JBM 54342 Parts Cleaner Machine with Thermostat Instruction Manual
- June 1, 2024
- JBM
Table of Contents
INSTRUCTION MANUAL
54342 PARTS CLEANER MACHINE WITH THERMOSTAT
PRODUCT’S PRESENTATION
Machine designed for perfect washing of dirty parts.
It includes a pneumatic gun to clean with solvent and can also be used to dry
the parts using compressed air.
Thanks to its closed cabin, the operator is completely protected from splashes
and odour of the solvent.
It has a thermostat with which you can adjust the temperature level of the
cleaning liquid and light inside the tank for better visualization.
SAFETY INSTRUCTIONS
The owner’s manual is a crucial resource for understanding product safety,
warnings, and precautions, as failure to follow could lead to personal injury
or property damage.
WARNING! Maintain a safe working environment by controlling bench
deviation, keeping work areas clean, keeping children away, using appropriate
tools, using organic cleaning solvent, and using protective gloves.
Before servicing or changing accessories, disconnect parts washer.
Make sure the heating switch is OFF before turning on the machine.
Do not activate the heating if the solvent volume is less than 8 liters.
Do not use the machine if the lid is open.
Do not use solvent which ignition temperature is lower than 120ºC.
Do not set the operating temperature above 50ºC.
TECHNICAL SPECIFICATIONS
Tank capacity: | 8-14L |
---|---|
Air flow: | 70-120 PSI@5CFM |
Cleaning agent flow rate: | 0.8L/min |
Thermostat maximum temperature: | 50ºC |
Tank dimensions: | 74x56x45.2cm |
Dimensions: | 790x1710x610mm |
Weight: | 46Kg. |
PARTS LIST
No. | Description | Function |
---|---|---|
1 | Digital temperature control | Allows you to adjust the temperature level. |
2 | Heating switch | Press to heat the solvent. |
3 | Air pressure gauge | Shows air pressure. |
4 | Air regulator | Allows you to adjust the air pressure depending on the type |
of parts you are going to wash.
5| Power supply switch| Press to turn on the light and the fan.
6| Cleaning gun trigger| Press to expel solvent.
7| Solvent valve| Open the valve to let out compressed air
No. | Description | Function |
---|---|---|
9 | Solvent drainage | Open the valve to empty the solvent. |
10 | Solvent hose | Connect the solvent tank to the gun. |
11 | Quick plug | Connection to heating. |
12 | Solvent level indicator | Allows you to observe if the solvent level is |
sufficient.
13| Fixed bolt| Fixes the solvent tank to the structure.
No. | Description | Function |
---|---|---|
14 | Air inlet | Allows you to connect a 8mm diameter compressed air tube. |
ASSEMBLY
Put the tank on the floor.
Connect the 2 support legs to the tank cabinet using 4 M12 screws and flat
washers.
Attach the cross bar to the support legs using 2 M10 screws and flat washers.
Attach the adjustable feet to the bottom of the support legs.
Turn over the machine and adjust the height of adjustable feet.
OPERATION
Solvent adding
Open cabinet cover.
Add solvent through the web tray.
Note: Put 8 to 14 liters.
Compressed air connection
Connect the air compressor φ8 hose to the quick fitting at the bottom of the
cabinet.
Adjust appropriate air pressure based on the parts type you are washing.
Light and fan
Plug the parts washer machine to the electric power supply.
Press the Power Supply switch to turn on the light and activate the fan.
Solvent temperature setting
Press the OK button in the digital temperature controller.
Then, press the SET button.
Press the up/down buttons to adjust the temperature.
Heating activation
To heat the solvent, press the heating switch.
Cleaning
Put parts into the machine and close the cabinet.
Use the cleaning gun to wash and air drying.
Open the air valve. Press the gun trigger to expel the solvent. Finishing
Turn off heating.
Turn off the power supply.
MAINTENANCE
Disconnect power and compressed air before the maintenance.
Solvent Changing
Replace the solvent when needed.
Open the solvent drain valve to remove dirty solvent from the tank.
If you want to remove the entire tank, unscrew the screw at the bottom of the
tank.
Clean the solvent filter screen regularly.
TROUBLESHOOTING CHART
Symptoms (s) | Possible Causes (s) | Corrective Action (s) |
---|---|---|
Cleaning gun only expels air, not solvent anymore. | Cleaning switch is OFF. |
Not enough solvent.
Absorption pipe is blocked.| Turn it on.
Add more solvent into the tank Check and clean the absorption pipe.
Light does not work but fan still works.| Light is broken.| Replace with a new
one.
Fan does not work but light still works.| Fan is broken.| Replace with a new
one.
Temperature controller display does not function correctly.| Wrong plug
connection.| Check the connection.
Temperature cannot reach the temperature set.| Not enough solvent. Heating
switch is off. Heating tube is broken.| Add more solvent
Turn on the Heating On/Off Switch Replace with a new heating tube
PARTS LIST (EXPLODED VIEW)
N.O. | DESCRIPTION | QTY. | N.O. | DESCRIPTION | QTY |
---|---|---|---|---|---|
1 | Front Panel | 1 | 13 | Back Door Rod | 2 |
2 | Pin | 2 | 14 | Fan Cover | 1 |
3 | Hinge Axis | 2 | 15 | Front Door Rod | 2 |
4 | Cleaning Tank | 1 | 16 | Ventilated Fan | 1 |
5 | Cabinet Holder | 1 | 17 | Cleaning Gun | 1 |
6 | Web | 1 | 18 | Cabinet | 1 |
7 | Filter Screen | 1 | 19 | Back panel | 1 |
8 | LED Light | 1 | 20 | Side Support | 4 |
9 | Light Hoop | 2 | 21 | Side panel | 2 |
10 | Cabinet cover | 1 | 22 | Cross bar | 1 |
11 | Gloves | 1 pair | 23 | Support leg | 2 |
12 | Gloves Hoop | 2 | 24 | Adjustable foot | 4 |
www.jbmcamp.com
JBM CAMPLLONG, S.L.U.
CIM La Selva – Ctra. Aeropuerto km. 1,6
Nave 2.2 – CP 17185 Vilobí d’Onyar – GIRONA
jbm@jbmcamp.com
Tel. +34 972 405 721
Fax. +34 972 245 437
Read User Manual Online (PDF format)