PRODUCT’S PRESENTATION

Machine designed for perfect washing of dirty parts.
It includes a pneumatic gun to clean with solvent and can also be used to dry the parts using compressed air.
Thanks to its closed cabin, the operator is completely protected from splashes and odour of the solvent.
It has a thermostat with which you can adjust the temperature level of the cleaning liquid and light inside the tank for better visualization.

SAFETY INSTRUCTIONS

The owner’s manual is a crucial resource for understanding product safety, warnings, and precautions, as failure to follow could lead to personal injury or property damage.
WARNING! Maintain a safe working environment by controlling bench deviation, keeping work areas clean, keeping children away, using appropriate tools, using organic cleaning solvent, and using protective gloves.
Before servicing or changing accessories, disconnect parts washer.
Make sure the heating switch is OFF before turning on the machine.
Do not activate the heating if the solvent volume is less than 8 liters.
Do not use the machine if the lid is open.
Do not use solvent which ignition temperature is lower than 120ºC.
Do not set the operating temperature above 50ºC.

TECHNICAL SPECIFICATIONS

Tank capacity: 8-14L
Air flow: 70-120 PSI@5CFM
Cleaning agent flow rate: 0.8L/min
Thermostat maximum temperature: 50ºC
Tank dimensions: 74x56x45.2cm
Dimensions: 790x1710x610mm
Weight: 46Kg.

PARTS LIST

JBM 54342 Parts Cleaner Machine with Thermostat - PARTS
LIST

No. Description Function
1 Digital temperature control Allows you to adjust the temperature level.
2 Heating switch Press to heat the solvent.
3 Air pressure gauge Shows air pressure.
4 Air regulator Allows you to adjust the air pressure depending on the type

of parts you are going to wash.
5| Power supply switch| Press to turn on the light and the fan.
6| Cleaning gun trigger| Press to expel solvent.
7| Solvent valve| Open the valve to let out compressed air

JBM 54342 Parts Cleaner Machine with Thermostat - PARTS LIST
1

No. Description Function
9 Solvent drainage Open the valve to empty the solvent.
10 Solvent hose Connect the solvent tank to the gun.
11 Quick plug Connection to heating.
12 Solvent level indicator Allows you to observe if the solvent level is

sufficient.
13| Fixed bolt| Fixes the solvent tank to the structure.

No. Description Function
14 Air inlet Allows you to connect a 8mm diameter compressed air tube.

ASSEMBLY

Put the tank on the floor.
Connect the 2 support legs to the tank cabinet using 4 M12 screws and flat washers.
Attach the cross bar to the support legs using 2 M10 screws and flat washers.
Attach the adjustable feet to the bottom of the support legs.
Turn over the machine and adjust the height of adjustable feet.

JBM 54342 Parts Cleaner Machine with Thermostat -
ASSEMBLY

OPERATION

Solvent adding
Open cabinet cover.
Add solvent through the web tray.
Note: Put 8 to 14 liters.
Compressed air connection
Connect the air compressor φ8 hose to the quick fitting at the bottom of the cabinet.
Adjust appropriate air pressure based on the parts type you are washing.
Light and fan
Plug the parts washer machine to the electric power supply.
Press the Power Supply switch to turn on the light and activate the fan.
Solvent temperature setting
Press the OK button in the digital temperature controller.
Then, press the SET button.
Press the up/down buttons to adjust the temperature.
Heating activation
To heat the solvent, press the heating switch.
Cleaning
Put parts into the machine and close the cabinet.
Use the cleaning gun to wash and air drying.
Open the air valve. Press the gun trigger to expel the solvent. Finishing
Turn off heating.
Turn off the power supply.

MAINTENANCE

Disconnect power and compressed air before the maintenance.
Solvent Changing
Replace the solvent when needed.
Open the solvent drain valve to remove dirty solvent from the tank.

If you want to remove the entire tank, unscrew the screw at the bottom of the tank.
Clean the solvent filter screen regularly.

TROUBLESHOOTING CHART

Symptoms (s) Possible Causes (s) Corrective Action (s)
Cleaning gun only expels air, not solvent anymore. Cleaning switch is OFF.

Not enough solvent.
Absorption pipe is blocked.| Turn it on.
Add more solvent into the tank Check and clean the absorption pipe.
Light does not work but fan still works.| Light is broken.| Replace with a new one.
Fan does not work but light still works.| Fan is broken.| Replace with a new one.
Temperature controller display does not function correctly.| Wrong plug connection.| Check the connection.
Temperature cannot reach the temperature set.| Not enough solvent. Heating switch is off. Heating tube is broken.| Add more solvent
Turn on the Heating On/Off Switch Replace with a new heating tube

PARTS LIST (EXPLODED VIEW)

JBM 54342 Parts Cleaner Machine with Thermostat - PARTS LIST
3

N.O. DESCRIPTION QTY. N.O. DESCRIPTION QTY
1 Front Panel 1 13 Back Door Rod 2
2 Pin 2 14 Fan Cover 1
3 Hinge Axis 2 15 Front Door Rod 2
4 Cleaning Tank 1 16 Ventilated Fan 1
5 Cabinet Holder 1 17 Cleaning Gun 1
6 Web 1 18 Cabinet 1
7 Filter Screen 1 19 Back panel 1
8 LED Light 1 20 Side Support 4
9 Light Hoop 2 21 Side panel 2
10 Cabinet cover 1 22 Cross bar 1
11 Gloves 1 pair 23 Support leg 2
12 Gloves Hoop 2 24 Adjustable foot 4

www.jbmcamp.com
JBM CAMPLLONG, S.L.U.
CIM La Selva – Ctra. Aeropuerto km. 1,6
Nave 2.2 – CP 17185 Vilobí d’Onyar – GIRONA
[email protected]
Tel. +34 972 405 721
Fax. +34 972 245 437

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

JBM User Manuals

Related Manuals