8 | Temperature regulator |
9 | Time indicator |
10 | Time regulator |
11 | DEGAS function indicator |
12 | Power indicator |
13 | Power on/off switch |
14 | Fuse |
15 | Power supply connector |
ASSEMBLY
Add cleaning fluid into the tank.
Note: The liquid level must be at least 2/3 of the tank capacity.
Plug in the power cord and press the on/offbutton.
The power indicator on the control panel will illuminate.
OPERATION
Ultrasonic cleaning
To activate ultrasonic cleaning, turn the timer to set the cleaning duration.
The light will flash while cleaning is in progress. Once finished, the light
will remain steady
If you select ∞, cleaning will be performedcontinuously.
Heating
Turn the temperature regulator to set the tem- perature at which you want to
clean.
While the set temperature is not reached, thelight will flash.
Once the temperature is reached, the light will remain on.
DEGAS function
This feature provides more effective cleaning.
With this function the cleaner will intermittently stop and start the emission
of ultrasound. This will reduce the amount of air present in the li- quid and
help the machine achieve a greater cleaning effect.
To activate the DEGAS function, briefly pressthe timer button.
The DEGAS function indicator light will turn on.
To stop the DEGAS function, press the button again.
Turning off
To turn off the machine, press the on/off bu- tton.
Unplug the power cord. Empty the cleaning fluid tank. Using a cloth, wipe the tank.
CLEANING
Clean the tank at least once a week
TROUBLESHOOTING
No. | Problem | Possible causes | Solution | Notes |
---|---|---|---|---|
1 | The ultrasound function does not work. | Power cable not con- nected | ||
correctly. | Compruebe la conexión de la alimentación. Susti- tuya el fusible. |
Sustituya la
placa base.
|
2| The timer does
not work.
| Defective timer.| Replace the timer.|
3| The heating does not work.| Check that the hea- ting element connec- tion
is correct.| Conecte correctamente el elemento calefactor a la placa base
(conector
PTC). Sustituya el fusible.
| It is recom- mended
to clean at
50-60ºC.
4| The temperature control does not
work.
| Thermostat not con- nected correctly.| Conecte correctamente el termostato. Sustituya el
termostato.
|
5| The machine does not clean properly.| Incorrect fluid level.| Ponga la
cantidad de líquido correcta. Ponga la temperatura correcta. Sustituya el
líquido por
uno apropiado.
| It is recom- mended
to clean at 50-60ºC.
6| Electrical failure.| The ground wire is not connected correctly.| Make sure the machine ground wire is properly connected to the power
cord.
|